• Title/Summary/Keyword: Underground Structures

Search Result 976, Processing Time 0.024 seconds

Analysis of Underground Box Structures with Inelastic Soil Spring (비탄성 지반 스프링을 이용한 지하 구조물의 해석)

  • Oh, Chi-Woong;Chung, Jae-Hoon;Yhim, Sung-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.91-96
    • /
    • 2002
  • There are many methods for analyzing underground box structures. One is the method of Iterative removal of tensional spring. The other is the method of modeling of ground to 8-node elastic-plastic planar element. In this study, We use inelastic soil spring element for analyzing underground box structures. First, if N-value is over 50, the results of inelastic soil spring method is the same as the method of 8-node planar element in last stage. Second, as N is increasing, element forces in two methods are generally decreasing. Third, as N-value is increasing, element forces in two method are generally decreasing and displacement has decreasing incline. This is the same as the force-displacement curve of general underground structures.

Exploration of underground utilities using method predicting an anomaly(II) - field application (전기비저항을 이용한 지하매설물 탐사(II) - 현장실험 중심으로)

  • Ryu, Hee Hwan;Cho, Seon Ah;Kim, Kyoung Yul;Cho, Gye Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.449-461
    • /
    • 2017
  • The uncertain existence and insufficient information of underground structures, such as pipe lines and cable tunnels, is causing many problems related to route plan, design, construction of new underground structures. The theoretical equations that is able to predict the location, size, and direction of underground structures through electric field analysis are suggested at the previous study (Ryu., 2015). Three field tests were performed for predicting the location, size, and direction of underground structures and the existence and size of sink-hole. Prediction results were reflected at the design and follow-up measures were performed.

Analysis of dynamic behavior for underground structures under earthquake loading (지진하중을 받는 지하구조물에 대한 동적 거동 해석)

  • Park, Seong-Yong;Lee, Jae-Jin;Choi, Seung-Ho;Kim, Soo-Il;Park, Inn-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.2
    • /
    • pp.205-217
    • /
    • 2007
  • The behavior characteristics of underground structures are reported as they are not affected by their dynamic characteristics such as surface structures, but by dynamic characteristics of soil and rock surrounding the underground structures. Therefore, dynamic behavior of surrounding soil and rock dominates the dynamic behavior of the underground structure. The purpose of this paper is to analyze the dynamic response (longitudinal deformation and ovaling deformation) of the underground structure under earthquake loading. The dynamic responses of the underground structures were evaluated with varying earthquake conditions, soil conditions, and structural conditions using conventional closed-form solution of seismic behavior of underground structure. In addition, shaking table tests were conducted to simulate the earthquake loading and the dynamic behavior of the model was analyzed.

  • PDF

An Experimental Study on the Waterproofing Performance of Expansion Equipment for Underground Structures (지하구조물용 신축이음장치의 방수성능에 관한 실험연구)

  • Lee, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4302-4309
    • /
    • 2012
  • Underground structures without the expansion joint in the settled intervals, the underground structures may suffer from structural crack and the water leakage thereby resulting in the occurance of the efflorescence. In this study, the performance of new expansion joint used in underground structures were verified. The spacing of expansion joint was defined by the finite element analysis. Expansion length, resistance and waterproofing performance of developed expansion joint were confirmed by experiment.

Ground Movement Analysis by Field Measurements (현장계측에 의한 지반거동 분석)

  • Chon, Yong-Back;Cho, Sang-Wan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.8 no.3
    • /
    • pp.161-168
    • /
    • 2005
  • This study is analysis for adjacent structures and ground movement by deep excavation work. Underground Inclinometer has shown that deformation of increment is minor within to allowable limit. According to the measurements result of slope and crack for adjacent structures, a detached house showed bigger than hospital structure to deformation of increment. Variation of underground water level didn't effect so much to ground and adjacent structures movement because underground water flows in rock and didn't give the water press to propped walls. Measurement data of strut variation is within tolerance limit. Because excavation site's wall was strengthened suitably. This study will contribute in establishment of measurement standard and information-oriented construction during deep excavation in multi-layered ground including rock masses.

