• 제목/요약/키워드: Under ventilated fire

검색결과 24건 처리시간 0.021초

환기부족 구획화재의 열적 특성 (Thermal Characteristics of Under Ventilated Compartment Fire)

  • 김성찬
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.41-48
    • /
    • 2009
  • The present study has been performed to investigate the thermal characteristics of under-ventilated compartment fire which is a typical fire condition in structures. A series of fire experiments was conducted to characterize the thermally driven flow in a 2/5 scale ISO 9705 fire compartment. Three different fuels were used in this test series, methane gas, heptane pool, and polystyrene pellets fire. In order to measure accurate temperature, double shield aspirated thermocouples reducing the effect of radiative energy exchange on temperature measurement were used in addition to bare bead thermocouples. The upper layer temperature for well ventilated fire was increased with increasing heat release rate, but it was slightly decreased for under-ventilated fire. The measured temperatures in the upper layer at the front sampling location were higher than at the rear. Thermal characteristics through the doorway were also analysed for a wide range of heat release rates. This study provides a comprehensive and quantitative assessment of fire behavior for under-ventilation condition of fire.

환기부족 화재의 시뮬레이션 (Simulation of Under-Ventilated Fires)

  • 박외철
    • 한국화재소방학회논문지
    • /
    • 제30권1호
    • /
    • pp.12-16
    • /
    • 2016
  • FDS를 사용한 환기부족 화재 시뮬레이션의 문제점을 재확인하고 FDS의 환기부족 화재 판단기준을 제시하기 위하여 ISO 9705 화재실 내 1000~3000 kW의 프로판 화재에 대한 시뮬레이션을 수행하였다. 화재규모가 2000 kW 이상일 때 1500 kW의 경우보다 온도가 낮게 예측됨을 확인하였다. FDS를 사용할 때 환기부족 화재에서는 화재규모가 증가해도 산소부족으로 열방출률은 증가하지 않았다. 이에 따라 화재 시뮬레이션에 있어서의 환기부족 화재 판단기준으로 열방출률이 사용될 수 있으며, ISO 9705 화재실에서는 화재규모가 1700 kW 이상일 때 환기부족 화재가 예측됨을 알 수 있었다.

원자력발전소의 다중 구획에서 화재특성 예측을 위한 FDS 검증 (Part II: 환기부족화재 조건) (Validation of FDS for Predicting the Fire Characteristics in the Multi-Compartments of Nuclear Power Plant (Part II: Under-ventilated Fire Condition))

  • 문선여;황철홍;박종석;도규식
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.80-88
    • /
    • 2013
  • 원자력발전소의 밀폐된 다중 구획에서 환기부족화재에 대한 FDS 검증이 수행되었다. 수치결과는 OECD/NEA PRISME 프로젝트를 통해 얻어진 실험결과와 비교되었다. 환기시스템의 수치 경계조건 및 FDS에 적용된 소화모델이 구획 내부의 열적 및 화학적특성에 미치는 영향이 상세히 논의되었다. 점화 및 소화 단계에서 구획 내부의 급격한 압력변동에 의해 변화될 수 있는 환기 유량의 수치 경계조건은 다중 구획 내부의 온도, 열유속에는 큰 영향을 주지 않지만, 농도의 정확한 예측을 위하여 주위 깊게 고려되어야 한다. FDS에 적용된 소화모델의 기본값은 인위적인 소화 및 재점화 현상을 동반하며, 해당 연료에 대한 수정된 소화모델의 정보가 적용되었을 때 환기부족화재에 대한 FDS의 결과는 실험결과를 매우 잘 예측하고 있음을 확인하였다.

