• Title/Summary/Keyword: Uncertainty measurement

Search Result 930, Processing Time 0.03 seconds

Sustained Stress Measurement on Concrete Structures By a Partial Sectioning Method (부분절단법에 의한 콘크리트 구조물의 지속응력 측정에 관한 연구)

  • Min, Ho-Ki;Park, Dae-Sung;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.749-754
    • /
    • 1998
  • This study describes a practical method for the measurement of sustained stress in concrete structures. In most cases, the sustained stress was determined by various theoretical calculation. However, the theoretical calculation can not always provide a sufficient information on the current stress state due to lots of uncertainty. Therefore, the present study proposes a practical in situ measuring method, Partial Sectioning Method

  • PDF

The Sustained Stress Measurement on Deterioration of Concrete Structures by Experimental Technique (노후화 교량의 콘크리트 지속응력에 관한 실험적 평가방법)

  • Park, Dae-Sung;Myung, Gun-Hak;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.667-670
    • /
    • 2004
  • This study describes a practical method of measurement of the sustained stress in concrete structures. In most cases, the sustained stress was determined by various theoretical calculations. However, the theoretical calculations can not always provide sufficient informations about current stress state having lots of uncertainty. Therefore, the present study proposes a practical measuring method, Partial Sectioning Method.

  • PDF

Uncertainty of Online TOC Analyzer in Water Quality Monitoring System (수질자동측정시스템에서 온라인 TOC 자동측정장치의 불확도 산출)

  • Lee, Chung-Yul;Lee, Yong-Woon;Lee, Jun-Hung;Lim, Boung-Jin;Kwon, Young-Jin;Khang, Bum-Ju;Hong, Young-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.2
    • /
    • pp.193-200
    • /
    • 2007
  • The objective of this study was to estimate uncertainty of online TOC analyzer in water quality monitoring system. A procedure for the estimation of measurement uncertainty of total organic compounds (TOC) based on the ISO approach is presented. It is based on a mathematical model that involves 4 input parameters (standardization, sensitivity, solute effect and representativeness). In this study, a major problem in estimating the uncertainty of online TOC analyzer was the solute effect. It was strongly depends on organic materials. So homogeneity of the sample is the most important consideration. Modified concentration and combined standard uncertainty was $4.71{\pm}0.36$ mg $L^{-1}$ by model modified in this study.

An Evaluation of Uncertainty for Reference Standards Solar Radiation Data (참조표준 일사량 데이터에 대한 불확도 평가)

  • Kim, Sang-Yeob;Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • The energy makes the basic element which improves the quality of life with motive power of industry and life. However, using the fossil fuel resources was restricted through it's abuse and exhaustion, and that cause a global warming resultingly. According to the reason, the world increased the interest that are stability and use of new and renewable energy which is clean energy with environment. Therefore, the property data of new and renewable is needed for developing and supplying the energy. In other words, the data of new and renewable energy becomes the standards for supply and evaluation of new and renewable energy with development of industry and technology. Also, the necessity came to the fore as the reference and standards of new and renewable energy data. Therefore, in this study, we evaluate and collect the solar radiation data as the new and renewable data and process the collected data through the standards for valuation. We evaluate uncertainty with standards which are NREL, WMO, and GUM. Whereby the data becomes reference standards data and gains the credibility. For the reliability data, we correct the measuring instrument with correction period. Using the DQMS and SERI QC, we efficiently manage and evaluate the solar radiation data. As a result, we evaluate uncertainty as 1,120 case about 16 area. we achieve credibility of data from evaluated solar radiation data and provide an accurate information to user. The annual average of horizontal radiation presents between 1,484 and 4,577, then the uncertainty evaluates from 163 to 453. The error of uncertainty presents smaller than the measurement values. So, we judge a credibility of data by expression of reliability quantitatively. In additional, the reference standards data which is possible to approach anywhere will be used for the supporting related industry and policy making.

Modelling Method for Removing Measurement Uncertainty in Chip Impedance Characterization of UHF RFID Tag IC (UHF RFID 태그 칩의 임피던스 산출 불확실성 제거를 위한 모델링 방법)

  • Yang, Jeenmo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.12
    • /
    • pp.1228-1235
    • /
    • 2014
  • Input impedance of UHF RFID tag chip is needed to design a tag. In determining the chip impedance, direct measurement method is adopted commonly. In this paper, problems generated from fixtures that interface between tag chip and coaxial-oriented measurement instrument are investigated and the result of the problems is shown, when the direct measurement method is applied. As an alternative to the method, a modeling method is proposed and its validity and accuracy are shown.

