• 제목/요약/키워드: Underground Area

검색결과 1,151건 처리시간 0.024초

집적암거에 의한 대류수개발에 관한 연구 (A study on the Development of Ground water by the Infiltration Gallery)

  • 한욱동
    • 한국농공학회지
    • /
    • 제15권3호
    • /
    • pp.3096-3106
    • /
    • 1973
  • As a link in the chain of antidrought measure, our attempt is made to obtain basic informations on the construction of an infiltration gallary which can be supplied with irrigation water by catching of underground water in small river beds, which is economical, permanent and efficient. The experiment was made, concerning the structure of catchment conduits, by constructing a model sand tank $1.5m{\times}5m{\times}1.5m$ in dimension made of reinforced concrete. Various kinds of measuring equipment were attached to the model tank which contains a set of catchment conduits, each of them was made 30cm in diameter and 60cm in length with the ratio of sectional area to total area of influx holes 10:1, 20:1, 30:1. The average size of influx holes was fixed from 0mm to 10mm, 20mm and 30mm in diameter respectively. Obtained results are as follow; (a) In view of the water catchment capacity, manufacturing cost and the antipressure strength of the catchment conduits, it is the best method to decide the total number of influx holes 20 per sq. meter of each tile surface, and the size of influx holes 20mm in diameter, when the conduits have diameter less than 1m. (b) The greatest factor of safety against external load is to arrange the influx holes in a zigzag manner on the tile surface. The most effective formula of arrangement is $S{\geqq}\sqrt{2gd}$ where: s : spacing of opening row. g : spacing of opening line. d : diameter of influs hole.

  • PDF

피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구 (A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester)

  • 정기석;길형준
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

도시내 소규모 단지의 상.하수도 시설물관리를 위한 GIS 기술의 활용 (The Management of Water Supply and Sewerage Facilities using GIS Technique for Urban Local Area)

  • 김충평;김감리
    • 한국측량학회지
    • /
    • 제17권1호
    • /
    • pp.51-59
    • /
    • 1999
  • 도시 기반 시설중 하나인 상하수도는 도시 규모의 확대와 인구의 증가, 그리고 시설의 노후화로 인한 기존 관리 방법에 많은 한계가 나타나고 있는 실정이다 또한 최근에는 하수에 의한 지하수의 오염과 수도관 파손 등에 의한 사고시 신속한 대응능력의 부족으로 행정적인 문제가 빈번히 발생하고 있는 현실이 GIS에 의한 시설물관리의 필요성이 절실히 요구되고 있다. 따라서 본 연구에서는 이러한 문제점을 감안하여 시설물관리 방법으로 GIS기법을 이용하여 체계적이고 합리적인 시설물 유지관리가 가능할 수 있는 계기를 마련하고자 한다. 끝으로 상하수도 시설물관리에 GIS기법을 활용하므로써 합리적이고 체계적인 시설물관리가 가능함을 제시하고 시설물관리의 응용방안을 제시하여 실무자의 업무 효율을 극대화하므로써 본 연구의 목적을 달성하고자 한다.

  • PDF

도시 주요조경수종의 연간 $CO_2$흡수 (Annual $CO_2$ Uptake by Urban Popular Landscape Tree Species)

  • 조현길;조동하
    • 한국조경학회지
    • /
    • 제26권2호
    • /
    • pp.38-53
    • /
    • 1998
  • This study quantified annual net carbon uptake by urban landscape trees and provided equations to estimate it for Ginkgo biloba, platanus occidentalis, Zelkova serrata and Acer palmatum, based on measurement of exchange rate for two years growing seasons from Sep., 1995 to Aug., 1997. The carbon uptake was significantly influenced by photosynthetic capacity, photon flux density and pruning. Ginkgo biloba showed the highest rate of net CO\sub 2\ uptake per unit leaf area and Acer palmatum did the lowest rate among those species. A tree shaded by adjacent building over the growing seasons showed net CO\sub2\ uptake per unit leaf area much lower than another tree of the same species less shaded. Annual net carbon uptake per tree was 19kg for Zelkova serrata, but only 1 kg for Ginkgo biloba and Platanus occidentalis with crown volume dwarfed from pruning. One Zekoval serrata tree annually offset carbon emission from consumption of about 32 liter of gasoline or 83 kWh of electricity. Strategies to improve CO\sub 2\ uptake by urban landscape trees include planting of species with high potosynthetic capacity, sunlight-guaranteed road and building layout for street trees, planting of shade-tolerant species in the north of buildings, and relocation of utility lines to underground and minimized pruning.

  • PDF

반무한 다중 구조계의 비선형 유한요소 - 경계요소 해석 (Analysis of Multi-Layered Structural Systems Using Nonlinear Finite Elements-Boundary Elements)

  • 김문겸;장정범;이상도;황학주
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 봄 학술발표회 논문집
    • /
    • pp.58-64
    • /
    • 1992
  • It is usual that underground structures are constructed within multi-layered medium. In this paper, an efficient numerical model ling of multi-layered structural systems is studied using coupled analysis of finite elements and boundary elements. The finite elements are applied to the area in which the material nonlinearity is dominated, and the boundary elements are applied to the far field area where the nonlinearity is relatively weak. In the boundary element model 1 ins of the multi-layered medium, fundamental solutions are restricted. Thus, methods which can utilize existing Kelvin and Melan solution are sought for the interior multi-layered domain problem and semi infinite domain problem. Interior domain problem which has piecewise homogeneous layers is analyzed using boundary elements with Kelvin solution; by discretizing each homogeneous subregion and applying compatibility and equilibrium conditions between interfaces. Semi-infinite domain problem is analyzed using boundary elements with Melan solution, by superposing unit stiffness matrices which are obtained for each layer by enemy method. Each methodology is verified by comparing its results which the results from the finite element analysis and it is concluded that coupled analysis using boundary elements and finite elements can be reasonable and efficient if the superposition technique is applied for the multi-layered semi-infinite domain problems.

