• Title/Summary/Keyword: Underground Area

Search Result 1,145, Processing Time 0.024 seconds

Land Development Project Area Underground Facility Management A Plan Using GIS (GIS를 활용한 택지개발사업지구 지하시설물 관리방안)

  • 김감래;이재기;임건혁
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.329-334
    • /
    • 2003
  • The aim of this study is propriety review for underground facility surveying on development area of land for housing and efficient management. Because of integration information administration system construction of the nation and development of information technology, construction of Urban information system(UIS) to manage systematically city space is increasingly necessary We manage systematically attribute information for each lot in the development area of land lot housing that it Is connected with NGIS in order to drive gradual computerization of underground facilities and arrange the base of facility management. Review arrangement methods on development area of land for housing makes it to check safety accident of urban and to leading base of urban information. Thus, this study draw the most suitable way through analysis of driving methods and expectation effect from above facts.

  • PDF

Computer Simulation for Working Condition of Undergroundwork Using TOP DOWN Technique (TOP DOWN 지하공사의 작업환경체크 컴퓨터시물레이션에 관한 기초적 연구)

  • 고성석;손기상;심경수
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.96-105
    • /
    • 1995
  • The better industry develops, the more spaces need but in the limited area. Most building become larger and more complicated if the more spaces need in the constant area. And this leads to do underground work in long period generally six(6) months for 6 basement stories due to the selection of TOP DOWN technique. Working environment in this underground area can be problems and should not be overlooked, because air quality in underground spaces become quickly worse. Recently, department name to control construction safety has been changed to ENVIRONMENT & SAFETY TEAM from SAFETY TEAM. This means that it is very important to control against environmental condition at site so much. Overall construction work as well as underground work should conform to the requirement of working environment, particularly against inhabitants around the construction area. Strut protection, one of earth protection method, in case to 40m long strut may become weaker due to thermal stress or its longitudinally compressive strain and the another one, earth anchor protection may not be applied to the site In case of encroaching on vertical underground borderline because of regulation to prohibit it. It is necessary that TOP DOWN technique should be introduced in order to solve the external and internal problem of the site such as difficulty level of the work, potential danger with excavating depth, and shortening workperiod. It is needed that improving way of working condition should be shown and simplified computer simulation program should be also provided for checking pollution level & ventilation, excluding of lighting problem here. Results measured with conformance to the Regulation for Working Environment Measurement, enforced by Ministry of Labor have been applied to the computer program developed here. Sample air taken at unit workplace which was considered as exposing condition of pollutant at breathing point and within a range of behavior of the workers, Identified exposing group in underground work, using Moded Flow Life Finally, three types of ventilation system, type I with blower & ventilator, type II natural supply with mechanical ventilation system, and type I mechanical ventilation with Drivent Fan Unit System are selected for this study.

  • PDF

Optimization of the Layout of a Radioactive Waste Repository Based on Thermal Analysis (열해석에 기초한 방사성폐기물 처분장 배치 최적화)

  • Kwon Sangki;Choi Jong-Won;Cho Won-Jin
    • Tunnel and Underground Space
    • /
    • v.14 no.6 s.53
    • /
    • pp.429-439
    • /
    • 2004
  • The deep underground High Level Waste (HLW) repository to dispose of 36,000tons of spent fuel from the reactors in Korea needs about $4km^2$ repository area. In this study, the deep undergrond repository layout was optimized to minimize the excavation rock volume as well as underground repository area. In the optimization, the results from thermal analysis were used to define the influence of tunnel and deposition hole spacings on repository layout. The repository area and excavation rock volume could be reduced with longer disposal tunnel length. When it is necessary to reduce the repository area with satisfying thermal criteria, it is better to reduce tunnel spacing and increase deposition hole spacing. In contrast, the excavation rock volume can be reduced by increasing the tunnel spacing and decreasing the hole spacing.

