• Title/Summary/Keyword: Uncertainty measurement

Search Result 936, Processing Time 0.03 seconds

A Calibration and Uncertainty Analysis on the Load Monitoring System for a Low Speed Shaft and Rotor Blade of a Wind Turbine (풍력발전기 주축 및 날개 부하 측정시스템의 보정 및 불확실성 해석)

  • Park Moo-Yeol;Yoo Neung-Soo;Nam Yoon-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.5 s.248
    • /
    • pp.560-567
    • /
    • 2006
  • The exact load measurements for the mechanical parts of a wind turbine are important step both fur the evaluation of a specific wind turbine design and for a certification process. A common method for a mechanical load measurement is using a strain gauge sensing. Two main problems ought to be answered in order for this method to be applied to the wind turbine project. These are strain gauge calibration and non-contact signal transmission from the strain gauge output to a load monitoring system. This paper suggests reliable solutions fer these two problems. A Bluetooth, a short range wireless data communication technology, is used to solve the second problem. The first one, the strain gauge calibration methodology for a load measurement in a wind turbine application, is fully explained in this paper. Various mechanical loadings for a strain gauge calibration in a wind turbine load measurement are introduced and analyzed. Initial experimental results which are obtained from a 1 kW small size wind turbine are analyzed, and the uncertainty problem in estimating mechanical loads using a calibration matrix is fully covered in this paper.

Measurement Method for Geometric Errors of Ultra-precision Roll Mold Machine Tool: Simulation (초정밀 롤 금형 가공기의 기하학적 오차 측정 방법: 모의실험)

  • Lee, Kwang-Il;Yang, Seung-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.10
    • /
    • pp.1087-1093
    • /
    • 2013
  • In this study, a measurement method of double ball-bar is proposed to measure the geometric errors of an ultra-precision roll mold machine tool. A volumetric error model of the machine tool is established to investigate the effects of the geometric errors to a radius error and a cylindricity of the roll mold. A measurement path is suggested for the geometric errors, and a ball-bar equation is derived to represent the relation between the geometric errors and a measured data of the double ball-bar. Set-up errors, which are inevitable at the double ball-bar installation, also are analyzed and are removed mathematically for the measurement accuracy. In addition, standard uncertainty of the measured geometric errors is analyzed to determine the experimental condition. Finally, the proposed method is tested and verified through simulation.

Development of the Modified Preprocessing Method for Pipe Wall Thinning Data in Nuclear Power Plants (원자력 발전소 배관 감육 측정데이터의 개선된 전처리 방법 개발)

  • Seong-Bin Mun;Sang-Hoon Lee;Young-Jin Oh;Sung-Ryul Kim
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.2
    • /
    • pp.146-154
    • /
    • 2023
  • In nuclear power plants, ultrasonic test for pipe wall thickness measurement is used during periodic inspections to prevent pipe rupture due to pipe wall thinning. However, when measuring pipe wall thickness using ultrasonic test, a significant amount of measurement error occurs due to the on-site conditions of the nuclear power plant. If the maximum pipe wall thinning rate is decided by the measured pipe wall thickness containing a significant error, the pipe wall thinning rate data have significant uncertainty and systematic overestimation. This study proposes preprocessing of pipe wall thinning measurement data using support vector machine regression algorithm. By using support vector machine, pipe wall thinning measurement data can be smoothened and accordingly uncertainty and systematic overestimation of the estimated pipe wall thinning rate data can be reduced.

Estimation of Measurement Uncertainty for the HPLC Analysis of Deoxynivalenol in Wheat (밀에서 HPLC에 의한 데옥시니발레놀 분석의 측정불확도 산정)

  • Ok, Hyun-Ee;Chang, Hyun-Joo;Ahn, Jang-Hyuk;Cho, Jae-Young;Chun, Hyang-Sook
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.258-264
    • /
    • 2009
  • The principal objective of this study was to estimate the measurement uncertainty associated with determination of deoxynivalenol (DON), a mycotoxin generated by Fusarium strain, in food. In service of this goal, wheat as a food matrix was analyzed via high performance liquid chromatography-ultraviolet (HPLC-UV) detection using an immunoaffinity column for clean-up. The uncertainty sources in the measurement process were identified by sample weight, final volume, and sample concentration in extraction volume with components including standard stock solution, working standard solution, 5 standard solutions, calibration curve, matrix, and instrument. The expanded uncertainty for DON at a concentration of 300 ${\mu}g/kg$ was estimated as 71.62 ${\mu}g/kg$ using a coverage factor of two, which provides a confidence level of approximately 95%. The most influential component in the uncertainty sources was the recovery of the wheat matrix, followed by the calibration curve. These results indicate that all efforts may be directed toward reducing the uncertainties of the recovery of the wheat matrix and the calibration curve to obtain a reliable HPLC-UV method for DON analysis in wheat.

Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of measuring uncertainty of AFM system (원자현미경용 XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 원자 현미경의 측정 불확도 평가)

  • Kim D.M.;Lee D.Y.;Gweon D.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1438-1441
    • /
    • 2005
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In this system, measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100um\times{100um}$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. Using this AFM system, 3um pitch specimen was measured. As a result, the uncertainty of total system has been evaluated.