환기부족 구획화재에 대한 FDS 해석 및 검증 (FDS Simulation and Validation on the Under-Ventilated Compartment Fires)

  • 고권현;김성찬;;유홍선
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.103-109
    • /
    • 2009
  • 본 연구에서는 환기부족 조건의 구획화재에 대하여 FDS(Ver. 5.2)를 이용하여 수치해석을 수행하였고 열적 특성 및 연소 가스 생성 특성에 대한 예측성능을 평가하였다. ISO-9705 표준화재실의 2/5 크기 모형에 대한 메탄 및 헵탄, 톨루엔 화재를 모사하였으며 고온 상층부의 온도, 연소가스 농도 등에 대하여 기존의 실험 결과와 비교하였다. 실험결과와의 비교를 통해 FDS가 천정의 온도와 과환기 조건의 혼합분율의 예측에 있어서 좋은 성능을 보임을 확인할 수 있었다. 그러나 화재 크기에 비해 산소의 유입량이 충분치 않은 환기부족 조건에서는 일산화탄소 및 그을름의 발생량을 실험값에 비해 크게 하향 예측하였다.

워터미스트 작동에 의한 산소저공급 실내화재 특성 변화에 대한 수치해석 연구 (Numerical Study on the Change in Fire Characteristic as Operating Water-mist in Under-ventilated Compartments)

  • 고권현;이성혁;유홍선
    • 한국분무공학회지
    • /
    • 제13권3호
    • /
    • pp.156-161
    • /
    • 2008
  • The present article reports a numerical study on the fire characteristic change by water-mist in under-ventilated compartments. The natural gas and heptane pool fires are used as fire sources, which are located in the bottom center of the 2/5 reduced-scaled model of the ISO 9705 standard room. The fire modeling using the FDS (Fire Dynamics Simulator) is validated by comparison with previously published experimental results. For temperature and combustion gas concentrations at two positions located in the upper layer of compartment, the predicted results with and without water-mist are compared each other. The results show that under the water-mist operation, the predicted temperature and carbon monoxide concentration reduce as $300{\sim}400^{\circ}C$ and about 20%, respectively, compared to those without water-mist.

  • PDF

환기 조건에 따른 화재거동 연구 (On the Fire Behavior Due to the Ventilation Condition in the Fire Compartment)

  • 김성찬
    • 대한기계학회논문집B
    • /
    • 제32권5호
    • /
    • pp.367-373
    • /
    • 2008
  • A series of fire experiments has been conducted to provide an improved understanding of the fire structure of under-ventilated compartment fires. A comprehensive and quantitative assessment of gaseous species from the fire was made in the upper layer of fire in a 40 % reduced scale ISO 9705 fire compartment. The global equivalence ratio (GER) concept was used to characterize the fire behavior for various fire sizes, fuel types and ventilation conditions. The oxygen concentration in the upper layer reached to zero near the global equivalence ratio of $0.4{\sim}0.6$ while the carbon monoxide concentration increases with increasing the global equivalence ratio. Classification parameters of ISO19706 were also compared with the reduced scale experimental data for under ventilation fire.

환기부족 구획화재에서 다차원 화재거동 (Multi-dimensional Fire Behaviors in an Under-ventilated Compartment Fire)

  • 황철홍;박충화;고권현
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.37-42
    • /
    • 2010
  • 실제 규모 ISO 9705 표준 화재실에서 과환기(over-ventilated) 및 환기부족(under-ventilated) 화재에 대한 열 및 화학적 특성에 관한 실험이 수행되었다. 또한 FDS(Fire Dynamic Simulator)를 이용하여 수치적 예측성능에 대한 평가와 환기부족화재에서 건물 내부의 다차원 화재현상에 대한 해석이 이루어졌다. 과환기 및 환기부족화재의 특성은 연소효율, 총괄 당량비 뿐만 아니라 고온 상층부의 온도분포, 연소 생성물의 농도에 의해 명확하게 구분되었다. 실험결과와의 비교를 통해 과환기 및 환기부족화재에서 FDS는 공간내부의 온도, 열유속 및 다양한 화학종의 분포를 정량적으로 잘 예측함을 확인하였다. 과환기화재와 비교할 때, 환기부족화재에서 내부유동은 반대방향의 다차원 재순환 유동구조를 갖고 있음을 발견하였다. 동시에 공간내부의 $O_2$ 및 CO의 분포 역시 다차원 구조를 갖기 때문에 기존화재연구에서 측정되는 고온 상층부의 열 및 화학적 특성은 환기부족화재를 이해하는데 많은 한계가 있음을 확인하였다.

