접지방식이 상이한 철도배전계통의 연장급전을 위한 전기적 특성분석 (Analysis of electric characteristics for extension power supply between different grounding railway distribution system)

  • 정호성;한문섭;이장무;권삼영;박현준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.736-741
    • /
    • 2005
  • This paper presents electric characteristics analysis and safe configuration for extension power supply between existent 6.6kV ungrounded distribution system and establishment and improvement 22.9kV direct grounding distribution system. For this, we model 6.6kV ungrounded and 22.9kV direct grounding distribution system of urban underground, ground region. and rural electrical, unelectrical region using PSCAD/EMTDC and analyze voltage drop, charging current, ground and short fault through simulation. To analyze electric characteristics of extension power supply, we simulate extension power supply of overhead line of 6.6kV ungrounded system and underground line of 22.9kV direct grounding system of rural electrical region and propose operation condition for safe extension power supply through result of analysis. Characteristics of voltage drop, charging current, ground and short fault appear almost similarly with electrical characteristic of direct power supply. However, because unbalance of phases may cause relay's malfunction of ungrounded system and ground fault current of direct grounding system may demage facilities of ungrounded system, we propose safe system configuration such as impedance grounding system of neutral point.

  • PDF

비접지 배전선로의 고장상 판별 알고리즘 개발 (A Faulted Phase Discrimination Algorithm in Ungrounded Distribution System)

  • 이덕수;임성일;최면송;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권2호
    • /
    • pp.114-120
    • /
    • 2003
  • According to the use of distribution automation systems, the function to find or to search a fault phase is necessary for automatic switches in a distribution substation. In this paper, two algorithms are developed to fine the fault circuit and the fault phase for the automatic switches in substation with ungrounded power system. One is the fault circuit searching method using the zero sequence voltage at the bus and zero sequence current of circuit current and the other is to find the fault phase using the line voltage and zero sequence current. The developed algorithms are tested in the case study simulations. An ungrounded power system is modeled by EMTP as a case study system. The developed algorithms are tested in the case study simulations and each shows correct results.

선택지락보호계전기 오.부동작에 관한 연구 (Study on the Ground Fault Protection in 6.6KV Ungrounded Power System SGR Malfunction or Non-Tripping)

  • 김병태;이달우;전명수
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.296-301
    • /
    • 2008
  • This paper presents a study on the ground fault protection in 6.6KV ungrounded power system relay(SGR) malfunction or non-tripping. Ground test had made on 6.6KV HV(high voltage) system, Some of domestic and oversea's SGR products are different from their own specific characteristics. This study on the ground protection relay 6.6KV power supply system is focused to protect human.

A Modified Selective Ground Relay for Ungrounded Distribution Systems

  • Nam Soon-Ryul;Kang Sang-Hee;Park Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.16-22
    • /
    • 2006
  • Selective ground relays (SGRs) are useful fur distinguishing a faulted feeder from the sound feeders in ungrounded systems. However, they sometimes mis-operate due to human or device errors. Particularly, the reversed polarity of zero-sequence current transducers (ZCTs) is the most frequent cause of mis-operation. This paper presents a modified SGR for reducing the probability of mis-operations caused by the reversed polarity of ZCTs. The modification is achieved by introducing an adaptive time delay, which depends on the magnitude of the zero-sequence current and the phase angle deviation from the reference. The modified SGR was successfully demonstrated on a sample ungrounded system without mis-operation.

비접지 배전계통에서 고장구간 검출 및 복구 알고리즘 (Fault Section Detection Scheme in Ungrounded Distribution System)

  • 위페이;최면송;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.487-488
    • /
    • 2007
  • Fault section detection and service restoration is very important in ungrounded distribution system. Techniques currently used to track down faults are time consuming and cumbersome. A new scheme is developed based on communication technology, and the simulation result shows that the method can satisfy the requirement proposed.

  • PDF

DC 비접지 급전계통 선택차단형 통합보호계전기 시뮬레이터 개발 및 알고리즘 테스트 (Development of a Simulator and Algorithm Test for Selective-breaking Integrated Protective Relay for Ungrounded DC Traction Power Supply System)

  • 안태풍;윤준석;정태영;김인웅;정호성
    • 전기학회논문지
    • /
    • 제61권6호
    • /
    • pp.899-904
    • /
    • 2012
  • In recent years, a lot of research was done for earth fault protection in ungrounded dc power supply system. As a result, selective-breaking integrated protective relaying system is developed in progress and is currently field-testing are planned. Algorithm on a PC using PSCAD done a lot of testing before performing field tests, but in this study developed algorithms and functions needed to determine whether they were operating normally. Therefore, simulated system is similar to the actual situation was required and made. selective-breaking algorithm verification and validation was performed with simulator.

