• Title/Summary/Keyword: Unbonded tendons

Search Result 66, Processing Time 0.024 seconds

Relation of Deflection of Prestressed Concrete Members to Unbonded Tendon Stress and Effects of Various Parameters (비부착 프리스트레스트 보강재를 갖는 PSC 부재의 변위와 프리스트레스트 보강재 응력의 상관관계 및 변수별 효과)

  • 문정호;임재형;이창규
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.2
    • /
    • pp.171-179
    • /
    • 2002
  • This paper is a part of research series for the verification of the proposed Moon/Lim design equation. An analytical study was performed to examine the relation between the flexural behavior and the unbonded tendon stress of PSC members. The strain compatibility assumption was used in this study since previous studies showed that the stress variations of tendon had a close relation with the member displacements. The proposed equation has been developed with the same assumption of strain compatibility. Therefore the analytical procedure with the strain compatibility assumption was developed to compute the member displacements of previous tests. Then the analytical results were compared with tests results. The comparison showed that the strain compatibility assumption can be properly applicable to the design equation. Based on the analytical results, the relation between the tendon stress and the member flexural behavior at ultimate was examined. A parametric study also carried out with regard to the member displacements. As results, the parameters used for the proposed equation were proven to be proper for the computation of tendon stress.

Flexural Behavior Characteristics of Steel I-Beam Strengthened by the Post-tensioning Method on the Field Experiment (현장실험을 통한 외부 후긴장 Steel I-Beam의 휨 거동 특성)

  • Cho, Doo-Yong;Park, Dae-Yul;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.151-158
    • /
    • 2002
  • Recently, the externally prestressed unbonded steel I-beam bridges have been increasingly built. The mechanical behavior of prestressed steel I-beams which are with external unbonded tendon is different from that of normal bonded PSC beams in a point of that the slip of tendons at deviators and the change of tendon eccentricity occurs, when external loads are applied in external unbonded steel I-beams. The concept of prestressing steel structures has not been widely considered, in spite of long and successful history of prestressing concrete members. In this study, The field experiment on prestressed steel I-beams has been performed in the various aspects of prestressed I-beam including the tend on type and profile.

Flexural behavior of post-tensioned precast concrete girder at negative moment region

  • Choi, Seung-Ho;Heo, Inwook;Kim, Jae Hyun;Jeong, Hoseong;Lee, Jae-Yeon;Kim, Kang Su
    • Computers and Concrete
    • /
    • v.30 no.1
    • /
    • pp.75-83
    • /
    • 2022
  • This study introduced a post-tensioned precast concrete system that was developed and designed to improve the performance of joints by post-tensioning. Full-scaled specimens were tested to investigate flexural performances at the negative moment region, where the test variables were the presence of slabs, tendon types, and post-tensioned lengths. A specimen with slabs exhibited significantly higher stiffness and strength values than a specimen without slabs. Thus, it would be reasonable to consider the effects of a slab on the flexural strength for an economical design. A specimen with unbonded mono-tendons had slightly lower initial stiffness and flexural strength values than a specimen with bonded multi-tendons but showed greater flexural strength than the value specified in the design codes. The post-tensioned length was found to have no significant impact on the flexural behavior of the proposed post-tensioned precast concrete system. In addition, a finite element analysis was conducted on the proposed post-tensioned precast concrete system, and the tests and analysis results were compared in detail.

Experiment of Flexural Behavior of Prestressed Concrete Beams with External Tendons according to Tendon Area and Tendon Force (강선량 및 긴장력에 따른 외부 강선을 가진 PSC 보의 휨거동 실험)

  • Yoo, Sung-Won;Yang, In-Hwan;Suh, Jeong-In
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.513-521
    • /
    • 2009
  • Recently, the externally prestressed unbonded concrete structures are increasingly being built. The mechanical behavior of prestressed concrete beams with external unbonded tendon is different from that of normal bonded PSC beams in that the slip of tendons at deviators and the change of tendon eccentricity occurs as external loads are applied in external unbonded PSC beams. The purpose of the present paper is therefore to evaluate the flexural behavior by performing static flexural test according to tendon area and tendon force. From experimental results, before flexural cracking, there was no difference between external members and bonded members. However, after cracking, yielding load of reinforcement, ultimate load, and the tendon stress of external members was lower than that of bonded members. For the relationship of load-tendon stress, the increasing of tendon strain was inversely proportional to the initial tendon force. However, even if the initial tendon force was large, the tendon strain with small effective stress was smaller than that with large effective stress. The concrete compressive strain was proportional to the effective stress of external tendon. From the comparison between test results and codes, the ACI-318 could not consider the effect of tendon force or effective stress, and especially the results of ACI-318 were very small, so it was very conservative. And the AASHTO 1994 could be influenced on the tendon area, initial force and effective stress, but as it was made on the basis of internal unbonded tendon, its results were much larger than the test results. For this reason, the new correct predict equation of external tendon stress will be needed.

Seismic behavior of post-tensioned precast reinforced concrete beam-to-column connections

  • Cheng, Chin-Tung
    • Computers and Concrete
    • /
    • v.5 no.6
    • /
    • pp.525-544
    • /
    • 2008
  • In this research, the self-centering effect in precast and prestressed reinforced concrete structures was investigated experimentally. The reinforced concrete beams and columns were precast and connected by post-tensioning tendons passing through the center of the beams as well as the panel zone of the connections. Three beam-to-interior-column connections were constructed to investigate parameters such as beam to column interfaces (steel on steel or plastic on plastic), energy dissipating devices (unbonded buckling restrained steel bars or steel angles) and the spacing of hoops in the panel zone. In addition to the self-centering effect, the shear strength in the panel zone of interior column connections was experimentally and theoretically evaluated, since the panel zone designed by current code provisions may not be conservative enough to resist the panel shear increased by the post-tensioning force.

