Proceedings of the KIEE Conference (대한전기학회:학술대회논문집)
- summer
- /
- Pages.1364-1366
- /
- 2004
Analysis of the Stray Current Conditions in Subway DC Electrification System (I) Seoul Metropolitan Area
지하철 직류 급전시스템의 표유전류 실태 분석(I) 서울 지역
- Ha Yoon-Cheol (Korea Electrotechnology Research Institute) ;
- Ha Tae-Hyun (Korea Electrotechnology Research Institute) ;
- Bae Jeong-Hyo (Korea Electrotechnology Research Institute) ;
- Kim Dae-Kyeong (Korea Electrotechnology Research Institute) ;
- Lee Hyun-Goo (Korea Electrotechnology Research Institute)
- Published : 2004.07.14
Abstract
When an underground pipeline runs parallel with DC-powered railways, it suffers from electrolytic corrosion caused by the stray current leaked from the railway negative returns. Perforation due to the electrolytic corrosion may bring about large-scale accidents even cathodically protected systems. Traditionally, bonding methods such as direct drainage, polarized drainage and forced drainage have been used in order to mitigate the damage on pipelines. In particular, the forced drainage method is widely adopted in Seoul. In this paper, we report the analysis of the stray current conditions in Seoul subway DC electrification system.
Keywords