• Title/Summary/Keyword: Uncertainty measurement

Search Result 931, Processing Time 0.024 seconds

Low Fiele Measurement of 0.1 mT by Rabi's NMR Method (Rabi법 핵자기 공명에 의한 0.1 mT의 저자장 측정)

  • 유권상;김철기;우병칠;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.2
    • /
    • pp.139-142
    • /
    • 1993
  • The Rabi's NMR experiment using polarized flowing water was performed in order to measure the low field and the good NMR signal was obtained in the range of 0.1 mT. There was a change in amplitude and phase of signal due to the sinusoidal variation with the increasing RF field. The nominal field could be determined within a few tens ppm uncertainty by the NMR signal under the optimized RF condition.

  • PDF

A Theoretical Study on Risk - focused on systematic risk- (위험에 관한 이론적 연구 -체계적 위험을 중심으로-)

  • 김원기
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.2 no.2
    • /
    • pp.115-124
    • /
    • 1979
  • The purpose of this study is theoretical research on risk. The research is focused on systematic risk. Chapter I is objective of this study, Chapter II includes definition and measurement of risk. Chapter III introduces attitudes toward risk and classification of risk. Chapter IV discusses Portfolio theory, Capital market line and Shape and Lintner model The objective of firm is assumed to maximize its value. In a world of uncertainty, value is not determined by earnings alone, the degree of risk involved with the streams of earnings. Financial manager has to consider the risk in order to maximize the value of firm. Total risk can be classifier into two parts : Systematicrisk and unststematic risk by Sharpe. Systematic risk is important because investors can't diversify it. Blume and Jensen measured f and they testified that the f is stationary over the time For further study, Korean stock mark has to take emperical study about $\beta$ and its stationarity.

  • PDF

Measurement of Cavitation-Induced Pressure Fluctuation in a Large Cavitation Tunnel (대형 공동 수조에서의 변동 압력 계측)

  • Na, Yun-Cheol;Kang, Kwan-Hyoung;Kim, Young-Gi;Lee, Mu-Yeol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.791-796
    • /
    • 2000
  • The cavitation-induced fluctuating pressure of the container ship named "Sydney Express" is measured in Samsung Large Cavitation Tunnel(SCAT). In the measurements, a complete ship model is employed. The effects of thrust coefficient and cavitation number on cavity pattern and cavitation-induced fluctuating pressure were investigated experimentally. It is demonstrated that the fluctuating pressure coefficient is very sensitive to the cavitation number. The results of cavitation and pressure fluctuations are compared with those of ITTC and HSVA, which shows fairly good agreement. It is exhibited that the removal of rudder can significantly change the loading condition of a propeller, and can reduce the fluctuating pressure coefficient almost by half.

  • PDF

An Optimal FIR Filter for Discrete Time-varying State Space Models (이산 시변 상태공간 모델을 위한 최적 유한 임펄스 응답 필터)

  • Kwon, Bo-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.12
    • /
    • pp.1183-1187
    • /
    • 2011
  • In this paper, an optimal FIR (Finite-Impulse-Response) filter is proposed for discrete time-varying state-space models. The proposed filter estimates the current state using measured output samples on the recent time horizon so that the variance of the estimation error is minimized. It is designed to be linear, unbiased, with an FIR structure, and is independent of any state information. Due to its FIR structure, the proposed filter is believed to be robust for modeling uncertainty or numerical errors than other IIR filters, such as the Kalman filter. For a general system with system and measurement noise, the proposed filter is derived without any artificial assumptions such as the nonsingular assumption of the system matrix A and any infinite covariance of the initial state. A numerical example show that the proposed FIR filter has better performance than the Kalman filter based on the IIR (Infinite- Impulse-Response) structure when modeling uncertainties exist.

Improvement of Field Calibration of a Transmissometer for Visibility Measurement

  • Kim Kyung W.;Kim Young J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E2
    • /
    • pp.49-56
    • /
    • 2005
  • A long-path transmissometer is one of the optical instruments widely used to measure atmospheric light extinction coefficient without enclosing a light beam and perturbing aerosols. Over the past two decades, a number of measurements have been carried out using the long-path transmissometer manufactured by OPTEC, Inc. Calibration of the transmissometer should be performed when any component of the transmissometer system is interchanged or installation condition is changed. For a better calibration of the transmissometer, application of a modified calibration method for the existing neutral density (ND)-filter method was recommended for the computation of the atmospheric transmittance using model MODTRAN 4 in this study. It was revealed that the measured light extinction coefficient from the transmissometer which was calibrated using the existing ND-filter method could be overestimated due to the assumption of the atmospheric transmittance suggested by OPTEC, Inc. The uncertainty of the measured light extinction coefficient from the transmissometer calibrated based on the modified ND-filter method was calculated to be approximately $13Mm^{-1}$.

