• 제목/요약/키워드: Unbalanced Output

검색결과 98건 처리시간 0.024초

Low Frequency Current Ripple Mitigation of Two Stage Three-Phase PEMFC Generation Systems

  • Deng, Huiwen;Li, Qi;Liu, Zhixiang;Li, Lun;Chen, Weirong
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2243-2257
    • /
    • 2016
  • This paper presents a two stage three-phase proton exchange membrane fuel cell (PEMFC) generation system. When the system is connected to a three-phase load, it is very sensitive to the characteristics and type of the load. Especially unbalanced three-phase loads, which result in a pulsating power that is twice the output frequency at the inverter output, and cause the dc-link to generate low frequency ripples. This penetrates to the fuel cell side through the front-end dc-dc converter, which makes the fuel cell work in an unsafe condition and degrades its lifespan. In this paper, the generation and propagation mechanism of low frequency ripple is analyzed and its impact on fuel cells is presented based on the PEMFC output characteristics model. Then a novel method to evaluate low frequency current ripple control capability is investigated. Moreover, a control scheme with bandpass filter inserted into the current feed-forward path, and ripple duty ratio compensation based on current mode control with notch filter is also proposed to achieve low frequency ripple suppression and dynamic characteristics improvement during load transients. Finally, different control methods are verified and compared by simulation and experimental results.

Double Line Voltage Synthesis Strategy for Three-to-Five Phase Direct Matrix Converters

  • Wang, Rutian;Zhao, Yanfeng;Mu, Xingjun;Wang, Weiquan
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.81-91
    • /
    • 2018
  • This paper proposes a double line voltage synthesis (DLVS) strategy for three-to-five phase direct matrix converters. In the proposed strategy, the input and expected output voltages are divided into 6 segments and 10 segments, respectively. In addition, in order to obtain the maximum voltage transfer ratio (VTR), the input line voltages and "source key" should be selected reasonably according to different combinations of input and output segments. Then, the corresponding duty ratios are calculated to determine the switch sequences in different segment combinations. The output voltages and currents are still sinusoidal and symmetrical with little lower order harmonics under unbalanced or distorted input voltages by using this strategy. In addition, the common mode voltage (CMV) can be suppressed by rearranging some of the switching states. This strategy is analyzed and studied by a simulation model established in MATLAB/Simulink and an experimental platform, which is controlled by a DSP and FPGA. Simulation and experimental results verify the feasibility and validity of the proposed DLVS strategy.

불평형 전압으로 운전시 비선형 부하에 나타나는 현상 (The Phenomena Giving Rise of Nonlinear Load Operated by Unbalance Voltage)

  • 김종겸;이은웅
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권6호
    • /
    • pp.285-291
    • /
    • 2002
  • In general, utility voltage is maintained at a relatively low level of Phase unbalance since a low level of unbalance can cause a significant power supply ripple and heating effects on the power system equipment. Voltage unbalance more commonly emerges in individual customer loads due to phase load unbalanced, especially where single phase power loads are used. Under unbalanced input voltages large lower order harmonics appears at the input and output ports of Power conversion devices. As the application of adjustable -speed drives (ASDs) and their integration with complex industrial processes increase, so does the need to understand how ASDs perform during voltage This paper describes a real load test to investigate the performance of 3-HP adjustable speed drives by an unbalanced voltage at the low-voltage system.

병렬입력/직렬출력(PISO) 부스트 컨버터의 출력 전압 밸런싱 특성 해석 (Analysis of Parallel-Input Series-Output(PISO) Boost Converter With Output Voltage Balancing Characteristic)

  • 남현택;차헌녕;김흥근
    • 전력전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.40-46
    • /
    • 2018
  • In this study, the output voltage balancing characteristics of parallel-input series-output (PISO) boost converter is analyzed. The PISO boost converter is derived by combining two basic boost converters. In comparison with the conventional three-level boost converter, the PISO boost converter can balance the output voltages under an unbalanced load condition without requiring additional circuit components and control strategy. A 2 kW prototype converter is built and tested to verify the output voltage balancing characteristics of the PISO boost converter.

내부 불평형 기진력을 갖는 원통형 구조물의 능동진동제어 (Active Vibration Control of Shell Structure Subjected to Internal Unbalanced Excitation)

  • 김승기;정우진;배수룡;이상규;곽문규
    • 한국소음진동공학회논문집
    • /
    • 제27권2호
    • /
    • pp.195-203
    • /
    • 2017
  • This paper is concerned with the active vibration control of shell structure that is subjected to internal unbalanced excitation by using active mounts and accelerometers. The unbalanced excitation is caused by a rotating unbalanced mass. The control algorithm considered in this study is the negative acceleration feedback (NAF) control. A simplified dynamic model was derived to verify the effectiveness of the NAF control. Four actuators and four accelerometers were mounted on the shell structure, so that the multiple-input and multiple-output (MIMO) NAF controller was designed by both centralized and decentralized ways. Numerical results show that both the decentralized and centralized NAF controllers are effective. Based on the numerical simulation, the proposed decentralized NAF controller was applied to the real shell structure. Experimental results show that the proposed decentralized NAF controller can effectively suppress vibrations of the shell structure.