  • PDF

Precision measurements of radiometric aperture area by laser spot scanning along the edge of the aperture (레이저 스폿의 칼날주사 방법에 의한 복사계 개구 면적의 정밀측정)

  • 강창호;김석원;박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.258-262
    • /
    • 2004
  • The uncertainty of the detector-based candela scale is limited by the area measurement uncertainty of radiometric apertures. The apertures were fabricated with a diamond-turning machine which trimmed the edge of the apertures as sharply as a knife edge. The positions of the apertures were controlled by a digital feedback algorithm to scan the laser spot with the beam waist less than 5 ${\mu}{\textrm}{m}$. The knife edge scan yielded a set of coordinates on the edges of the aperture. The areas of the apertures were obtained by fitting the coordinates to the ellipses. The relative standard uncertainty of the measurement was estimated to be 8${\times}$10$^{-5}$.

Uncertainty improvement in measurement of mean diameter of 0.3-$\mu\textrm{m}$-diameter polystyrene sphere by using quasi-elastic light scattering (준탄성광산란을 이용한 0.3 $\mu\textrm{m}$ 폴리스티렌구의 평균지름 측정 불확도 향상)

  • 박병천;정명세
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.258-263
    • /
    • 1998
  • Quasi-elastic light scattering is utilized to measure the mean diameter of the 0.3 $\mu\textrm{m}$-dimeter polystyrene sphere. The mean diameter of the polystyrene sphere is required to be known within the uncertainty of a few per centages. The systematic error has been considerably reduced by improving the system for the angle alignment and temperature measurement of cell. NIST SRM 1691 (0.269$\pm$0.007 $\mu\textrm{m}$: TEM; 0.275$\pm$0.007 $\mu\textrm{m}$: QELS) is measured to be 0.273 $\mu\textrm{m}$$\pm$0.006 $\mu\textrm{m}$ in mean diameter. Detailed description is given of the improved method and the resultant uncertainty, and the comparison of results with NIST is followed.

  • PDF

Design and Fabrication of K-band Attenuation Standard (K-대역 감소량 표준기의 설계 및 제작)

  • Lee Joo-Gwang;Kim Jeong-Hwan;Kang Jin-Seob;Kang Tae-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.387-392
    • /
    • 2006
  • In this paper, measurement scheme and uncertainty estimation of the K-band attenuation standard fitted with 3.5 mm coaxial connectors are described. The standard comprises a build-up chain of four steps of power ratio mea-surement and operates in the frequency range of 18 GHz to 26.5 GHz. The nominal attenuation of each step is around 20 dB and total dynamic range is 80 dB. The expanded uncertainty of the overall system is 0.01 dB at the confidence level of approximately 95%.

An Alternative State Estimation Filtering Algorithm for Temporarily Uncertain Continuous Time System

  • Kim, Pyung Soo
    • Journal of Information Processing Systems
    • /
    • v.16 no.3
    • /
    • pp.588-598
    • /
    • 2020
  • An alternative state estimation filtering algorithm is designed for continuous time systems with noises as well as control input. Two kinds of estimation filters, which have different measurement memory structures, are operated selectively in order to use both filters effectively as needed. Firstly, the estimation filter with infinite memory structure is operated for a certain continuous time system. Secondly, the estimation filter with finite memory structure is operated for temporarily uncertain continuous time system. That is, depending on the presence of uncertainty, one of infinite memory structure and finite memory structure filtered estimates is operated selectively to obtain the valid estimate. A couple of test variables and declaration rule are developed to detect uncertainty presence or uncertainty absence, to operate the suitable one from two kinds of filtered estimates, and to obtain ultimately the valid filtered estimate. Through computer simulations for a continuous time aircraft engine system with different measurement memory lengths and temporary model uncertainties, the proposed state estimation filtering algorithm can work well in temporarily uncertain as well as certain continuous time systems. Moreover, the proposed state estimation filtering algorithm shows remarkable superiority to the infinite memory structure filtering when temporary uncertainties occur in succession.

Validation, Measurement Uncertainty, and Determination of Bixin and Norbixin in Processed Foods of Animal Resources Distributed in Korea

  • Ga-Yeong Lee;Choong-In Yun;Juhee Cho;Young-Jun Kim
    • Food Science of Animal Resources
    • /
    • v.43 no.6
    • /
    • pp.949-960
    • /
    • 2023
  • This research aimed to validate a high-performance liquid chromatography method for the quantitative determination of bixin and norbixin in various foods. The Diode Array Detector (495 nm) technique was used. Method was validated for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy, and the measurement uncertainty was assessed. The calibration curve showed excellent linearity (r2≥0.9999) over the tested concentration range of 0.2-25 mg/L. The LOD and LOQ were 0.03-0.11 and 0.02-0.05 mg/L for bixin and norbixin, respectively. The intra-and inter-day accuracies and precisions were 88.0±1.3-97.0±0.5% and 0.2%-2.6% relative SD (RSD) for bixin and 88.2±0.8-105.8±0.8% and 0.3%-2.7% RSD for norbixin, respectively. Inter-laboratory validation for accuracy and precision was conducted in three laboratories, and these results all met the AOAC guidelines. In addition, the relative expanded uncertainty (<22%) satisfied the CODEX recommendation. Furthermore, products distributed in Korea were monitored for annatto extracts using the proposed method to demonstrate its application. The developed analytical method is reliable for quantifying bixin and norbixin in various foods.