• Title/Summary/Keyword: Unbalanced Output

Search Result 97, Processing Time 0.026 seconds

Comparison of Voltage Unbalance Factor for Line and Phase Voltage (선간전압과 상전압에 대한 전압불평형율의 비교)

  • Kim Jong-Gyeum;Park Young-Jeen;Lee Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.9
    • /
    • pp.403-407
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, voltage unbalance is generated at the user's 3-phase 4-wire distribution systems with single & three phase. Voltage unbalance is mainly affected by load system rather than power system. Unbalanced voltage will draws a highly unbalanced current and results in the temperature rise and the low output characteristics at the machine. It is necessary to analyse correct voltage unbalance factor for reduction of side effects in the industrial sites. Voltage unbalance is usually defined by the maximum percent deviation of voltages from their average value, by the method of symmetric components or by the expression in a more user-friendly form which requires only the three line voltage readings. If the neutral point is moved by the unbalanced load at the 3-phase 4-wire system. Line and phase voltage unbalance leads to different results due to zero-sequence component. So that it is difficult to analyse voltage unbalance factor by the conventional analytical method, This paper presents a new analytical method for phase and line voltage unbalance factor in 4-wire systems. Two methods indicate exact results.

A Simplified Modulation Strategy for Three-leg Voltage Source Inverter Fed Unsymmetrical Two-winding Induction Motor

  • Sinthusonthishat, Saliltip;Chuladaycha, Nontawat
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1337-1344
    • /
    • 2013
  • This paper presents a simplified modulation strategy for the three-leg VSI fed two-winding induction motor. The strategy provides independent unbalanced voltage control for the main and auxiliary windings. This make the motor can be reversed rotation through the range of motor speed operation without limitation of voltage boost of the auxiliary winding. To study the advantages of the proposed drive, the experimental results such as voltage stresses, hysteresis band of the currents in locus, and also acoustic noise levels of the three-leg VSI are compared with those of the conventional two-leg topology. The results obviously show that the proposed technique achieves superior performance compared with the traditional scheme in case of dramatic increase of DC bus utilization, effective reduction of harmonic voltages content, and also significant enhancement of motor efficiency.

Compensation of Current Offset Error in Half-Bridge PWM Inverter for Linear Compressor

  • Kim, Dong-Youn;Im, Won-Sang;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1593-1600
    • /
    • 2015
  • This paper proposes a novel compensation algorithm of current offset error for single-phase linear compressor in home appliances. In a half-bridge inverter, current offset error may cause unbalanced DC-link voltage when the DC-link is comprised of two serially connected capacitors. To compensate the current measurement error, the synchronous reference frame transformation is used for detecting the measurement error. When an offset error occurs in the output current of the half-bridge inverter, the d-axis current has a ripple with frequency equal to the fundamental frequency. With the use of a proportional-resonant controller, the ripple component can be removed, and offset error can be compensated. The proposed compensation method can easily be implemented without much computation and additional hardware circuit. The validity of the proposed algorithm is verified through experimental results.

Calculation of Current Unbalance Factor for Induction Motor under the Unbalanced Voltages (불평형 전압 인가시 유도전동기 전류 불평형율 계산)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Eee, Eun-Woong;Jeong, Jong-Ho;Cho, Hyun-Gil;Lee, Jong-Hwan;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.633-634
    • /
    • 2006
  • The current unbalance occurs in an induction motor with the supply of unbalanced voltage. Existence of an current unbalance occurs by various problems at the time of driving by in crease of the noise not to mention output decrease of a motor by increase of a loss. We confirmed how current unbalance occurred by a voltage unbalance because a slip came to change by the driving situation of a subordinate as for the induction motor. We confirmed that case to run to a low slip in a ratio of the same voltage unbalance rate brought a high current unbalance rate.

  • PDF

State monitoring of inverter using auxiliary circuit (보조회로에 의한 인버터 상태 감시)

  • Baek, J.W.;Lee, B.K.;Kim, T.J.;Choi, Y.G.;Kim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1099-1101
    • /
    • 2003
  • The diagnosis of power converter using auxiliary circuit connected to output terminal is proposed and verified by experimental results in this paper. On contrary to conventional diagnosis method, the proposed monitoring technique is possible to measure the state of power converter and unbalanced output caused by a misfiring of switch and unusual control signal. Conventional method gives a monitoring approaches for only a unusual operation of power converter. In this paper, three signals with auxiliary circuit are obtained and analyzed to see the state of electrolytic capacitor, power semiconductor switches and output voltage balance. 2kVA inverter is made and fisted to verify the proposed circuit.