비접지 배전계통 지락고장 검출 알고리즘 및 프로그램 개발 (Development of Algorithm and Program for the Ground Fault Detection in Ungrounded Distribution Power System)

  • 박소영;신창훈
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2619-2627
    • /
    • 2009
  • 비접지 배전계통에서 전체고장의 약 70%를 차지하는 지락고장 발생시에는 지락전류가 작아 검출이 어렵지만 고장상태로 전원 공급을 지속할 경우 사고 파급 및 기기 소손을 유발할 가능성이 있기 때문에 지락고장 처리는 매우 중요하다. 본 논문에서는 GPT(접지형 계기용 변압기, Ground Potential Transformer)에서 감지하는 영상전압 신호를 이용하여 고장선로를 검출하고, 비상시 연계선로를 이용하여 정전구역을 복구하기 위해 평상시 개폐기가 열려 있는 상태로 배전선로 사이를 연결하는 상시개방점을 이동하며 각 구간을 차례로 분리하면서 GPT 신호의 사라짐 여부를 감시하여 고장구간을 검출하는 방법을 제안한다. 고장구간 탐색 시 전체 정전이 없고, 고장구간 검출과 건전구간 복구가 동시에 가능하며 다양한 형태의 배전계통 구성에 적용 가능하다는 점에서 효율적이다. 본 논문에서 제안하는 고장처리 방법을 프로그램으로 개발하여 베트남 배전자동화 시범사업에 적용함으로써 알고리즘 및 프로그램의 적정성을 검증하였다.

비접지 배전 계통에서 지락사고 시 고장구간 분리 및 복구를 위한 새로운 알고리즘 (A New Algorithm of The Line to Ground Fault Section Isolation & Restoration in Ungrounded Distribution Power System)

  • 최인선;최면송;임성일;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권10호
    • /
    • pp.550-555
    • /
    • 2004
  • Fault section isolation and service restoration are very important for function of DAS. In Japan, a progressive protection method is used for the line to ground fault section isolation and service restoration. But the progressive protection method has a drawback that the customer will experience outage time and that the rate in use of the feeder is not over 50%. This paper presents a new Service Restoration Algorithm which is for the line to ground fault section isolation and service restoration method for a ungrounded distribution system. If the proposed algorithm is used, the rate in use of the feeder can improve than before because a distribution system can change multi connection of feeder and the customer's outage time can be reduced. The proposed algorithm has been successfully tested in a distribution system.

도시철도 직류 비접지 급전계통에서의 선택 지락보호시스템의 성능평가 (An Evaluation of Selective Grounding Fault Protective Relaying Technique Performance on the Ungrounded DC Traction Power Supply System)

  • 정호성;김주욱;신승권;김형철;안태풍;윤준석
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1964-1969
    • /
    • 2012
  • This paper presents to verify the selective grounding fault protective relaying technique for the ungrounded DC traction power supply system. This system selectively blocks fault section when grounding fault occurred. In order to perform this verification, field test facilities have been installed on Oesam substation and Worldcup-Stadium substation, and field test process has been suggested. Also, selective grounding fault protective relaying components and rail voltage reduction device have been tested with the various trial examinations. In order to compare and evaluate performance of the selective grounding fault protective relaying function, field test system was modeled and the system fault simulation results were compared and evaluated with the field test result. Performance of selective grounding fault protective relaying function was evaluated with the above-mentioned process, and the fact that the system recognizes fault section irrespective of insulation between rail and ground and fault resistance from grounding fault.

비접지 배전계통에서 영상전류 위상 비교에 의한 고장구간 검출 방법 (A Fault Section Detection Method for Ungrounded System Based on Phase Angle Comparison of Zero-Sequence Current)

  • 양하;최면송;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.31-32
    • /
    • 2007
  • In this paper, a fault section detection method is proposed for ungrounded system in the case of a single line-to-ground fault. A conventional method is used for faulted feeder selection according to the angular relationship between zero-sequence currents of the feeders and zero-sequence voltage of the system. Fault section detection is based on the comparison of phase angle of zero-sequence current. Proposed method has been testified in a demo system by Matlab/Simulink simulations. Based on Distribution Automation System(DAS), Feeder Remote Terminal Unit(FRTU) is used to collect those necessary data, at present a demo system is under developing using Manufacturing Message Specification (MMS) in IEC61850 standard.

  • PDF