• Title/Summary/Keyword: Unified

Search Result 3,623, Processing Time 0.03 seconds

Performance Analysis of UPQC(Unified Power Quality Conditioner) with Compensation Capability for Voltage Interruption (순간정전에 대한 보상능력을 갖는 UPQC(Unified Power Quality Conditioner)의 성능해석)

  • 김희중;배병열;한병문;설승기;조보형
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.5
    • /
    • pp.279-286
    • /
    • 2003
  • A new UPQC(unified power quality conditioner), which consists of series inverter, shunt inverter, dc/dc converter, and energy storage, is proposed. The proposing UPQC can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance, and voltage interruption. The control strategy for the proposing UPWQC was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the EMTDC/PSCAD simulation and the experimental work with the hardware prototype. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems or industrial power systems and can be utilized for the custom power device in the future distribution system.

Simulation Model for Dynamic Performance Analysis of UPFC (UPFC의 동적 성능해석을 위한 시뮬레이션 모형)

  • Han, Byung-Moon;Choi, Dae-Gil;Shin, Ik-Shang
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.479-481
    • /
    • 1996
  • This paper describes a simulation model to analyze the dynamic performance of Unified Power Flow Controller which ran flexibly adjust the active and reactive power flow through the ac transmission line. An equivalent circuit to analyze the basic principle for the whole system operation was developed and a control system for the Unified Power Flow Controller was derived using vector control method. A computer simulation model with EMTP code was also conceived to evaluate the performance of the Unified power Flow Controller. The simulation results show that Unified Power flow Controller is very effective for controlling the power flow and damping the subsynchronous resonance in the power system.

  • PDF

Unified Non-iterative Algorithm for Principal Component Regression, Partial Least Squares and Ordinary Least Squares

  • Kim, Jong-Duk
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.2
    • /
    • pp.355-366
    • /
    • 2003
  • A unified procedure for principal component regression (PCR), partial least squares (PLS) and ordinary least squares (OLS) is proposed. The process gives solutions for PCR, PLS and OLS in a unified and non-iterative way. This enables us to see the interrelationships among the three regression coefficient vectors, and it is seen that the so-called E-matrix in the solution expression plays the key role in differentiating the methods. In addition to setting out the procedure, the paper also supplies a robust numerical algorithm for its implementation, which is used to show how the procedure performs on a real world data set.

  • PDF

Unified Design Method for Toroidal Transformer and its Optimal Algorithm (토로이드형 변압기의 일관성있는 설계법과 그 최적화 알고리즘)

  • 김주홍;이광직
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.3
    • /
    • pp.78-83
    • /
    • 1991
  • This study proposes a unified method to design toroidal transformer and its optimal design algorithm. This unified design method was derived from the fundamental equation of power on the basis of electromagnetic energy of a core and the definition of three parameters(K1, K2, KW) that influence the form of a core and the ratio of a core and coil. Accordingly this design method condenses the whole data for design of toroidal transformer to a standard variable which is the inner diameter of a core. The minimal cost, weight and volume values of the transformer were computed by means of the algorithm to search the optimal values of the parameters. Furthermore, through the CAD, the efficiency of this unified design method and optimal algorithm proposed in this paper was confirmed.

  • PDF

Design of Unified Trench Gate Power MOSFET for Low on Resistance and Chip Efficiency (낮은 온저항과 칩 효율화를 위한 Unified Trench Gate Power MOSFET의 설계에 관한 연구)

  • Kang, Ey-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.10
    • /
    • pp.713-719
    • /
    • 2013
  • Power MOSFET operate voltage-driven devices, design to control the large power switching device for power supply, converter, motor control, etc. We have optimal designed planar and trench gate power MOSFET for high breakdown voltage and low on resistance. When we have designed $6,580{\mu}m{\times}5,680{\mu}m$ of chip size and 20 A current, on resistance of trench gate power MOSFET was low than planar gate power MOSFET. The on state voltage of trench gate power MOSFET was improved from 4.35 V to 3.7 V. At the same time, we have designed unified field limit ring for trench gate power MOFET. It is Junction Termination Edge type. As a result, we have obtained chip shrink effect and low on resistance because conventional field limit ring was convert to unify.

