• Title/Summary/Keyword: Underground Area

Search Result 1,151, Processing Time 0.024 seconds

Assessment of Sinkhole Occurrences Using Fuzzy Reasoning Techniques

  • Deb D.;Choi S.O.
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2004.10a
    • /
    • pp.171-180
    • /
    • 2004
  • Underground mining causes surface subsidence long after the mining operation had been ceased. Surface subsidence can be in the form of saucer-shaped depression or collapsed chimneys or sinkholes. Sinkhole formations are predominant over shallow-depth room and pillar mines having weak overburden strata. In this study, occurrences of sinkholes due to mining activity are assessed based on local geological conditions and mining parameters using fuzzy reasoning techniques. All input and output parameters are represented with linguistic hedges. Numerous fuzzy rules are developed to relate sinkhole occurrences with input parameters using fuzzy relational matrix. Based on the combined fuzzy rules, possibility of sinkhole occurrences can be ascertained once the geological and mining parameters of any area are known.

  • PDF

A Capacity of Refuge area in Multiple Occupancy Building with Underground Facility (지하연계복합건축물의 피난 안전구역 면적 산정)

  • Kim, Jong-Sung;Kim, Woon-Hyung;Lee, Yong-Jae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.272-276
    • /
    • 2011
  • 최근 발생한 부산 해운대 화재 이후 피난 활동이 제한적인 고층 건축물의 화재 안전에 대한 관심이 증대되고 있다. 그러나 현행 규정은 50층 이상의 초고층 건축물을 대상으로 하고 있으며 상대적으로 준 초고층 건축물에 대한 제도적 기반과 연구가 미비한 실정이다. 따라서 본 연구에서는 지하연계복합건축물에 관한 피난 안전구역면적 산정 기준에 대한 적용성을 분석하고자 국외의 관련 기준과 비교 분석하였다. 그 결과, 수용 인원에 관한 기준은 홍콩, 한국, 싱가포르, 중국 순으로 강화 적용하고 있으며 피난안전구역의 면적은 싱가포르의 경우 전체 수용 인원의 50% 이상과 1명당 $0.3m^2$을 전제로 하는 피난안전구역의 면적 기준이 국내의 각 층별 1/10의 면적의 합과 동일한 것으로 분석되었다.

  • PDF

A study on Design and Kinematics Analysis of Robot Hand Fingers (로봇핸드 핑거의 설계 및 운동학적 해석에 관한 연구)

  • Won, Jong-Bum;Ha, Eon-Tae;Kim, Byung-Chang;Cho, Sang-yeong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.18 no.4
    • /
    • pp.231-240
    • /
    • 2015
  • In this paper, it was presented to design and analyze the kinematics of grasping a rigid object by means of multi-degrees-of-freedom hand fingers. It is shown firstly that a set of kinematic equation describing dynamics system of the arm and object together with geometric constraint of tight area-contacts is formulated by Lagrange's equation. It has been presented secondly that the problems of controlling both the forces of pressing object and the rotation angle of the object under the geometric constraints are discussed. In this research, the control method for static stable grasping and enhancing dexterity in manipulating things is proposed. It is illustrated by computer simulation that the control system gives the performance improvement in the kinematic grasping of the hand fingers of robot.

Development of 154kV Gas Insulated Transformer (154kV급 가스절연 변압기 개발)

  • Woo J.H.;Choi Y.L.;Kim K.M.;Lee J.Y.;Seok B.Y.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.532-539
    • /
    • 2005
  • The demand of Gas Insulated Transformer(GIT) using $SF_6$ gas as insulating and cooling medium is being increased dramatically in the underground substation of urban area because it has the advantages of non-flammable and non-explosive, etc. This paper describes the structural features and advantages of the gas insulated transformer compare to an oil immersed transformer, and presents a brief overview of the consideration and technology which apply to $SF_6$ gas insulated transformer.

Mechanical Properties and Durability of Abrasion of EVA Concrete Reinforced Steel Fiber (강섬유 보강 EVA 콘크리트의 역학적 특성 및 내마모성)

  • Sung, Chan Yong;Nam, Ki Sung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.5
    • /
    • pp.45-54
    • /
    • 2014
  • This study was performed to evaluate compressive strength, flexural strength, static modulus of elasticity, stress-strain ratio and durability of abrasion on EVA concrete reinforced steel fiber (SF) in order to use hydraulic structures, underground utilities, offshore structures and structures being applied soil contaminated area. It is used ordinary portland cement, crushed coarse aggregate, nature fine aggregate, EVA redispersible polymer powder, superplasticizer and deforming agent to find optimum mix design of EVA concrete reinforced steel fiber. EVA concrete reinforced SF was effected on the improvement of mechanical properties and durability of abrasion.