Strengthening of Reinforced Concrete Continuous Beams in Flexure by Partial External Unbonded Tendons (철근콘크리트 연속보에서 부분프리스트레스 도입에 의한 휨보강 효과)

  • Yun, Hyun-Do;Yang, Il-Seung;Lim, Jea-Hyung;Moon, Jeong-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.165-172
    • /
    • 2006
  • A variety of techniques for strengthening have been developed, including pate bonding, external prestressing and overslabbing. Expecially, a strengthening technique for reinforced concrete beams using external unbonded reinforcement offers advantages in speed and simplicity of installation. The purpose of this paper is to investigate the capabilities of a new retrofitting technique, namely external prestressing(out-cable), for flexural strengthening of beams. Results of 2 physical tests (external Post-tension and out-cable system specimen) on strengthened reinforced concrete continuous beams are reported and compared. It is shown that the out-cable system can provide strength enhancement.

The Structural Integrity Test for a PSC Containment with Unbonded Tendons and Numerical Analysis I (비부착텐던 PSC 격납건물에 대한 구조건전성시험 및 수치해석 I)

  • Noh, Sanghoon;Jung, Raeyoung;Kim, Sung-Taek;Lim, Sang-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.523-533
    • /
    • 2015
  • A reactor containment acts as a final barrier to prevent leakage of radioactive material due to the possible reactor accidents into external environment. Because of the functional importance of the containment building, the SIT(Structural Integrity Test) for containments shall be performed to evaluate the structural acceptability and demonstrate the quality of construction. An initial numerical analysis was performed to simulate the results obtained from the SIT for a prestressed concrete(PSC) structure. But the analysis results by the initial model expected smaller displacements than the measured ones by 30% at some locations. Accordingly, the research and development to improve the initial model to corelate the measured results of the SIT more properly have been performed. In this paper, the effects of the loss of concrete due to duct for tendons and the contact of duct and tendons in un-bonded tendon system are mainly evaluated based on the preliminary analysis results. In addition, the importances of the proper definition of mesh connectivity among structural elements of concrete, liner plates, rebars and tendons are discussed.

Ultimate Stress of Prestressing Steel in Prestressed Concrete Beams Strengthened by External Prestressing (외부 프리스트레싱으로 보강된 프리스트레스트 콘크리트 보에서 프리스트레싱 강재의 극한응력)

  • Park Sang-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.677-686
    • /
    • 2004
  • This study deals with literature review, developing a predicting equation for the ultimate stress of internal and external prestressing steel, and an experimental test with the parameters affecting the ultimate stress of prestressing steel in prestressed concrete beams strengthened by external prestressing tendons. The proposed predicting equation takes rationally the effect of internal and external prestressing steels into consideration as a function of prestressing steel depth to neutral depth ratio. In the experimental study, prestressed concrete beams strengthened using external steel tendons are tested with the test parameters having a large effect on the ultimate stress of internal and external prestressing steel. The test parameters include internal and external prestressing steel reinforcement ratio and span to depth ratio. The test results are analyzed to confirm the rationality and applicability of the proposed equation for predicting the ultimate stress of internal and external prestressing steel. This research shows that the results obtained by the proposed equation for predicting the ultimate stress agreed very well with the test results.

A finite element analysis for unbonded flexible risers under bending loads

  • Xiqia, Chen;Shixiao, Fu;Yun, Gao;Xiaying, Du
    • Ocean Systems Engineering
    • /
    • v.5 no.2
    • /
    • pp.77-89
    • /
    • 2015
  • As the exploitation of oil and gas resources advances into deeper waters and harsher environments, the design and analysis of the flexible risers has become the research focus in the offshore engineering filed. Due to the complexity of the components and the sliding between the adjacent layers, the bending response of the flexible risers is highly non-linear. This paper presents the finite element analysis of the flexible risers under bending loads. The detailed finite element model of the flexible riser is established in ABAQUS software. This finite element model incorporates all the fine details of the riser to accurately predict its nonlinear structural behavior. Based on the finite element model, the bending moment-curvature relationships of a flexible riser under various axisymmetric loads have been investigated. The results have been compared with the analytical ones obtained from the literature and good agreements have been found. Moreover, the stress of the tendon armors has been studied. The non-linear relationship between the armor tendons' stress and the bending loads has been obtained.

Data-driven SIRMs-connected FIS for prediction of external tendon stress

  • Lau, See Hung;Ng, Chee Khoon;Tay, Kai Meng
    • Computers and Concrete
    • /
    • v.15 no.1
    • /
    • pp.55-71
    • /
    • 2015
  • This paper presents a novel harmony search (HS)-based data-driven single input rule modules (SIRMs)-connected fuzzy inference system (FIS) for the prediction of stress in externally prestressed tendon. The proposed method attempts to extract causal relationship of a system from an input-output pairs of data even without knowing the complete physical knowledge of the system. The monotonicity property is then exploited as an additional qualitative information to obtain a meaningful SIRMs-connected FIS model. This method is then validated using results from test data of the literature. Several parameters, such as initial tendon depth to beam ratio; deviators spacing to the initial tendon depth ratio; and distance of a concentrated load from the nearest support to the effective beam span are considered. A computer simulation for estimating the stress increase in externally prestressed tendon, ${\Delta}f_{ps}$, is then reported. The contributions of this paper is two folds; (i) it contributes towards a new monotonicity-preserving data-driven FIS model in fuzzy modeling and (ii) it provides a novel solution for estimating the ${\Delta}f_{ps}$ even without a complete physical knowledge of unbonded tendons.