• Title/Summary/Keyword: Underground Gas Pipelines

Search Result 71, Processing Time 0.022 seconds

Experimental Study on Rupturing of Artificial Flaw of Pipes for Life Prediction of Underground High Pressure Gas Pipes (지하매설 고압가스배관의 수명예측을 위한 인위결함 배관의 파열실험)

  • Lee, Kyung-eun;Kim, Jeong Hwan;Ha, Yu-jin;Kil, Seong-Hee;Jo, Young-do;Moon, Jong-Sam
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.62-71
    • /
    • 2018
  • According to own investigation conducted by Korea Gas Safety Corporation Gas Safety Research Institute in 2017, the length of underground pipes in domestic high-pressure gas pipelines is approximately 770km, of which 84% is buried in Ulsan and Yeosu industrial complexes. In particular, 56% of underground pipelines have been in operation for more than 20 years. This suggests urgent management of buried high pressure gas pipelines. PHMSA in US and EGIG in Europe, major causes of accidents in buried gas pipelines are reported as third party damage, external corrosion and loss of pipe wall thickness. Therefore, it is important to evaluate whether the defects affect the remaining life of the pipe when defects occur in the pipe. DNV and ASME have evaluated the residual strength of pipelines through the hydraulic rupture test using pipe specimens with artifact flaws. Once the operating pressure is known through the residual strength of the pipe, the wall thickness at the point at which the pipe ruptures is calculated. If we know the accurate rate of corrosion growth, we can predict the remaining life of pipe. In the study, we carried out experiments with A53 Grade.B and A106 Grade.B, which account for 80% of domestic buried pipes. In order to modify the existing model equation, specimens with a defect depth of 80% to 90% was tested, and a formula expressing the relationship between defect and residual strength was made.

The Influence on GAS pipelines Buried in nearby Tower of 345kV Transmission Line (345kV 송전선로 철탑이 인근에 매설된 가스배관에 미치는 영향)

  • Lee, H.G.;Ha, T.H.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.349-351
    • /
    • 2001
  • Because of the continuous growth of energy consumption and also the tendency to site power lines and pipelines along the same route, the close proximity of power lines and buried metallic pipelines has become more and more frequent. Therefore there has been and still is a growing concern about possible hazards resulting from the influence of power lines on metallic pipelines. When a ground fault occurs in an electrical installation the current flowing through the earthing electrode produces a potential rise of the electrode and of the neighbouring soil with regard to a remote earth. This paper analyzes the effects of ground faults when the current will flow into the soil from the foot of 345kV transmission line tower.

  • PDF

Health Monitoring System for the underground Gas Pipelines (지하 매설 배관 건전성 평가 시스템 개발)

  • Lee, ChangYeol;Jo, Young-Do;Park, GilJoo
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.224-226
    • /
    • 2015
  • 지하 매설 배관의 장기적 사용은 배관의 안전성과 건전성이 확보되어야 한다. 이를 위하여 진단, 평가, 보수에 대한 기술을 확보하고 지속적인 모니터링이 필요한 상태이다. 본 연구는 이러한 배관에 대한 건전성 평가를 활용하여 보수우선순위에 따라 배관을 관리할 수 있게 하는 기술을 개발하는 것이다. 이를 위하여 평가를 할 수 있는 모델에 대한 연구 그리고 모델을 실제 도시가스회사의 시스템과 연계하기 위한 기술 개발에 대한 연구가 진행되었다.

  • PDF

Risk Assessment Program of underground buried Pipeline Development (지하매설배관의 위험성평가 프로그램 개발)

  • Kim Tae Wook;Sung Jun Sik;Cho Yong Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.2 s.10
    • /
    • pp.37-45
    • /
    • 2000
  • The underground buried pipelines of Natural gas are relatively safer than any other pipelines of chemical plants, because Natural gas is non-corrosive fluid. But Natural gas is supplied normally the downtown area. So, it may be a disaster because of corrosion which is caused interference facilities, environment and third party accident which is caused facilities construction. Especially, it is very difficult to find out and inspect damages of pipeline because of buried pipelines. Therefore this paper approached to select and manage risk region pipelines according to introduction of underground buried pipeline's risk concept. Risk was indicated three parts - corrosion factor, design and construction factor, maintence and management factor - in this paper, Therefore qualitive risk of pipelines showed score as quantitative number. Also it was thought to be helpful in confidence and safety management that the concept of key index and failure supplementation measures to cost introduces this program. We developed this risk assessment program using visual basic tool and interfaced GIS.

