• Title/Summary/Keyword: Unbonded Prestressing

Search Result 53, Processing Time 0.021 seconds

Flexural Behavior of External Prestressed H-Beam (외부 긴장된 H형 보의 휨거동 특성)

  • Yang, Dong Suk;Lim, Sang Hun;Park, Sun Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.1
    • /
    • pp.79-85
    • /
    • 2002
  • Recently, prestressed H-Beam bridges with external unbonded Tendons are increasingly built. The mechanical behavior of prestressed steel H-beams is different from that of normal bonded PSC beams in a point of the slip of tendons at deviators and the change of tendon eccentricity that occurs, when service load are applied in external unbonded steel H-beams. The concept of prestressing steel structures has been widely considered, in spite of long and successful history of prestressing concrete members. In the study, The flexural test on prestressed steel H-beams has been performed in the various aspects of prestressed H-beam including the tendon type and profile. The load was plotted against the deflection and the strain respectively in the steel beam and prestressing bars. The value expected with the equation of internal force equilibrium and compatibility between the deflection of the bars and the H-beam was found to correlate well with the measured data.

Out-of-plane behavior of perforated masonry walls strengthened with steel-bar truss system

  • Hwang, Seung-Hyeon;Mun, Ju-Hyun;Yang, Keun-Hyeok;Kim, Sanghee
    • Structural Engineering and Mechanics
    • /
    • v.83 no.6
    • /
    • pp.799-810
    • /
    • 2022
  • This study investigated the effect of the strengthening efficiency of unbonded steel-bar truss system on the out-of-plane behavior of perforated masonry walls. Four full-scale unreinforced masonry (URM) walls with two different planes were prepared using the unbonded steel-bar truss system and a URM walls without strengthening. All masonry walls were tested under constant axial and cyclic lateral loads. The obtained test results indicated that the pinching effect in the out-plane behavior of masonry walls tends to decrease in the in- and out-of-plane strengthened URM walls using the unbonded steel-bar truss system with the higher prestressing force ratio (Rp) of vertical reinforcing bars in the unbonded steel-bar truss system, regardless of the perforated type of the masonry wall. Consequently, the highest maximum shear resistance and cumulative dissipated energy at peak load in the post-peak behavior were observed in the in- and out-plane strengthened URM walls with the highest Rp values, which are 2.7 and 6.0 times higher than those of URM. In particular, the strengthening efficiency of the unbonded steel-bar truss system was primarily attributed to the vertical prestressed steel-bars rather than the diagonal steel-bars, which indicates that the strains in the vertical prestressed steel-bars at the peak load were approximately 1.6 times higher than those in the diagonal steel-bars.

The Effect of Mild Tensile Reinforcement and Effective Prestress on the Flexural Performance of the Prestressed Lightweight Concrete Beams with Unbonded Tendons (비부착 프리스트레스트 경량 콘크리트 보의 휨 거동에 대한 부착 철근과 유효 프리스트레스의 영향)

  • Mun, Ju-Hyun;Yang, Keun-Hyeok;Byun, Hang-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.617-626
    • /
    • 2011
  • Seven post-tensioned lightweight concrete (LWC) beam specimens were tested under a symmetrical two-point top loading system. The parameters investigated were the amounts of mild longitudinal reinforcement and effective prestressing. The design compressive strength and dry density of the LWC tested were 30 MPa and 1,770 $kg/m^3$, respectively. Similar to post-tensioned normal weight concrete (NWC) beams, the crack propagation and stress increase of the unbonded tendons were significantly affected by the amounts of mild longitudinal reinforcement and effective prestressing. With the increase in the amounts of mild longitudinal reinforcement and effective prestressing, the serviceability and flexural capacity of the beams were enhanced whereas the stress increase in the unbonded tendons decreased. To control the crack width in post-tensioned LWC beams, a minimum amount of mild longitudinal reinforcement specified in ACI 318-08 provision is required. The flexural behavior of post-tensioned LWC beams and stress increase of the unbonded tendons could be rationally predicted by the proposed non-linear two-dimensional analysis. On the other hand, ACI 318-08 flexure provision was too conservative about the post-tensioned LWC beams.

