• Title/Summary/Keyword: Under correction

Search Result 838, Processing Time 0.025 seconds

Comparison of Drift Reduction Methods for Pedestrian Dead Reckoning Based on a Shoe-Mounted IMU

  • Jung, Woo Chang;Lee, Jung Keun
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.345-354
    • /
    • 2019
  • The 3D position of pedestrians is a physical quantity used in various fields, such as automotive navigation and augmented reality. An inertial navigation system (INS) based pedestrian dead reckoning (PDR), hereafter INS-PDR, estimates the relative position of pedestrians using an inertial measurement unit (IMU). Since an INS-PDR integrates the accelerometer signal twice, cumulative errors occur and cause a rapid increase in drifts. Various correction methods have been proposed to reduce drifts. For example, one of the most commonly applied correction method is the zero velocity update (ZUPT). This study investigated the characteristics of the existing INS-PDR methods based on shoe-mounted IMU and compared the estimation performances under various conditions. Four methods were chosen: (i) altitude correction (AC); (ii) step length correction (SLC); (iii) advanced heuristic drift elimination (AHDE); and (iv) magnetometer-based heading correction (MHC). Experimental results reveal that each of the correction methods shows condition-sensitive performance, that is, each method performs better under the test conditions for which the method was developed than it does under other conditions. Nevertheless, AC and AHDE performed better than the SLC and MHC overall. The AC and AHDE methods were complementary to each other, and a combination of the two methods yields better estimation performance.

Effect of Under and Over Refractive Correction on Visual Acuity Performance using Two Different Charts

  • Chen, Ai-Hong;Shah, Siti Salwa Mohamad;Rosli, Saiful Azlan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.291-295
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the effect of under and over refractive correction on visual acuity performance and the variation of the visual performance measurement using two different visual acuity charts. Methods: Ten young adults, aged between 19 and 25 years old, were recruited. Inclusion criteria: no history of ocular injury or pathology with a best-corrected visual acuity of 6/6 on dominant eye. The over and under refractive corrections were induced using minus and plus spherical ophthalmic lenses in 0.50 D steps up to 3.00 D; as well as using three axis orientations of cylindrical ophthalmic lenses ($45^{\circ}$, $90^{\circ}$ and $180^{\circ}$) in 0.50 D steps. The variation of visual acuity performance measurements was investigated using Bailey-Lovie LogMAR chart and Landolt C chart. Results: The visual acuity changes with lenses were significantly different between two charts [F = 49.15, p < 0.05 with plus spherical ophthalmic lenses and F = 174.38, p < 0.05 with minus spherical ophthalmic lenses]. The visual acuity changes with three different cylindrical axis showed no significant difference between Bailey-Lovie LogMAR chart [F = 2.35, p > 0.05] and Landolt C chart [F = 3.12, p = 0.05]. Conclusions: The over and under refractive correction affected the visual acuity performance differently. The Landolt C chart and Bailey-Lovie LogMAR chart demonstrated variation in measurements.

Development of Critical Heat Flux Correction Factor for Water under Flow Oscillation Conditions

  • Kim, Yun-Il;Baek, Won-Pil;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.242-247
    • /
    • 1996
  • Flow oscillations in boiling channels induces a drastic reduction of the (critical heat flux) CHF or premature burnout. However, most of CHF works and correlations have been focused on stable flow conditions without considering flow oscillation. Therefore to improve the understanding on flow oscillation CHF, in this paper a new CHF correction factor to predict the CHF values under flow oscillation conditions has been developed from 126 experimental data. Also to investigate the dominant factor on flow oscillation CHF parametric trends are analyzed by using the developed correction factor. The overall mean accuracy ratio of the developed correction factor is 1.033 with a standard deviation of 0.195. The RMS errors 0.198. Its assessment shows that the predictions agree well with the experimental data within 25% error bounds.

  • PDF

A New High Power Factor ZVT-ZCT AC-DC Boost Converter

  • Ting, Naim Suleyman
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1539-1548
    • /
    • 2018
  • This paper introduces a new soft switched AC-DC boost converter with power factor correction (PFC). In the introduced converter, all devices are turned on and off under soft switching (SS). The main switch is turned on under zero voltage transition (ZVT) and turned off under zero current transition (ZCT). The main diode is turned on under zero voltage switching (ZVS) and turned off under zero current switching (ZCS). Meanwhile, there is not any current or voltage stress on the main devices. Besides, the auxiliary switch is turned on under ZCS and turned off under ZVS. The detailed theoretical analysis of the converter is presented, and also theoretical analysis is verified by a prototype with 100 kHz and 500 W. Also, the proposed converter has 99.8% power factor and 97.5% total efficiency at soft switching operation.

Two-Dimensional Image-Based Respiratory Navigator for Free-Breathing Coronary Magnetic Resonance Angiography

  • Shin, Taehoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.71-77
    • /
    • 2018
  • Purpose: To develop a two-dimensional (2D) image-based respiratory motion correction technique for free-breathing coronary magnetic resonance angiography (MRA). Materials and Methods: The proposed respiratory navigator obtained aliased a 2D sagittal image from under-sampled k-space data and utilized motion correlation between the aliased images. The proposed navigator was incorporated into the conventional coronary MRA sequence including the diaphragm navigator and tested in three healthy subjects. Results: The delineation of major coronary arteries was significantly improved using the proposed 2D motion correction (S/I and A/P) compared to one-dimensional (S/I) correction using the conventional diaphragm navigator. Conclusion: The 2D image-based respiratory navigator was proposed for free-breathing coronary angiography and showed the potential for improving respiratory motion correction compared to the conventional 1D correction.