  • PDF

환기가 제한된 두 개 격실 화재에서 FDS 검증분석 (Validation of FDS for Fire in Underventilated Condition with Two rooms)

  • 배용범;금오현;김윤일;류수현;김위경;박종석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.438-443
    • /
    • 2008
  • Fire model shall be verified and validated to reliably show the predictive capabilities for a specific use. In the process of model verification and validation, both the acceptable uses and limitation of fire model are established. In this study, the results of FDS simulation are compared with the data of PRISME experiment such as temperature, heat release rate, heat flux, product concentrations in the under-ventilated two-room condition. Furthermore, the sensitivity of FDS under ventilation condition changes are evaluated. FDS provide the reliable prediction for under-ventilated two-room fire scenario with slightly deviation.

  • PDF

반밀폐된 ISO 9705 화재실에서 비정상 화재특성 예측을 위한 FDS의 성능평가 (Performance Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed ISO 9705 Room)

  • 문선여;황철홍
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.21-28
    • /
    • 2012
  • 비정상(unsteady) 화재성장이 발생되는 반밀폐된 구획에서 환기부족화재의 열 및 화학적 특성에 관한 FDS(Fire Dynamics Simulator)의 예측성능 평가가 수행되었다. 이를 위해 실규모 ISO 9705 표준 화재실의 출입구 폭이 0.1 m로 축소되었으며, spray 노즐을 통해 Heptane 연료유량은 선형적으로 증가되었다. 수치계산에 대한 신뢰도 확보를 위하여 동일 조건에서 수행된 실험결과와의 상세한 비교가 이루어졌다. 적절한 격자계를 이용한 FDS의 결과는 구획 내부의 온도 및 열유속(heat flux)은 비교적 잘 예측하지만, 비정상 CO 및 $CO_2$ 생성특성은 적절히 예측하지 못함을 확인하였다. 이러한 결과는 최근 수행된 유사조건의 정상상태 환기부족 구획화재에 대한 FDS 예측결과와 상반된 것으로서, 반밀폐된 구획화재 모델링에서 FDS를 이용한 비정상 CO 생성특성 예측에 상당한 주위가 요구됨을 확인하였다.

환기부족 구획화재에서 수직 개구부의 형상 및 위치가 화재특성에 미치는 영향 (Effects of the Geometry and Location of an Vertical Opening on the Fire Characteristics in the Under-Ventilated Compartment Fire)

  • 문선여;박충화;황철홍;박설현
    • 한국화재소방학회논문지
    • /
    • 제27권3호
    • /
    • pp.20-29
    • /
    • 2013
  • 실규모 환기부족 구획화재에서 수직 개구부의 형상 및 위치변화에 따른 열 및 화학적 화재특성 변화를 수치적으로 검토하기 위하여, 이론적 최대 공기 유입량을 결정하는 환기인자($A\sqrt{h}$)와 heptane pool 화재의 질량 감소율이 모든 조건에 대하여 동일하게 설정되었다. 주요 결과로서, 출입문 형상의 변화는 구획 내부의 열 및 화학적특성 변화에 큰 영향을 미친다. 창문 위치의 변화는 화재지속시간 및 재순환 유동구조를 포함한 추가적인 화재특성의 복잡한 변화를 초래하였다. 이들 결과는 개구부 유동 및 연료/공기의 혼합현상을 포함한 다차원 유동 및 화재특성을 통해 상세히 분석되었다.