The Analysis for Reinforced Concrete Beams Strengthened with Externally Unbonded Prestressed CFRP Plates (비부착 탄소섬유판 긴장재로 외부 긴장 보강된 철근콘크리트 보의 해석)

  • Park, Jong Sup;Jung, Woo Tai;Park, Young Hwan;Kim, Chul Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.439-445
    • /
    • 2008
  • This paper suggests a modified bond reduction coefficient considering the average CFRP (Carbon Fiber Reinforced Polymer) strain concept for the unbonded prestressed CFRP plate strengthening system. The strengthened length and the pure bending length were seen to influence the variation of the strain of unbonded CFRP plate. Therefore, a new bond reduction coefficient considering such effect was suggested. Comparison with the experimental data revealed that the analytic results obtained by considering the proposed bond reduction coefficient were effective in estimating the strain of the unbonded CFRP plate in the CFRP plate prestressing system.

Ultimate Stress of Prestressing CFRP Tendons in PSC Beams Strengthened by External CFRP Prestressing (외부 CFRP 프리스트레싱으로 보강된 PSC 보에서 CFRP 텐던의 극한응력)

  • Park, Sang-Yeol;Kim, Chang-Hoon;Hong, Seong-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.735-744
    • /
    • 2007
  • This study deals with literature review, developing a predicting equation for the ultimate stress of prestressing (PS) CFRP, and experimental test with the parameters affecting the ultimate stress of prestressing CFRF in prestressed concrete beams strengthened by external prestressing. The ACI (American Concrete Institute) predicting equation for the ultimate stress of unbonded prestressing CFRP is analyzed to develop a new integrated predicting equation. The proposed predicting equation takes rationally the effect of internal PS steel into consideration as a function of prestressing tendon depth to neutral depth ratio. In the experimental study, prestressed concrete beams strengthened using external prestressing CFRP are tested with the test parameters having a large effect on the ultimate stress of prestressing CFRP. The test parameters includes infernal prestressing steel and external prestressing CFRP tendon reinforcement ratios, and span to depth ratio. The test results are analyzed to confirm the rationality and applicability of the proposed equation for predicting the ultimate stress of external prestressing CFRP.

Ultimate Stress of Prestressing Steel in Prestressed Concrete Beams Strengthened by External Prestressing (외부 프리스트레싱으로 보강된 프리스트레스트 콘크리트 보에서 프리스트레싱 강재의 극한응력)

  • Park Sang-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.677-686
    • /
    • 2004
  • This study deals with literature review, developing a predicting equation for the ultimate stress of internal and external prestressing steel, and an experimental test with the parameters affecting the ultimate stress of prestressing steel in prestressed concrete beams strengthened by external prestressing tendons. The proposed predicting equation takes rationally the effect of internal and external prestressing steels into consideration as a function of prestressing steel depth to neutral depth ratio. In the experimental study, prestressed concrete beams strengthened using external steel tendons are tested with the test parameters having a large effect on the ultimate stress of internal and external prestressing steel. The test parameters include internal and external prestressing steel reinforcement ratio and span to depth ratio. The test results are analyzed to confirm the rationality and applicability of the proposed equation for predicting the ultimate stress of internal and external prestressing steel. This research shows that the results obtained by the proposed equation for predicting the ultimate stress agreed very well with the test results.

Seismic performance of prefabricated bridge columns with combination of continuous mild reinforcements and partially unbonded tendons