A Study on Indoor Radon Concentrations in Urban Area (도시 일부지역에서의 실내 라돈농도에 관한 연구)

  • 김순애;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.89-98
    • /
    • 2002
  • This study was taken in general hospital, hotel, shopping center, underground cafe, school, house, for the purpose of investigating the distribution of indoor radon concentration in urban area, by E-PERM which approved U.S. EPA, between August and November 1999. There are two sampling Places were exceed 148 ㏃/㎥(4 pCi/L; U.S EPA remedial level), difference mean is 24.0㏃/㎥ when compared with underground vs. aboveground indoor radon concentration in the same building and ratio is 1.6, so underground area is higher than aboveground (p<0.05). Influencing factors were examined. They related to the location of sampler(detector) open or near the door is lower radon concentration than inside portion, which explains probably open area has better ventilated air and dilutes indoor radon concentration. Temperature has a negative relationship (p<0.05) with indoor radon concentration and relative humidity has a positive (p<0.05) Simultaneously to investigate water radon concentration, collected piped-water and the results were very low, which is the same in piped-water concentration other countries. In conclusion, underground indoor radon concentration is higher than aboveground. Concentration was related to sampling spot, open portion is lower than inside. Higher the temperature, lower the indoor radon concentrations. On the other hand higher the relative humidity, higher the indoor radon concentrations. Indoor radon concentration is influenced by sampling point, temperature, relative humidity.

A Study on the Design Structural Concepts and the Elemental Characteristics for the Utilization of Underground Space (지하공간 활용을 위한 디자인 구성개념 및 요소특성에 관한 연구)

  • 이영수;김민경
    • Korean Institute of Interior Design Journal
    • /
    • no.29
    • /
    • pp.94-102
    • /
    • 2001
  • The urban land is incapacitated to grow and correspond to demand the space in urban area. And recently, rapid increasing of population and complex of urban function on pushed to develop the underground space. In Korea, the underground space development in inefficient in aspect. because development of underground space have not consistent and systematic planning method in underground environment inclounding interion design, extererior design. Therefore this study is suggested the design element for comfortable underground living environment and assortment on utilization of underground space. The results of this study on utilization are security of space through land use efficiency, conservation of historical place, building and natural environment, and technological characteristics, mental image. Accordingly, this study is proposed design element that make comfortable underground space as aspect from stimulation and diversity, sapciousness and feeling of warmth and dryness to compensate improper image of underground space, spacial orientation and way finding.

  • PDF

A Case Study on Reinforcement of Ground and Foundation against Subsidence in Abandoned Mining Area (폐광지역 침하방지를 위한 지반 및 구조물기초 보강)

  • Kim, Do-Hyung;Choi, Chang-Rim;Kim, Dong-Hyun;Lee, Du-Hwa;Lee, Baek-Song;Je, Hae-Chan
    • Tunnel and Underground Space
    • /
    • v.17 no.4
    • /
    • pp.255-265
    • /
    • 2007
  • As the mechanism and effect range of subsidence are altered according to the various conditions (the ground condition, the earth pressure, the geometric condition of underground cavity and the structure load), the analysis and prediction of subsidence in abandoned mining area are very difficult. Also, as the geological characteristics and the mining methods are differed in each mines, the application of the pre-existing reinforcements without improvement has a lot of difficulties and limits. In this study, the various underground investigation such as long-depth core drilling, seismic tomography and BIPS (borehole image processing system) were performed, the distribution of underground cavity and coal seam and rock relaxation condition were analyzed. And we predicted the type of subsidence and estimated the subsidence by theories of mining subsidence. With these results, we analyzed the mechanism of subsidence occurrence in the research object area. Finally, we improved existing methods which were applied to the abandoned mining area and also we established the rational reinforcement for the ground and structure foundation against each subsidence cause.

Design and Implementation of Visual Filtering for Integrated Underground Map Security (보안을 고려한 지하공간통합지도의 가시화 필터링 설계)

  • Kim, Yong Tae;Park, Chan Seob
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.477-482
    • /
    • 2021
  • The integrated underground space map system provides information on infrastructure that requires security, but to prevent rupture accidents during excavation work at the underground construction site, it must provide information on all underground facilities on the site. Providing additional information other than the object of interest to the user is a factor that increases the risk of information leakage of security data. In this paper, we design the visualization filtering method that when visualizing the integrated underground space map in the field, the visualization of entire underground facilities of interest to workers is performed, but visualization of other underground facilities is minimized to minimize the risk of security data information leakage. To this end, a visualization area of a certain distance for each of the underground facilities of interest was created, and an integrated visualization filter was created with spatial union operation. When the integrated underground map is output on the screen, only the objects located within the filter area are visualized using the generated filter information, and objects that exist outside are not visualized, thereby minimizing the provision of information to the user.