Quantitative Determination of Salidroside and Tyrosol from the Underground Part of Rhodiola rosea by High Performance Liquid Chromatography

  • Linh, Pham-Tuan;Kim, Young-Ho;Hong, Seon-Pyo;Jian, Jiang-Ji;Kang, Jong-Seong
    • Archives of Pharmacal Research
    • /
    • v.23 no.4
    • /
    • pp.349-352
    • /
    • 2000
  • A reversed-phase high performance liquid chromatographic method was developed to determine salidroside and tyrosol simultaneously in the Rhodiola rosea. The optimum condition was Nova-pak $C_18$as stationary phase, 6.5% methanol in water as mobile phase and detection at UV 225 nm. The identification was carried out by comparing the retention time and LC/MS spectrum of the relevant peaks with those of isolated standards. The contents of salidroside and tyrosol in the samples gathered from various area in China were ranged over 1.3-11.1 ${m}g/g$ and 0.3-2.2 ${m}g/g$, respectively.

  • PDF

Deformation Characteristics of Cut-Slope Composed of Colluvial Soil in Tae Baek Area (강원도 태백지역의 붕적층 절토사면의 변형특성)

  • 김경열;이대수;홍성연
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.467-474
    • /
    • 2002
  • Colluvial sell has a very unique deformation property, particularly when it is subject to the cutting work entailed in a variety of construction. In this study, the cut slope tying on a colluvial layer in which the transmission tower had been installed were investigated to find out the cause of deformation. In-situ tests such as boring, surface-wave analysis (MASW) were employed to look into the physical composition of underground layers and FEM including LEM were carried out to simulate the construction steps. The result shows that the stress relaxation followed by road construction induced the deformation of the slope and damage in the foundation of the transmission tower.

  • PDF

Numerical Analysis on Features of Airflow through Open Door in Pressure Differential System (급기가압 제연시스템의 방연풍속 형성특성에 대한 수치해석적 분석)

  • Kim, Jung-Yup;Rie, Dong-Ho;Kim, Ha-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.463-468
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. In pressure differential systems for smoke management, the speed of airflow through open door between accommodation and lobby should be maintained over 0.5m/s on the whole area of door to prevent smoke from infiltrate into evacuation root when the door is open for refuge. The numerical analysis on features of airflow through open door are carried out and the results are presented.

  • PDF

Transient Analysis and Evaluation of 345kV Combined Transmission Line Connected with GIL (345kV급 GIL이 연계된 혼합송전선로의 뇌서지해석 및 평가)

  • Jang, Hwa-Youn;Lee, Jong-Beom;Kim, Yong-Kap;Jung, Chae-Kyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1949-1955
    • /
    • 2010
  • This paper describes the characteristic and effectiveness of combined GIL transmission line through lightning surge analysis. In addition the XLPE cable is analyzed in the same condition to compare with GIL. Lighting surge analysis is carried out by EMTP/ATP-Draw to obtain overvoltage of GIL and XLPE cable at service-point and load-out area of underground line. Propagation velocity is calculated in combined transmission lines with GIL and XLPE cable. The overvoltage is also analyzed on GIL and XLPE cable with or without arrester operation. The Analysis results show that overvoltage of GIL is occurred higher than XLPE cable at the same condition. Therefore it is evaluated that the application of GIL at the field should be considered cautiously when more detailed transient analysis, another electrical testes and economic evaluations are implemented.

Analysis of the Stray Current Conditions in Subway DC Electrification System (I) Seoul Metropolitan Area (지하철 직류 급전시스템의 표유전류 실태 분석(I) 서울 지역)

  • Ha Yoon-Cheol;Ha Tae-Hyun;Bae Jeong-Hyo;Kim Dae-Kyeong;Lee Hyun-Goo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1364-1366
    • /
    • 2004
  • When an underground pipeline runs parallel with DC-powered railways, it suffers from electrolytic corrosion caused by the stray current leaked from the railway negative returns. Perforation due to the electrolytic corrosion may bring about large-scale accidents even cathodically protected systems. Traditionally, bonding methods such as direct drainage, polarized drainage and forced drainage have been used in order to mitigate the damage on pipelines. In particular, the forced drainage method is widely adopted in Seoul. In this paper, we report the analysis of the stray current conditions in Seoul subway DC electrification system.

  • PDF