• Title/Summary/Keyword: Under-test

Search Result 14,560, Processing Time 0.038 seconds

Performance improvement of SOC indicator for electric vehicle using hydrometer (온-라인 비중계를 이용한 전기자동차용 바테리 잔존용량계의 성능개선)

  • 박종건;임영철;박철수;류영재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.423-426
    • /
    • 1996
  • The conditions to be satisfied with SOC(State-of-Charge) indicator installed on the electric vehicle were that it should be used under frequent loading conditions and that it should enable the monitor to adjust to the aging effect. But, the state-of-charge test requires a lengthy stabilization period after discharge cycles and the ampere-hour test requires the knowledge of the battery capacity in terms of amp-hours. However, a monitoring technique combining the state-of-charge test to enable the monitor to adjust to the aging effect with the ampere-hour test to use under frequent loading condition is studied and implemented on a microcontroller-based circuit in this paper. Specially, optical fiber is used to realize hydrometer which is immune to electromagnetic interference and toxic environment and makes it possible to be used in a wide temperature range.

  • PDF

A Study on the Performance Evaluation of Moisture Transfer in Clothing under Wearing Conditions -Evaluation by Covaltous Chloride Method- (의복 착용시 의복의 수분전달성능 평가에 대한 연구 -염화 코발트 법을 이용한 평가-)

  • 홍경희
    • Journal of the Korean Home Economics Association
    • /
    • v.27 no.4
    • /
    • pp.41-50
    • /
    • 1989
  • Cobaltous Chloride method has been known as a sufficiently good test methodolgy for the dynamic moisture transfer through textile fabrics. In the current study, Cobaltous Chloride method was adopted and modified to test dynamic moisture transfer in clothing under actual wearing conditions. It was possible to test the significant difference between fabric types by controlling the position of CoCl2 impregnated swatch (LD type), time scale of the moisture transfer (within 10 mins), experimental design (split plot desing) and other miscellaneous experimental techniques. As results, it was concluded that Cobaltous Chloried method is a satisfactory screening test to predict moisture related comfort properties of clothing as won.

  • PDF

The Deformation-Strength Characteristic for Gravel Material(1) - Development for Large Triaxial Test Device - (조립재료의 변형-강도특성에 대하여(I) - 대형삼축시험장치의 개발 -)

  • 신동훈;오병현;박한규;박성진;황성춘
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.311-318
    • /
    • 2000
  • In constructions of dams and ports structure, gravels are used as principle structural materials. Gravels have different material property compared with other materials like soil and concretes, etc. For example, material properties of gravels obtained from normal triaxial compression test are usually overestimated due to scale and penetration effects. Also, material properties of gravels under dynamic loads are the main interest when structural behavior of rockfill dam under earthquake loads is analyzed. The development of large triaxial compression apparatus is needed for the better estimation of material property of gravel. This paper reports work in progress to development of large triaxial compression apparatus.

  • PDF

Field Test of High-Speed Transponder System for Rail Transport (철도교통용 고속 트랜스폰더시스템 실차 시험)

  • Park, Sungsoo;Kim, Seong Jin;Lee, Jae-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.208-213
    • /
    • 2016
  • In order to detect the exact position of high-speed train, it is necessary to obtain location information from the transponder tag installed along the track. When the transponder tag receives the energizing signal from the train, it sends a telegram to the reader, which includes location information. In high-speed railway environment, this telegram can be corrupted by electromagnetic interference caused by onboard electric train power equipments or wayside devices. In order to assess the performance of transponder system under this harsh environment, we carried out field test using HEMU-430X. Field test results are briefly introduced and discussed for the evaluation of the transponder system under development.

Durability of Fiber Reinforced Composites under Salt Water Environments (염수환경을 고려한 섬유강화 복합재의 내구성 평가)

  • Yoon Sung-Ho;Hwang Young-Eun
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.391-396
    • /
    • 2005
  • Salt water spray test and salt water immersion test were experimentally conducted in order to investigate the durability of fiber reinforced composites under salt water environment. The specimens were made of glass fabric reinforcement and phenolic resin. Mechanical test was performed to obtain mechanical properties such as tensile properties, flexural properties, and shear properties by varying with exposure times. Also dynamic mechanical test and FTIR were conducted to investigate a change in chemical structure as well as thermal analysis properties such as storage shear modulus, loss shear moduls, and tan ${\delta}$. According to the results, salt water environment has effected on mechanical properties and thermal analysis properties and especially the durability of glass fabric/phenolic composites were severely affected on salt water immersion environment rather than salt water spray environment.