  • PDF

Modeling and Analysis of Sangmyeong Wind Farm with HESS (HESS가 연계된 상명풍력발전단지의 모델링과 해석)

  • Shin, Hyun;Kim, Eel-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.422-423
    • /
    • 2019
  • In accordance with the Carbon-Free Island by 2030 policy of Jeju Special Self-Governing Province, renewable energy sources are increasing in Jejudo Island. Due to the intermittent output characteristics of wind turbines, one of the renewable energy sources, which can cause unbalanced system conditions between the demand load and the power generation of Jejudo Island. The Korea Power Exchange limits the output of wind turbines for stabilizing the Jeju power system. Therefore, this paper proposes a method to supply a limited output of Sangmyeong Wind Farm in Jeju Power system to Energy Storage System(ESS) and Water Electrolysis Device(WED). The voltage and frequency fluctuation of the Jeju power system is checked accordingly. The simulation results are performed using the PSCAD/EMTDC program.

  • PDF

Rectifier with Comparator Using Unbalanced Body Biasing to Control Comparing Time for Wireless Power Transfer (비대칭 몸체 바이어싱 비교기를 사용하여 비교시간을 조절하는 무선 전력 전송용 정류기)

  • Ha, Byeong Wan;Cho, Choon Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1091-1097
    • /
    • 2013
  • This paper presents a rectifier with comparator using unbalanced body biasing in $0.11{\mu}m$ RF CMOS process. It is composed of MOSFETs and two comparators. The comparator is used to reduce reverse leakage current which occurs when the load voltage is higher than input voltage. For the comparator, unbalanced body biasing is devised. By using unbalanced body biasing, reference voltage for comparator changing from high state to low state is increased, and it reduces time interval for leakage current to flow. 13.56 MHz 2 Vpp signal is used for input and $1k{\Omega}$ resistor and 1 nF capacitor are used for output load for simulation and experimental environment. In simulation environment, voltage conversion efficiency(VCE) is 87.5 % and Power conversion efficiency(PCE) is 50 %. When the rectifier is measured, VCE shows 90.203 % and PCE shows 45 %.

Advanced Synchronous Reference Frame Controller for three-Phase UPS Powering Unbalanced and Nonlinear Loads (3상 무정전 전원장치에 적합한 새로운 구조의 동기좌표계 전압제어기)

  • Hyun Dong-Seok;Kim Kyung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.508-517
    • /
    • 2005
  • This paper describes a high performance voltage controller for 3-phase 4-wire UPS (Uninterruptible Power Supply) system, and proposes a new scheme of synchronous reference frame controller in order to compensate for the voltage distortions due to unbalanced and nonlinear loads. Proposed scheme can eliminate the negative sequence voltage component due to unbalanced loads and also reduce the harmonic voltage component due to non-linear loads, even when the bandwidth of voltage control loop is a very low. In order to compensate for the effects of unbalanced loads, the synchronous reference frame controller with the positive and negative sequence computation block is proposed, and the synchronous frame controller with a bandpass filter is proposed to compensate for the selected harmonic frequency of output voltage. The effectiveness of the proposed scheme has been investigated and verified through computer simulations and experiments by a 30kVA UPS.

Design of Odd Harmonic Repetitive Controller for Uninterruptible Power Supply (무정전 전원장치를 위한 홀수고조파 반복제어기의 설계)

  • Yoon, Chun-gi;Cho, Younghoon;Lim, Seung-beom
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.147-148
    • /
    • 2015
  • This paper presents an odd harmonic repetitive controller for single-phase UPS inverters. The proposed repetitive controller achieves the low output voltage THD and reduces the steady-state error by eliminating odd harmonic distortions caused by nonlinear and unbalanced loads. The proposed control scheme is verified through experiment using a 5kW single-phase T-type inverter.

  • PDF

Analysis on Output Efficiency of Chinese Listed Port Companies Based on DEA Model

  • XU, Yan;KIM, Hyung-Ho
    • East Asian Journal of Business Economics (EAJBE)
    • /
    • v.9 no.1
    • /
    • pp.41-51
    • /
    • 2021
  • Purpose - The purpose of this study is to propose strategies of improving efficiency of 20 listed port companies in China based on analysis of their input-output indexes from 2014 to 2018. Research design, data, and methodology - In this paper, the relevant input-output indicators of 20 listed port companies in China from 2014 to 2018 were adopted. Data derived from the company annual reports announced by Shanghai stock exchange and Shenzhen stock exchange. Comprehensive efficiency and pure technical efficiency were measured from output perspective by DEA and Malmquist index, and efficiency changes and regional efficiency were analyzed. Result - The results showed that the efficiency value of 20 listed port companies in China fluctuated and increased during 2014-2018, regional efficiency was unbalanced, and change of MPI was influenced by internal factors and external factors. Listed port companies affected by internal and external factors needed to make appropriate response to internal and external factors. Conclusion - The research conclusion can provide important reference information about management and planning for port companies in China and related areas. However, this paper is limited to the availability of data. So the improvement scheme for listed companies in inefficient regional ports needs further study, such as using AHP method.