AN APPROXIMATED EUROPEAN OPTION PRICE UNDER STOCHASTIC ELASTICITY OF VARIANCE USING MELLIN TRANSFORMS

  • Kim, So-Yeun;Yoon, Ji-Hun
    • East Asian mathematical journal
    • /
    • v.34 no.3
    • /
    • pp.239-248
    • /
    • 2018
  • In this paper, we derive a closed-form formula of a second-order approximation for a European corrected option price under stochastic elasticity of variance model mentioned in Kim et al. (2014) [1] [J.-H. Kim, J Lee, S.-P. Zhu, S.-H. Yu, A multiscale correction to the Black-Scholes formula, Appl. Stoch. Model. Bus. 30 (2014)]. To find the explicit-form correction to the option price, we use Mellin transform approaches.

Congenital Constriction Band Syndrome of Hand ; The Correction Under The Microscope (선천성 수부 윤상 수축대 증후군에 대한 미세현미경을 이용한 수술적 교정)

  • Hwang, Ho;Kim, Yong-Kyu;Whang, Jong-Ick
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.70-76
    • /
    • 2005
  • The Z-plasty has been known as a most common surgical treatment of congenital circumferential constriction band syndrome of the hand. There were thirteen patients of congenital circumferential constriction band syndrome of the hand. All patients underwent Z-plasty under microscope. we did microsurgical dissection to minimize vascular, neural and lymphatic injury, and then considering secondary correction and scar contracture, tried to preserve as much subcutaneous fat and skin flap as possible without any excision. There were less skin necrosis and lymphedema as a result of vascular compromise. Using microscope offers several advantages. First, preventing vascular, neural and lymphatic injury. Second, getting an accurate suture approximation. finally, preserving as much subcutaneous fat and skin flap as possible without any excision. The outcome of digit growth and contour can be excellent than we expected. As a results, we believe that correction of congenital circumferential constriction band syndrome of the hand under the microscope have better results.

  • PDF

Assessment of microclimate conditions under artificial shades in a ginseng field

  • Lee, Kyu Jong;Lee, Byun-Woo;Kang, Je Yong;Lee, Dong Yun;Jang, Soo Won;Kim, Kwang Soo
    • Journal of Ginseng Research
    • /
    • v.40 no.1
    • /
    • pp.90-96
    • /
    • 2016
  • Background: Knowledge on microclimate conditions under artificial shades in a ginseng field would facilitate climate-aware management of ginseng production. Methods: Weather data were measured under the shade and outside the shade at two fields located in Gochang-gun and Jeongeup-si, Korea, in 2011 and 2012 seasons to assess temperature and humidity conditions under the shade. An empirical approach was developed and validated for the estimation of leaf wetness duration (LWD) using weather measurements outside the shade as inputs to the model. Results: Air temperature and relative humidity were similar between under the shade and outside the shade. For example, temperature conditions favorable for ginseng growth, e.g., between $8^{\circ}C$ and $27^{\circ}C$, occurred slightly less frequently in hours during night times under the shade (91%) than outside (92%). Humidity conditions favorable for development of a foliar disease, e.g., relative humidity > 70%, occurred slightly more frequently under the shade (84%) than outside (82%). Effectiveness of correction schemes to an empirical LWD model differed by rainfall conditions for the estimation of LWD under the shade using weather measurements outside the shade as inputs to the model. During dew eligible days, a correction scheme to an empirical LWD model was slightly effective (10%) in reducing estimation errors under the shade. However, another correction approach during rainfall eligible days reduced errors of LWD estimation by 17%. Conclusion: Weather measurements outside the shade and LWD estimates derived from these measurements would be useful as inputs for decision support systems to predict ginseng growth and disease development.

Surgical Correction of Funnel Chest by using Sulamaa`s metal strut (누두흉의 외과적 치료Metal bar 를 이용한 수술 1례 치험)

  • 손동섭
    • Journal of Chest Surgery
    • /
    • v.18 no.3
    • /
    • pp.492-496
    • /
    • 1985
  • Two cases of surgical correction of funnel chest using metal struts were presented. The main procedures of the method were transverse submammary incision, subperichondrial resection of the deformed costal cartilages, division of the xiphisternal joint, wedge osteotomy of the sternum, freeing of the posterior surface of the sternum and stabilization by means of 2 metal struts. The struts were removed postoperative 3 and 6 months by a small incision under the local anesthesia. The results in both patients were satisfactory. This method of correction is simple, easy to perform and free of any operative risks.

  • PDF

Design of Power Factor Correction IC for 1.5kW System Power Module (1.5kW급 System Power Module용 Power Factor Correction IC 설계)

  • Kim, Hyoung-Woo;Seo, Kil-Soo;Kim, Ki-Hyun;Park, Hyun-Il;Kim, Nam-Kyun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.499-500
    • /
    • 2008
  • In this paper, we design and implement the monolithic power factor correction IC for system power modules using a high voltage(50V) CMOS process. The power factor correction IC is designed for power applications, such as refrigerator, air-conditioner, etc. It includes low voltage logic, 5V regulator, analog control circuit, high-voltage high current output drivers, and several protection circuits. And also, the designed IC has standby detection function which detects the output power of the converter stage and generates system down signal when load device is under the standby condition. The simulation and experimental results show that the designed IC acts properly as power factor correction IC with efficient protective functions.

  • PDF