Validation of Digital Holographic Particle Velocity Measurement System (디지털 홀로그래피 입자 속도 계측시스템의 검증)

  • Roh, H.S.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.18 no.3
    • /
    • pp.119-125
    • /
    • 2013
  • Digital holographic particle velocity measurement system can be a promising optical tool for the measurements of three dimensional particle velocities. In this research, validation experiments for the digital holographic particle velocity measurement system were conducted with measuring the velocities of glass beads on a rotating disk. Uncertainty analysis was performed to identify the sources of all relevant errors and to evaluate their magnitudes. The measurement results of particle velocities obtained with digital holographic method are compared reasonably well with the known values within acceptable range of errors. Moreover, digital holographic method showed better performance compared with that of optical holographic system.

Mass measuremeant of soilid density standard using weight exchanger (분동교환기를 이용한 고체밀도기준물의 질량측정)

  • 이용재;장경호;오재윤;정상덕
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1659-1662
    • /
    • 2003
  • The mass measurement of solid density standards using weight exchanger is described. KRISS(Korea Research Institute od Standards and Science) has several solid density standards. Their mass have been measured manually only using a mass comparator(Mettler, 1kg - 0.01mg). However, the uncertaity of the manual mass measurement is up to 300 microgarm much more than 32 microgram of advanced NMIS(National Metrology Institutes) for 1 kg silicon sphere which is primary density standards due to an eccentric error and buoyancy correction error. The new system with a weight exchanger is designed and built to improve the measurement accuracy. It comprises a weight exchager, a mass comparator, air density instruments, and application program for automatic measurement. It is evaluated by measuring several elements in an air tight chamber to verify the performance of it.

  • PDF

Development of On-machine Measurement System utilizing a Capacitive-type Sensor (정전용량형 센서를 이용한 기상계측시스템의 개발)

  • 김건희;박순섭;박원규;원종호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.391-395
    • /
    • 2002
  • This paper described about the ultra-precision profile measurement of aspheric surfaces using contact probing technique. A contact probe has been designed as a sensing device to obtain measuring resolutions in nanometer regime utilizing a leaf spring mechanism and a capacitive-type sensor. The contact probe is attached on the z-axis during measurement while aspheric objects are supported on the single point diamond turning machine(SPDTM). The machine xz-axis motions are monitored by a set of two orthogonal plane mirror type laser interferometers. Experimental results show that the contact probing technique developed of On-machine Measurement System in this investigation is capable of providing a repeatability of 20 nanometers with a $\pm$20 uncertainty of 300 nanometers.

  • PDF

The effect of diffusers on the measurement of sound absorption in a reverberation room (잔향실법 흡음률 측정에 미치는 확산체의 영향)

  • Han, Hee-Kab;Kim, Kyung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1194-1197
    • /
    • 2006
  • Recently, international standard for measurement of sound absorption in a reverberation room has been amended. In the revised version, temperature, humidity and air pressure conditions are strictly restricted and also the concrete procedures are presented to reduce the differences in test results by adding inspection of diffusion, measurement uncertainty etc. In this paper, the systematic tests are conducted based on the inspection guide of diffusion defined by ISO 354 and the effects of diffusers on the measurement of sound absorption ratio are considered. As a result, we perceived that the averaged sound absorption ratio in mid and high frequency range is expected to measure around $0.05{\sim}0.1$ higher in high sound absorption material. Therefore, as for the reverberation room for measurement of sound absorption, we need to take into consideration not only the spatial standard deviation of sound pressure mandated by ISO 3741, but also, inspection regulation of diffusion showed by ISO 354.

  • PDF

DC and AC Characterization of Metals Conductivity using the van der Pauw Measurement Method (Van der Pauw 측정법을 이용한 금속 도전율의 직류와 교류특성)

  • Kang, Jeon-Hong;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.157-160
    • /
    • 2007
  • The van der Pauw technique is one of the popular methods for determining the conductivity of flat metal samples. Traceability of the national standard for the conductivity has been achieved by direct current measurement techniques in national measurement institutes of many countries. But recently, alternative current measurement techniques for determining the conductivity of flat metal samples is also interested. In this study, we measured the conductivity of non-ferrous and ferrous flat metals at alternative current using van der Pauw technique. As measurement results, the conductivities of the samples were decreased according to increasing the test frequency even though the decreasing ratio was different.