Development of Rating Curves Using a Maximum Likelihood Model (최우도 모형을 이용한 수위-유량곡선식 개발)

  • Kim, Gyeong-Hoon;Park, Jun-Il;Shin, Chan-Ki
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.83-93
    • /
    • 2008
  • The non-linear least squares model(NLSM) has long been the standard technique used by hydrologists for constructing rating curves. The reasons for its adaptation are vague, and its appropriateness as a method of describing discharge measurement uncertainty has not been well investigated. It is shown in this paper that the classical method of NLSM can model only a very limited class of variance heterogeneity. Furthermore, this lack of flexibility often leads to unaccounted heteroscedasticity, resulting in dubious values for the rating curve parameters and estimated discharge. By introducing a heteroscedastic maximum likelihood model(HMLM), the variance heterogeneity is treated more generally. The maximum likelihood model stabilises the variance better than the NLSM approach, and thus is a more robust and appropriate way to fit a rating curve to a set of discharge measurements.

수중운동의 표적추적성능 해석과 제어기 설계

  • 윤강섭;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.330-335
    • /
    • 1995
  • The actuator's response delay, disturbance and measurement noise can often cause a significant error in the target tracking of an underwater vehicle. The first purpose of this paper is error analysis about motion of an underwater vehicle when the closed loop system has actuator and disturbance and noise. The underwater vehicle is simulated for cases of various disturbances. The second purpose is robust controller design for the underwater vehicle with parameter uncertainty. So, two robust control methods are applied for the underwater vehicle. One is standard $H_{\infty}$ control, and the other is time-varying sliding mode control with modified saturation function. Suboptimal design parameters for $H_{\infty}$ control, and design parameters for time-varying switching surfaces are provided Simulations for the two controllers are carried out and their performances are analyzed.lyzed.

  • PDF

Prediction of Wind Power Generation at Southwest Coast of Korea Considering Uncertainty of HeMOSU-1 Wind Speed Data (HeMOSU-1호 관측풍속의 불확실성을 고려한 서남해안의 풍력 발전량 예측)

  • Lee, Geenam;Kim, Donghyawn;Kwon, Osoon
    • New & Renewable Energy
    • /
    • v.10 no.2
    • /
    • pp.19-28
    • /
    • 2014
  • Wind power generation of 5 MW wind turbine was predicted by using wind measurement data from HeMOSU-1 which is at south west coast of Korea. Time histories of turbulent wind was generated from 10-min mean wind speed and then they were used as input to Bladed to estimated electric power. Those estimated powers are used in both polynominal regression and neural network training. They were compared with each other for daily production and yearly production. Effect of mean wind speed and turbulence intensity were quantitatively analyzed and discussed. This technique further can be used to assess lifetime power of wind turbine.

A Study on Sensitivity Analysis for Process Parameters in GMA Welding Processes

  • Kim, Ill-Soo;Park, Chang-Eun;An, Young-Ho;Park, Ju-Seog;Chon, Kwang-Suk;Jeong, Young-Jae
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.29-31
    • /
    • 2003
  • Generally, the Quality of a weld joint is strongly influenced by process parameters during the welding process. In order to achieve high quality welds, mathematical models that can predict the bead geometry to accomplish the desired mechanical properties of the weldment should be developed. To achieve this objectives, a sensitivity analysis has been conducted and compared the relative impact of three process parameters on bead geometry in order to verify the measurement errors on the values of the uncertainty in estimated parameters. The results obtained show that developed mathematical models can be applied to estimate the effectiveness of process parameters for a given bead geometry, and a change of process parameters affects the bead width and bead height more strongly than penetration relatively.

  • PDF

Investigating Uncertainty in Flow Measurement and Developing Rating Curves (유량측정시 불확실성의 검토와 수위-유량곡선식의 개발)

  • Lee, Kil Seong;Lee, Kyung Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1242-1246
    • /
    • 2004
  • 본 연구에서는 유속계와 봉부자를 동한 측정값의 불확실성를 검토한 후, 한강의 7개 지류의 실측 자료들의 불확실성을 ISO 규정을 통하여 추정하였다. Simulated Annealing 기법과 황금비 분할법을 이용한 비선형회귀식을 적용하여 기존의 수위-유량 곡선식자 비교해보았다. 불확실성 추정결과 유량 측정치들의 불확실성이 ISO 규정의 기준에 비해 높게 추정되었으며, 특히 무작위 오차와 계통 오차 중에 무작위 오차의 불착실성이 높게 나타났다. 또한, 기존 수위-유량곡선식과 Simulated Annealing 기법과 황금비 분할법을 이용한 방법을 비교해본 결과 황금비 분할법이 가장 좋은 결과를 얻었다. 이때 수위-유량곡선식의 영수위값을 황금비 분할법을 이용해 구한 후 비교해 본 결과는 기존의 선형회귀방법과 비선형방법에서 큰 차이를 보이지 않았다. 또한 곡선 분리시에는 하나의 수위-유량곡선일때보다 오차가 줄어드는 경향을 보였다.

  • PDF