Temperature control of a batch polymerization reactor using nonlinear predictive control algorithm (비선형 예측제어 알고리즘을 이용한 회분식 중합 반응기의 온도제어)

  • 나상섭;노형준;이현구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1000-1003
    • /
    • 1996
  • Nonlinear unified predictive control(UPC) algorithm was applied to the temperature control of a batch polymerization reactor for polymethylmethacrylate(PMMA). Before the polymerization reaction is initiated, the parameters of the process model are determined by the recursive least squares(RLS) method. During the reaction, nonlinearities due to generation of heat of reaction and variation of heat transfer coefficients are predicted through the nonlinear model developed. These nonlinearities are added to the process output from the linear process model. And then, the predicted process output is used to calculate the control output sequence. The performance of nonlinear control algorithm was verified by simulation and compared with that of the linear unified predictive control algorithm. In the experiment of a batch PMMA polymerization, nonlinear unified predictive control was implemented to regulate the temperature of the reactor, and the validity of the nonlinear model was verified through the experimental results. The performance of the nonlinear controller turned out to be superior to that of the linear controller for tracking abrupt changes in setpoint.

  • PDF

A unified systeolic array for computation of the 2D DCT/DST/DHT (2D DCT/DST/DHT 계산을 위한 단일화된 시스톨릭 어레이)

  • 반성범;박래홍
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.2
    • /
    • pp.103-110
    • /
    • 1996
  • In this paper, we propose a unified systolic array for the computation of the 2D discrete cosine transform/discrete sine transform/discrete hartley transform (DCT/DST/DHT). The unified systeolic array for the 2D DCT/DST/DHT is a generalization of the unified systolic array for the 1D DCT/DST/DHT. In order to calculate the 2D transform, we compute 1D transforms along the row, transpose them, and obtain 1D transforms along the column. When we compare the proposed systolic array with the conventional method, our architecture exhibits a lot of advantages in terms of latency, throughput, and the number of PE's. The simulation results using very high speed integrated circuit hardware description language (VHDL), international standard language for hardware description, show the functional validity of the proposed architecture.

  • PDF

New Unified bounds for the solution of the Lyapunov matrix equation for Decentralized Singularly Perturbed Unified System (분산 특이변동 시스템의 리아푸노프 행렬 방정식의 해에 대한 단일 경계치)

  • Lee, Dong-Gi;Oh, Do-Chang
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.1
    • /
    • pp.34-42
    • /
    • 2009
  • In this paper, new bounds for the solution of the unified Lyapunov matrix equation for decentralized singularly perturbed systemare obtained, and some of the existing works using deficient assumptions are also generalized.

Implementation of the High Performance Unified PID Position Controller for Linear Motor Drive with Easy Gain Ajustment Part I - Feature of the Unified PID Position Controller (이득 설계가 간단한 선형전동기 구동용 고성능 통합 PID 위치제어기 구현 제1부: 통합 PID 위치제어기 특성)

  • Kim, Jun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.187-194
    • /
    • 2002
  • Recently, the application of the linear machine far industrial field is remarkable increased, especially for the gantry machine, machine tool system and CNC. In these application fields, high dynamics position control performance Is essentially required in both the steady and the transient state. This pacer presents simple but powerful position control loop based on traditional PID controller. The presented position control algorithm, named 'Unified PID Position Controller'has great features for the linear machine drives such as no over-shoot phenomena and simple gain tuning strategy. Through the experimental results with commercial linear motors, it is shown that the proposed algorithm has excellent dynamics suitable fur linear motions.

Unified Controller for 100kVA Emergency Generator (100kV급 비상발전기용 통합제어기)

  • Jeong, C.Y.;Cho, J.G.;Baek, J.W.;Lee, J.J.;Kim, Y.J.;Yoo, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2801-2803
    • /
    • 1999
  • An unified controller for emergency generator is presented to control AVR and Governor and l00kVA power conditioner. This controller is operated to compensate current harmonics and asymmetries caused by nonlinear load and unbalance loads. The power conditioner shapes the source current sinusoidal in phase with source voltage and allows the generator to maximum power even to the single phase load. Also this power conditioner allows that three phase generator synchronizes with single phase main source and load sharing. An l00kVA generator system was built and the unified controller is realized with DSP(TMS320C32PCMA). Experimental results for many load conditions are presented to verify the performance of the unified controller.

  • PDF