• Title/Summary/Keyword: Unbonded

Search Result 210, Processing Time 0.025 seconds

Flexural ductility of prestressed concrete beams with unbonded tendons

  • Au, F.T.K.;Chan, K.H.E.;Kwan, A.K.H.;Du, J.S.
    • Computers and Concrete
    • /
    • v.6 no.6
    • /
    • pp.451-472
    • /
    • 2009
  • Based on a numerical method to analyse the full-range behaviour of prestressed concrete beams with unbonded tendons, parametric studies are carried out to investigate the influence of 11 parameters on the curvature ductility of unbonded prestressed concrete (UPC) beams. It is found that, among various parameters studied, the depth to prestressing tendons, depth to non-prestressed tension steel, partial prestressing ratio, yield strength of non-prestressed tension steel and concrete compressive strength have substantial effects on the curvature ductility. Although the curvature ductility of UPC beams is affected by a large number of factors, rather simple equations can be formulated for reasonably accurate estimation of curvature ductility. Conversion factors are introduced to cope with the difference in partial safety factors, shapes of equivalent stress blocks and the equations to predict the ultimate tendon stress in BS8110, EC2 and ACI318. The same equations can also be used to provide conservative estimates of ductility of UPC beams with compression steel.

An Improved Analysis Model for the Ultimate Behavior of Unbonded Prestressed Concrete

  • Cho, Taejun;Kim, Myeong-Han
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.4
    • /
    • pp.149-157
    • /
    • 2017
  • An innovative analysis method is proposed in this paper for the determination of ultimate resistance of prestressed concrete beams. The proposed method can be applied to simply supported or continuous beams in a unified manner whether structure and external loads are symmetric or not. Through the iterative nonlinear strain compatibility solutions, this method can also be applied to the non-prismatic section/un-symmetrical composite structures under moving load. The conventional studies have used the failure criteria when the strain of concrete reaches 0.003. However compared with bonded case, the value of strain in the reinforcement is much smaller than bonded case, thus, unbonded prestressed cases show compressive failure mode. It is shown that the proposed method gives acceptable results within 5% error compared with the prior experimental results. It can be shown that the proposed method can reach the solution much faster than typical three-dimensional finite element analysis for the same problem. This method is applicable to the existing unbonded prestressed members where deterioration has occurred leading to the reduced ultimate resistance or safety. In all, the proposed procedure can be applied to the design and analysis of newly constructed structures, as well as the risk assessment of rehabilitated structures.

Determination of Steel-Concrete Interface Parameters : Bonded and Unbonded Slip Tests (강-콘크리트 계면의 계면상수 결정 : 부착 및 비부착 슬립실험)

  • Lee, Ta;Joo, Young-Tae;Lee, Yong-Hak
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.773-780
    • /
    • 2009
  • Experiments on steel-concrete interface are performed to investigate and determine the mechanical roles and properties of interface parameters. The intrinsic different nature of bonded and unbonded interfaces are addressed based on the experimental observations that were obtained from two types of tests considering bonded and unbonded interfaces. The unbonded tests are performed for the specimens that are in unbonded when the initially bonded specimens are tested first. Four cases of lateral confinements including pure slip, and low and medium levels of lateral pressure are taken into account to investigate the effects of lateral confinements on interface behavior. It is shown that the maximum shear strengths, the levels of residual strengths and the Mode II fracture energy release rates are linearly related to the confinement levels. Based on the experimental evidences obtained from this study, the values of interface parameters required in a steel-concrete interface constitutive model will be presented in the companion paper.

Ultimate Analysis of RC Beam with Unbonded Prestressing CFRP Plate (비부착 CFRP 판으로 긴장된 RC 보의 극한해석)

  • Lee, Jae-Seok;Choi, Kyu-Chon;Park, Young-Ha
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.249-252
    • /
    • 2008
  • A study for the nonlinear analysis method of RC(Reinforced Concrete) beams with unbonded prestressing CFRP plate is presented. The cross-section of RC beam element is idealized as an assemblage of concrete and reinforcing steel fibers in order to account for varied material properties within the cross-section of the element. The unbonded CFRP plate is modeled as a series of the CFRP plate segments each of which is linked to the RC beam element, but slips without any resistance to simulate the unbonded behavior of the CFRP plate. The stress of each CFRP plate segment is redistributed iteratively using the force equilibrium relationship at each common node until it reaches at the same stress level. To evaluate the validity of the proposed analysis method, the results of ultimate analysis of the reinforced concrete beams with unbonded prestressing CFRP plates are compared with the experimental results obtained from other investigators. The proposed analysis method is found to predict ultimate behaviors of these beams fairly well.