계통연계 인버터의 주요 부하 불평형 시 상전류 제어를 통한 부하 상전압 평형 제어 (An Output Voltage Balance Control of Grid Connected Inverter by Phase Current Control at Critical Load Unbalanced Condition)

  • 박태현;김학원;조관열;민준기;최원일
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.22-29
    • /
    • 2023
  • A grid-connected inverter can be used in grid-connected or stand-alone modes. Generally, a grid-connected inverter operates in a grid-connected mode, but the inverter operates in stand-alone mode if grid faults occur. In the stand-alone mode, the grid-connected inverter must supply electric power to a critical load that needs to receive stable power even though grid faults occur. Generally, three-phase loads are used as critical loads, but a single phase is configured in some cases. In these conditions, the critical load is required to unbalance the load power consumption, which makes the three-phase load voltage unbalancd. This unbalanced voltage problem can cause fatal problems to the three-phase critical loads, and thus must be addressed. Hence, this paper proposes an algorithm to solve this unbalanced voltage problem by the individual phase current control. The proposed method is verified using Psim simulation and experiments.

모듈형 3상 무정전 전원장치의 병렬 운전을 위한 주종 제어 알고리즘 (A Master and Slave Control Algorithm for Parallel Operation of Modular 3-Phase UPS System)

  • 이태영;조영훈;임승범;안창헌
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.479-480
    • /
    • 2016
  • This paper introduces a master and slave control algorithm for parallel operation of UPS system. If each module of UPS system control the output voltage and filter inductor current in parallel operation, it occur unbalanced output power each module. To operate UPS system parallel, it need a algorithm that control output power of modules. A master and slave control algorithm is helpful to balance output power of modules by controlling output current. The effect of a master and slave control algorithm is proved by simulations.

  • PDF

상전압 및 선간전압에 대한 불평형율 (Voltage Unbalance Factor for Phase and Line Voltage)

  • 김종겸;박영진;이동주;이종한;이은웅
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.74-77
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, voltage unbalance is generated at the user's 3-phase 4-wire distribution systems with single & three phase. Voltage unbalance is mainly affected by load system rather than power system. Unbalanced voltage will draws a highly unbalanced current and results in the temperature rise and the low output characteristics at the machine. It is necessary to analyse correct voltage unbalance factor for reduction of side effects in the industrial sites. Voltage unbalance is usually defined by the maximum percent deviation of voltages from their average value, by the method of symmetrical components or by the expression in a more user-friendly form which requires only the three line voltage readings. If the neutral point is moved at the 3-phase 4-wire system by the unbalanced load, by the conventional analytical method, line and phase voltage unbalance leads to different results due to zero-sequence component. This paper presents a new analytical method for phase and line voltage unbalance factor in 4-wire systems. Two methods indicate exact results.

  • PDF

간략화 된 SVPWM을 적용한 4-Switch 3-Phase Inverter의 제어 방법 (Four-switch Three-phase Inverter control method applied by simplified Space Vector PWM)

  • 손상훈;박영주;최익
    • 한국전자통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.283-292
    • /
    • 2016
  • 6스위치 3상 인버터(SSTPI)의 한 상을 스위치 대신 커패시터로 대체한 4스위치 3상 인버터(FSTPI)에서 커패시터 전압의 불평형으로 인한 출력 전압의 오차를 보상하는 방법과 전압 제어 방법은 FSTPI의 성능을 결정짓는 중요한 요소이다. 본 논문에서는 DC 오프셋 전류 주입 통한 FSTPI의 커패시터 전압의 불평형을 보상하는 새로운 방법과 FSTPI의 새로운 전압 제어 방법인 간략화 된 SVPWM을 제안한다. 제안된 방법은 FSTPI로 SPMSM를 구동하는 시뮬레이션과 실험을 통해 그 타당성을 검증하였다.

A Method to Compensate the Distorted Space Vectors in the Unbalanced Neutral Point Voltage of 3-level NPC PWM Inverters

  • Hyun, Seung-Wook;Hong, Seok-Jin;Lee, Jung-Hyo;Lee, Chun-Bok;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.455-463
    • /
    • 2016
  • This paper proposes a compensation method to improve the distorted space vectors when a 3-level Neutral Point Clamped (NPC) inverter has an unbalanced neutral point voltage. Since both the neutral point voltage of the DC link and the space vector of a 3-level NPC inverter are closely related depending on the output load connecting state, a distorted space vector can occur when the neutral point voltage of a 3-level NPC inverter is unbalanced. The proposed method can improve the distorted space vectors by adjusting the injection time of the small and medium vectors and by modulating the amplitude of the carrier waveforms. In this paper, the proposed method is verified by both simulation and experimental results based on a 3-level NPC inverter.