  • Koem, Chandara;Shim, Chang-Su;Park, Sung-Jun
    • Smart Structures and Systems
    • /
    • v.17 no.4
    • /
    • pp.541-557
    • /
    • 2016
  • Prefabricated bridge substructures provide new possibility for designers in terms of efficiency of creativity, fast construction, geometry control and cost. Even though prefabricated bridge columns are widely adopted as a substructure system in the bridge construction project recently, lack of deeper understanding of the seismic behavior of prefabricated bridge substructures cause much concern on their performance in high seismic zones. In this paper, experimental research works are presented to verify enhanced design concepts of prefabricated bridge piers. Integration of precast segments was done with continuity of axial prestressing tendons and mild reinforcing bars throughout the construction joints. Cyclic tests were conducted to investigate the effects of the design parameters on seismic performance. An analytical method for moment-curvature analysis of prefabricated bridge columns is conducted in this study. The method is validated through comparison with experimental results and the fiber model analysis. A parametric study is conducted to observe the seismic behavior of prefabricated bridge columns using the analytical study based on strain compatibility method. The effects of continuity of axial steel and tendon, and initial prestressing level on the load-displacement response characteristics, i.e., the strain of axial mild steels and posttensioned tendon at fracture and concrete crushing strain at the extreme compression fiber are investigated. The analytical study shows the layout of axial mild steels and posttensioned tendons in this experiment is the optimized arrangement for seismic performance.

Flexural Behavior Characteristics of Steel I-Beam Strengthened by the Post-tensioning Method on the Field Experiment (현장실험을 통한 외부 후긴장 Steel I-Beam의 휨 거동 특성)

  • Cho, Doo-Yong;Park, Dae-Yul;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.151-158
    • /
    • 2002
  • Recently, the externally prestressed unbonded steel I-beam bridges have been increasingly built. The mechanical behavior of prestressed steel I-beams which are with external unbonded tendon is different from that of normal bonded PSC beams in a point of that the slip of tendons at deviators and the change of tendon eccentricity occurs, when external loads are applied in external unbonded steel I-beams. The concept of prestressing steel structures has not been widely considered, in spite of long and successful history of prestressing concrete members. In this study, The field experiment on prestressed steel I-beams has been performed in the various aspects of prestressed I-beam including the tend on type and profile.

Load and Deflection Recovery Capacities of PSC Girder with Unbonded PS H-Type Steel

  • Kim, Jong Wook;Kim, Jang-Ho Jay;Kim, Tae-Kyun;Lee, Tae Hee;Yang, Dal Hun
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1336-1349
    • /
    • 2018
  • Generally, a precast prestressed concrete (PSC) beam is used as girders for short-to-medium span (less than 30 m) bridges due to the advantages of simple design and construction, reduction of construction budget, maintenance convenience. In order to increase the span length beyond 50 m of precast PSC girder, PSC hollow box girder with unbonded prestressed H-type steel beam placed at the compressive region is proposed. The unbonded compressive prestressing in the H-type steel beams in the girder is made to recover plastic deflection of PSC girder when the pre-stressing is released. Also, the H-steel beams allow minimization of depth-to-length ratio of the girder by reducing the compressive region of the cross-section, thereby reducing the weight of the girder. A quasi-static 3-point bending test with 4 different loading steps is performed to verify safety and plastic deflection recovery of the girder. The experimental results showed that the maximum applied load exceeded the maximum design load and most of the plastic deflection was recovered when the compressive prestressing of H-type steel beams is released. Also using prestressed H-type steel as compression reinforcements in the upper part of cross section, repair and restoration difficulty and cost of PSC girders should be significantly reduced. The study result and analysis are discussed in detail in the paper.

Strengthening of Reinforced Concrete Continuous Beams in Flexure by Partial External Unbonded Tendons (철근콘크리트 연속보에서 부분프리스트레스 도입에 의한 휨보강 효과)

  • Yun, Hyun-Do;Yang, Il-Seung;Lim, Jea-Hyung;Moon, Jeong-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.165-172
    • /
    • 2006
  • A variety of techniques for strengthening have been developed, including pate bonding, external prestressing and overslabbing. Expecially, a strengthening technique for reinforced concrete beams using external unbonded reinforcement offers advantages in speed and simplicity of installation. The purpose of this paper is to investigate the capabilities of a new retrofitting technique, namely external prestressing(out-cable), for flexural strengthening of beams. Results of 2 physical tests (external Post-tension and out-cable system specimen) on strengthened reinforced concrete continuous beams are reported and compared. It is shown that the out-cable system can provide strength enhancement.