  • PDF

The buried arch structural system for underground structures

  • Hernandez-Montes, Enrique;Aschheim, Mark;Gil-Martin, Luisa Maria
    • Structural Engineering and Mechanics
    • /
    • v.20 no.1
    • /
    • pp.69-83
    • /
    • 2005
  • In many cases, underground structures are built using conventional above-grade structural systems to carry gravity load. This paper proposes the use of underground arches, termed "buried arches", to support gravity loads, wherein the horizontal thrust of the arch is equilibrated by soil pressure. Because the horizontal soil pressure increases with depth, the depth of the arch may be reduced as the depth below grade increases. Critical to the success of such an approach is a proper accounting of creep and shrinkage for arches made of reinforced concrete. This paper addresses the influence of equilibrium, creep, and shrinkage as they affect the design of the arch from a theoretical perspective. Several examples illustrate the use of buried arches for the design of underground parking structures.

An Analysis of External Waterproofing Materials and Construction Technology Status on Single Side Wall in Underground Structures (지하구조물 합벽구간 적용 외방수 재료 및 시공기술 현황 분석)

  • Kim, Meong-Ji;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.222-223
    • /
    • 2019
  • Waterproofing techniques used in underground structures do not reflect material and construction environments, but rely only on material properties, which inevitably lead to their limits in durable life. In particular, the government intends to investigate the current underground water treatment method and analyze the problems in order to prevent serious corrosion and aging of structures caused by underground water leaks and poor construction.

  • PDF

Geotechnical Approach in Design and Construction of Underground Structures A Systematic Parameter Estimation (지하 공간 설계와 시공의 지반공학적 접근과 실무적용 -지반계수의 합리적 추정)

  • Lee, In-Mo;Kim, Dong-Hyeon
    • Geotechnical Engineering
    • /
    • v.12 no.2
    • /
    • pp.43-58
    • /
    • 1996
  • In spite of drastic development of underground technology too many uncertainties still exist in design and construction of underground structures. Estimation of ground parameters might be one of those uncertainties in design of underground structures. It is not an easy task to estimate the parameters reasonably well in advance in the design stage. The main purpose of this paper is the best parameter estimation in the underground structures. In order to estimate unknown model parameters from the in-eitu measurements as well as prior estimates, the Extended Bayesian Method(EBM) is utilized and implemented with Finite Element Program. The parameter estimation model utilized in this study is applied to two underground structures : the one Pusan subway tunnel: and the other Darlington intake tunnel in Canada, and the effectiveness of the proposed model is illustrated.

  • PDF

A preliminary numerical analysis study on the seismic stability of a building and underground structure by using SSI (SSI를 이용한 건물과 인접지하구조물의 내진 안정성에 대한 기초 수치해석 연구)

  • You, Kwang-Ho;Kim, Young-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.23-38
    • /
    • 2018
  • Up to now, most of studies on seismic analysis have been limited to analyze buildings and underground structures individually so that the interaction between them could not be analyzed effectively. Thus, in this study, a dynamic analysis was conducted for soil-structure interaction with a complex underground facility composed of a building and an adjacent underground structure constructed on a surface soil and the bed rock ground conditions. Seismic stability was analyzed based on interstory drift ratio and bending stress of structure members. As a result, an underground structure has more effect on a high-rise building than a low-rise building. However the above structures were proved to be favorable for seismic stability. On the other hand, tensile bending stresses exceeded the allowable value at the underground part of the building and the adjacent underground structure so that it turned out that the underground part could be weaker than the above part. Therefore, it is inferred that above and underground structures should be analyzed simultaneously for better prediction of their interaction behavior during seismic analyses because there exist various structures around buildings in big cities.

Seismic Analysis of Underground RC Box considering Elastoplastic Interface Element (탄소성 경계면 요소를 고려한 지하 철근콘크리트 박스의 내진 해석)

  • 남상혁;송하원;변근주
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.109-116
    • /
    • 2002
  • Since experimental evaluation of underground RC structures considering interaction with surrounding soil medium is quite difficult to be simulated, the evaluation for the underground RC structures using an analytical method can be applied very usefully. For underground structures interacted with surrounding soils, it is important to consider path-dependent RC constitutive model, soil constitutive model, and interface model between structure and soil, simultaneously. In this paper, an elastoplastic interface model which consider thickness of interface is proposed and applied for the analysis considering the interaction. Failure mechanism of underground RC box of two story and two box subway station under seismic action is obtained and the effects of ductility of intermediate column to entire underground RC system are investigated through analysis.

  • PDF