  • PDF

터널굴착이 지상구조물에 미치는 영향평가 및 발파지침설계 (Ground Vibration in Tunnelling by Blasting and its Effect on Surface Structures)

  • 신희순;한공창;류창하;신중호;박연준;최영학
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.463-470
    • /
    • 2000
  • In tunnel excavation by blast beneath the surface structures in urban area, the characteristics of ground vibration induced by blast and its influence on surface structures are analyzed by the field test and the numerical analysis on dynamic behaviors of the structure. According to the field test on the propagating characteristics of blast vibration through the rock mass and the concrete foundation pile. the attenuation index of peak particle velocity with distance shows the range of 1.7∼2.0 for the rock mass and the range of 2.0∼2.3 for the concrete pile. This shows that the blast vibration reduces more rapidly in the concrete pile. It is known from the numerical analysis on dynamic behavior of the structure that the coefficient of response, velocity ratio of structure response to input wave, is different according to the story of the structure. It can be said from this research that the characteristics of the ground vibration and the dynamic behavior of the structure should be well evaluated and be considered as important factors for safe blasting design especially in underground excavation at shallow depth in urban area.

  • PDF

최신 투 아치 터널의 굴착 공법과 구조 및 설계 (New Construction and Design Method of Two Arch Tunnel)

  • 윤석렬;권오현;서동현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.938-945
    • /
    • 2004
  • In order to cope with ever growing traffic flow and complexity in the urban area, construction demands for expanding and realigning of existing urban roads and massive development of underground space within the urban area are in its increasing trend, it is fact that, mainly due to lack of statistical data accumulation through real construction, technology and construction practice to support such demands can hardly be said to have been established enough and leave many things still to be developed. These circumstances therefore came to motivate me to get into a study for a particular subject of "Design Basics for Closely Neighbored Twin Tunnel" among others, and also to put forward subjects required to be further studied in this connection in the future as follows: 1) To make a new economical design model for closely neighbored twin tunnel not only to make a drain for center perfect but also a tunnel construction safe. 2) Further efforts should be exerted for establishment of general standards for design and construction of various types of large cross-section tunnels including Twin structure.

  • PDF

암과 흙 경계면에서의 전단강도를 이용한 산사태 특성 연구 (A study on landslide charateristics by using the shear strength of the interface of rock and soil)

  • 이수곤;선건규;이천용;김재헌;이창노
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.606-613
    • /
    • 2004
  • One of the major forces that causes landslide is the amount of underground water resulted from rainfall and shear strength. As a result of close study on the landslide area affected by typoon Rusa it is observed that many landslides took place at the interface of rock and soil. Based on this observation that shear strength at the interface played a great role in landslide of the hilly area, two shear strengths were measured on different places, one at the interface between rocks and soil and the other just on soil. The two values thus derived were compared and used to review the safety factor for the hilly areas already collapsed. Back analysis was also used to calculate the ground water table according to the different rock types at the time when degradation happened.

  • PDF

제주시 해안경관을 고려한 해수인수관 관리방안 (Management of Water Pumping System in Coastal Area of Jeju City Based on Coastal Landscape)

  • 조은일;이병걸
    • 한국환경과학회지
    • /
    • 제15권9호
    • /
    • pp.871-880
    • /
    • 2006
  • Water management treatment of coastal region has been an important problem in Jeju city since the distributions of pipeline of the pumping system made a bad view in coastal region. To solve the problem, we observed the pipelines that are on the surface around the coastal region from Tapdong to Doduhang. From the observations, we found that Todong and Dodu areas were not unsightliness because the all pipelines were located in underground. However, the other areas, such area Yongdam, Handugi, Yongdam fishing village, had a serious problem for the coastal landscape view. To solve the problem, at we estimated coastal land color characteristics of Jeju city based on the observation of the pipelines. The estimated color panel shows that the green, blue and grey colors are a dominant factors of the Jeju coastal region. Based on the color panel, we proposed two methods, that is, one is a short time treatment, the other is a long time one. The short is based on the colour treatment, which is pipeline colour changing into surround natural one. The long time is the construction plan design method. Although the later method was very useful in Jeju island. However, it takes a lot of time and money. Therefore, in the situation, the short time is the better than the long time one.

경부선 직하부를 나란히 통과하는 도심지 터널에 있어서 지표물리탐사 및 암반등급 평가 사례 연구 (The geophysical survey and rock classification suitable for the design of a tunnel in urban area passing underneath the Gyeongbu Line(Railload))

  • 이건;김은덕;사상호;차영호;김태영;정두석;황낙연
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.673-679
    • /
    • 2005
  • Urban conditions such as underground facilities and ambient noises due to cultural activity restrict the application of conventional geophysical techniques in general. We used the linear array microtremor technique which uses these noises as strong energy source. The result parameter of the survey is shear wave velocity profile which had been applied as an fundamental information for the determination of the rock support type in tunnel design. This study was the first case in Korea which utilized a surface geophysical technique yielding successful result in urban area especially under the existing rail ways. The quantitative relation between the shear wave velocity from this method and the rock mass rating(RMR) determined from the inspection of the cores recovered from the same boreholes showed high statistical relationship. These correlations were then used to relate the shear-wave velocity to RMR along the entire profile.

  • PDF