Characteristics of Planting Design according to Parking Lots Type in Multi-family Housing Complex (공동주택단지의 주차장 유형에 따른 식재특성)

  • Hong, Seong-Rae;Jeong, Dae-Young;Shim, Sang-Ryul
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • The number of registered vehicles increased to one million in 1985 and ten million in 1997, and the parking lots in multi-family housing complex that had been mainly constructed on the ground level began to be constructed in underground levels. Therefore, planting design in such complex were greatly changed. This study classifies the parking lots in multi-family housing complexes located in Cheongju into three categories: above-ground, mixture of above-ground and underground, and underground. The characteristics of planting design in each were then analyzed. The rate of parking per family increased by two or more in the type of mixture when compared to in the type of above-ground. As underground parking lots became dominant, the rate of parking per family increased to one car or more. The green area ratio did not change considerably when above-ground parking was combined with underground parking, but the green area per total floor space was reduced, which indicates the quality of green area became lower. Most of the parking lots in multi-family housing complexes since 2000 have been constructed underground, and the green area became larger. As for the species of trees used in planting design, trees that are vulnerable to damage by blight and harmful insects and may be repugnant have been reduced and replaced by trees whose shapes are beautiful and whose flowers and fruits can be appreciated, such as Chionanthus retusa, Malus floribunda, Styrax japonicus, Prunus mume, Lagerstroemia indica. Pine trees are variously planted with diversified standards, and, in particular, tall pine trees are being utilized as focal points. Herbaceous flowers began to be planted in underground parking lots constructed since 2000, and they are expected to be planted even more due to the appreciation of their flowers and their splendid appearance.

공주 능치지역 천부 지하구조에 대한 지구물리학적 연구

  • Kim, Gi-Hyeon;Seo, Man-Cheol
    • Journal of the Korean Geophysical Society
    • /
    • v.4 no.2
    • /
    • pp.103-111
    • /
    • 2001
  • Geophysical survey was carried out to derive some information on the existence of near-surface anomalous body at Reung-Chi area in Kongju. Resistivity, seismic, magnetic and gravity method were applied. Geophysical survey that was applied was the electrical resistivity survey, seismic survey, magnetic survey, gravity survey. These surveys are analyzed to provide data of high resolution. As a result of analysis of resistivity survey, anomalies showing high resistivity anomaly than around appeared, and the one showing M-shape out of those explains the possibility that underground common or other underground structure or geographical anomalous zone could exist in the underground. As a result of analysis of seismic survey, it is clear that the low velocity layer is spread as far as the bottom of the underground. It is possible to presume that it is a phenomenon appearing while going through the underground space where it is lying in the underground. Area that shows unusual situation in interpretation of data on seismic waves are included into the area that once showed resistivity anomaly, the results of both seismic surveys come in accord. As a result of magnetic survey, a circle-shape of twin magnetic fields in the area where abnormalities are shown between electrical resistivity survey and seismic survey is appeared. Given the area of gravity survey, abnormalities whose density is different from the one around the bottom of the underground. As a result of analogizing the data of underground of the subsurface based on analysis of data from each survey, it was interpreted that anomalous zone exists commonly in the research areas.

  • PDF

A Study of Standardization for Establishing Integrated Infrastructure of Underground Space Information and its Availability (지하공간정보 통합 인프라 구축을 위한 표준화방안 및 활용성에 관한 연구)

  • Seok, Cheol Ho;Kang, Yu Ra;Jang, Yong Gu;Kang, In Joon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.4
    • /
    • pp.105-115
    • /
    • 2012
  • Today, the domestic construction area has changed from the ground development area to the underground space development area. In addition, the problems of sprawling development and environmental pollution in the process of developing underground space have become significant. In the circumstances, it is expected that the use of underground space information, which helps to understand underground space, will be on the sharp rise. However, the underground information in Korea is separately established and managed by each institution, and it is difficult to use the information in an integrated way. Therefore, at the time when the information on underground space is integrated, it is required to perform the integrated DB standardization in order to establish the integrated infrastructure of underground space information. In this work, this researcher studied a plan of using the standardization of the integrated infrastructure of underground space information. As a result, this work suggested standardization of each geologic stratum, standardization of unit systems, and standardization of the connection of underground space information regarding the standardization contents of underground space information integration. To examine its availability, this researcher conducted a questionnaire survey with experts of each institution. As a result, the suggested plan was found to be have high availability.