  • PDF

Traffic Generator for Performance Test of the TDX-10 Packet Handler (TDX-10 패킷처리기의 성능척정을 위한 트래픽발생기의 설계)

  • 정중수;전경표
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.3
    • /
    • pp.411-417
    • /
    • 1995
  • Packet switching is an important aspect of ISDN. In the TDX-10 switching system, which is being developed as an ISDN exchange in Korea, the packet switching function is implemented on the basis of Case B scenario of X.31. After implementing the packet switching function the performance test must be executed to check whether the design objectives of performance are satisfied or not. However, it is not easy to set up test environment for performance measurement under full load conditions. This paper presents the design of the traffic generator which enables us to do performance test of the TDX-10 packet handler under full load conditions. To generate packet traffic we change only software programs without any change of the hardware system of the packet handler.

  • PDF

A Method to Generate Test Patterns for Scan Designed Logic Circuits under Logic Value Constraints (논리값 제약을 갖는 스캔 설계 회로에서의 자동 시험 패턴 생성)

  • Eun Sei Park
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.2
    • /
    • pp.94-103
    • /
    • 1994
  • In testing for practical scan disigned logic circuits, there may exist logic value constraints on some part of primary inputs due to various requirements on design and test. This paper presents a logic value system called taboo logic values which targets the test pattern generation of logic circuits under logic value constraints. The taboo logic system represents the logic value constraints and identifies additional logic value constraints through the implication of the tqaboo logic values using a taboo logic calculus. Those identified logic value constraints will guide the search during the test pattern generation of avoid the unfruitful searches and to identify redundant faults due to the logic value constraints very quickly. Finally, experimental results on ISCAS85 benchmark circuits will demonstrate the efficiency of the taboo logic values.

  • PDF

Noise Test and Evaluation of a 750 kW Wind Turbine Generator (750 kW 풍력발전기의 소음 실증)

  • Kim, Seock-Hyun;Kim, Tae-Hyung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.124-131
    • /
    • 2006
  • This study introduces an environmental noise evaluation procedure for wind turbines(W/T) and the evaluation result of a 750 kW wind turbine(W/T) system. Test and evaluation are performed according to the international standard IEC 61400-11 on J48 W/T which is under operation in Daekwanryung W/T test site. With the meteorological data and W/T operational data, noise data are monitored and analysed. An integrated monitoring system is constructed in the test site and is utilized for the evaluation. From the measured noise data, acoustic power level, directivity and tonality of the W/T are estimated under the wind speeds required fly the International standard. The purpose of the study is to establish an W/T noise evaluating system satisfying the international standard and to obtain noise data for home made 750 kW W/T.

Optimal Design of Accelerated Degradation Tests under the Constraint of Total Experimental Cost in the Case that the Degradation Characteristic Follows a Wiener Process (열화가 Wiener process를 따르는 경우의 비용을 고려한 가속열화시험 계획)

  • Lim, Heon-Sang
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.2
    • /
    • pp.117-125
    • /
    • 2012
  • For the highly reliable products, an accelerated degradation test (ADT) is a useful tool which has been employed in industry to obtain reliability-related information within an affordable amount of time and cost. In an ADT, as all other reliability tests, it is important to carefully design the ADT beforehand to obtain estimates of the quantities of interest as precisely as possible. In this paper, optimal ADTs are developed assuming that the constant-stress loading method is employed and the degradation characteristic follows a Wiener process. Under the constraint that the total cost does not exceed a pre-specified budget, the stress levels, the number of test units allocated to each stress level and the number of measurement (termination time) are determined such that the asymptotic variance of the maximum likelihood estimator of the q-th quantile of the lifetime distribution at the use condition is minimized.

Environmental effects by corona discharge from a 765kV double circuit transmission line (765kV 2회선 송전선의 코로나 방전에 의한 환경영향 연구)

  • 김정부;이동일;신구용;양광호;안희성;구자윤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.451-455
    • /
    • 1996
  • This paper specified the measurement results conducted by the Korea Electric Power Research Institute (KEPRI) 765kV double circuit transmission test line that measured the audible noise, hum noise, radio interference, electric field and aeolian measurement. This test line consists of 6-480mm$^{2}$ conductors per phase. The analysis of the test results shows that this 6-Rail conductor bundle satisfies the audible noise criterion under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion. (author). 9 refs., 7 figs., 2 tabs.

  • PDF