  • PDF

Seismic Behavior of RC Beam-Column Exterior Joints with Unbonded Tendons and High Strength Concrete (비부착 강연선과 고강도 콘크리트를 적용한 철근콘크리트 외부 접합부의 내진 거동)

  • Kwon, Byung Un;Kang, Thomas H.-K.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.283-292
    • /
    • 2015
  • In the moment frame subjected to earthquake loads, beam-column joint is structurally important for ductile behavior of a system. ACI Committee 352 proposed guidelines for designing beam-column joint details. The guidelines, however, need to be updated because of the lack of data regarding several factors that may improve the performance of joints. The purpose of this study is to investigate the seismic performance of reinforced concrete exterior joints with high-strength materials and unbonded tendons. Three specimens with different joint shear demand-to-strength ratios were constructed and tested, where headed bars were used to anchor the beam bars into the joint. All specimens showed satisfactory seismic behavior including moment strength of 1.3 times the nominal moment, ductile performance (ductility factor = at least 2.4), and sufficiently large dissipated energy.

Effect of prestressing on the first flexural natural frequency of beams

  • Jaiswal, O.R.
    • Structural Engineering and Mechanics
    • /
    • v.28 no.5
    • /
    • pp.515-524
    • /
    • 2008
  • In this paper the effect of prestressing force on the first flexural natural frequency of beams is studied. Finite element technique is used to model the beam-tendon system, and the prestressing force is applied in the form of initial tension in the tendon. It is shown that the effect of prestressing force on the first natural frequency depends on bonded and unbonded nature of the tendon, and also on the eccentricity of tendon. For the beams with bonded tendon, the prestressing force does not have any appreciable effect on the first flexural natural frequency. However, for the beams with unbonded tendon, the first natural frequency significantly changes with the prestressing force and eccentricity of the tendon. If the eccentricity of tendon is small, then the first natural frequency decreases with the prestressing force and if the eccentricity is large, then the first flexural natural frequency increases with the prestressing force. Results of the present study clearly indicate that the first natural frequency can not be used as an easy indicator for detecting the loss of prestressing force, as has been attempted in some of the past studies.

Flexural behavior of RC beams with unbonded prestressing CFRP laminates (비부착 탄소섬유판 긴장재를 갖는 철근 콘크리트 보의 휨거동)

  • Park, Jong-Sup;Park, Young-Hwan;Jung, Woo-Tai
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.258-261
    • /
    • 2006
  • This study investigates the flexural behavior and strengthening performance of RC beams with unbonded prestressing CFRP laminates through static bending tests. The aluminum anchorage system has been developed in tins study and successfully applied to the test specimens. The prestressing level of CFRP laminatehas was 0 %, 20 %, 30% and 50 % of its tensile strength. Experimental results revealed that RC beams with unbonded prestressing CFRP laminates showed increased crack load and yield load according to the level of prestress. It has also been observed that the length of the CFRP laminates does not have significant effect on the maximum load.

  • PDF

Design and Construction of Flat Slab using Unbonded Post-tension System (비부착 포스트텐션 플랫 슬래브의 설계와 시공)

  • Chung, Kwang-Ryang;Park, Jung-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.91-96
    • /
    • 2011
  • The flat slab is well-known as a structural system to reduce the story height, so it is broadly used for recent building. However, the normal RC flat slab is not appropriate for the long span, and the quantity of reinforcement bar and concrete is raised. Recently, the post-tensioning system has been introduced and used widely as an alternative method. Nevertheless, in Korea, it is not used broadly due to lack of the understanding and field experience. Especially, the post-tensioning system is hesitated to use due to uncertainty of construction ability and economics. This paper will introduce applicability to site and economics of unbonded post-tensioning system through construction examples.

  • PDF

Use of Unbonded Caps in Determination of Compressive Strength of Hardened Concrete Cylinders (콘크리트 원주형 공시체의 압축강도 시험을 위한 Unbonded Cap의 사용)

  • 심재원;안태송
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.161-166
    • /
    • 2000
  • To save efforts for capping in the compressive strength tests of concrete, unbonded capping system has been standardized by ASTM C 1231 and AS 1012.9, respectively. These standards, however, do not sufficiently give a full detail of accessories such as steel retaining cap and rubber pad, especially hardness of rubber. Hence, without testing for sizes of steel retaining cap and rubber pad, tests for the quality control of rubber pads were conducted in detail according to Japanese studies. Based on tests, the range of hardness for rubber pad by the compressive strength(200~ 400kgf/$\textrm{cm}^2$) of concrete has been proposed and the guideline of reuses of a rubber pad is described.

  • PDF

Effect of the Reinforcement Index on the Unbonded Tendon Stress of Post-tensioned Lightweight Concrete Beams (포스트텐션 경량콘크리트 보의 비부착 긴장재 응력에 대한 보강지수의 영향)

  • Mun, Ju-Hyun;Yang, Keun-Hyeok;Byun, Hang-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.89-90
    • /
    • 2010
  • Three post-tensioned lightweight concrete beams were tested to examine the effect of the reinforcement index on the unbonded tendon stress at ultimate strength of the beams. The reinforcement index selected for main variables were 0.06, 0.15, 0.30. Test results showed that the stress of the unbonded tendons in the ultimate strength of the post-tensioned lightweight concrete beams can be conservatively evaluated using the empirical equations specified in ACI 318-08.

  • PDF