  • PDF

A Fault Effect to Induced Voltage of Gas Pipeline in Transmission Systems (송전계통에서 고장에 따른 Gas Pipeline 유도전압 분석)

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1720-1725
    • /
    • 2008
  • Because of the continuous increasing of energy consumption, metallic pipelines are widely used to supply services to customers such as gas, oil, water, etc. Most common metallic pipelines are underground and are now frequently being installed in nearby electric power lines. In recent years, buried gas pipeline close to power lines can be subjected to hazardous induction effects, especially during single line to ground faults. because it can cause corrosion and it poses a threat to the safety of workers responsible for maintenance. Accordingly, it is necessary to take into consideration for analysis of induced voltage on gas pipelines in transmission lines. This paper analyzed the induced voltage on the gas pipelines due to the 154kV transmission lines in normal case and in different faulty case conditions using EMTP (Electro-Magnetic Transients Program).

Investigation for Earth Resistance and Leakage Current of D/L (배전선로 접지저항 및 누설전류 실태조사)

  • Lee, H.G.;Ha, T.H.;Bae, J.H.;Ha, Y.C.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.379-381
    • /
    • 2003
  • The sharing of common corridors by electric power transmission lines and pipelines is becoming more common place. However, such corridor sharing can result in undesired coupling of electromagnetic energy from the power lines to the near facilities. This causes induced voltages on underground metallic pipelines due to the power line currents. This could cause AC corrosion in the pipeline, which could in turn lead to disastrous accidents, such as gas explosion or oil leakage. This paper investigates for the limitation of induced voltage on the buried metal structures which is used in the inside and outside of the country. And then we measure the earth resistance and leakage current of 22.9kV distribution lines and pipe to soil potential of near pipelines in Seoul Korea. Hereby we can see the leakage current flowing through the earthing electrode have an effect on near pipelines.

  • PDF

An Evaluation of EOCS Regarding Safety Management Effects on Buried Gas Pipelines and Convenience of the Excavators and the Operators of Gas Companies

  • Ryon, Young-Don;Chae, Chung-Keun;Bang, Hyo-Jung;Yoon, Young-Kee;Lee, Su-Kyung
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.43-48
    • /
    • 2007
  • We introduced the Excavation One Call System (EOCS) as a pilot system, in Seoul, Korea. The system utilizes the phone and internet to transfer information about digging underground and buried gas pipelines, although currently written forms are used in accordance with the City Gas Business Law. After one year, we evaluated the business model by surveying the excavators and the operators of the gas companies. This paper shows that the EOCS was more effective in preventing the buried gas pipelines from being damaged than the existing method that has to use due form. It also shows that the EOCS was more convenient and cost efficient than the present policies in place. We come to the conclusion that the EOCS should be extended nationwide and gradually include other subsurface facilities.

Analysis of Stray Current Interference between Underground Pipelines and DC Electric Railways (매설배관과 직류전기철도의 표유전류 간섭분석)

  • Ha Y.C.;Bae J.H.;Ha T.H.;Lee H.G.;Kim D.E.
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.41-47
    • /
    • 2006
  • When an underground pipeline runs parallel with DC electric railways, it suffers from electrolytic corrosion caused by the stray current leaked from the railway negative returns, i.e., the rails. Perforation due to the electrolytic corrosion may bring about large-scale accidents even under cathodically protected condition. Traditionally, drainage bonding methods have been widely used as a mitigation method for stray current interference. In particular, the increased adoption of forced drainage method to gas pipelines makes the interference much more sophisticated. In this paper, we analyze the electric interference between pipelines and railways from the results of field investigation carried out in Seoul and Busan.

  • PDF

A Study on Development of Cathodic Protection on Underground Pipeline Measuring System (매설배관의 방식전위 측정시스템 개발에 관한 연구)

  • Kim, Jin-Jun;Seo, Min-Sung;Kim, Dong-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.66-71
    • /
    • 2014
  • Gas pipelines are the core facilities in the gas facilities and the most pipelines are buried underground and are exposed to the risk of corrosion caused by the soil characteristics and the environmental impact. The anti-corrosion potential and the corrosion status of the underground pipelines are measured periodically in accordance with the relevant laws and regulations. A study on the cathodic protection measurement system was carried out in order to solve the problems of the conventional measurement system. This paper describes the survey on the standards and the specifications of the cathodic protection measurement and the the reference electrode to meet the relevant regulations, and the development of the measuring circuit and the data transmission module to build the cathodic protection measurement system. This study verified the field applicability through the testing of the developed prototype and investigated on the problems of the previous studies and the future research and development direction.