• 제목/요약/키워드: Ultrasound technology

검색결과 495건 처리시간 0.024초

공명초음파 분광법에 의한 광학기기용 렌즈의 비파괴 검사 (Nondestructive Examination of Optical Lens by Resonant Ultrasound Spectroscopy)

  • 김성훈;박상국;김영남;양인영
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.257-262
    • /
    • 2004
  • As optical connectors dominate the performance of optical transmitters or receivers, they need an ultra-precise processing and are composed of optical fibers, ferrule and optical glass lenses. Therefore, this study suggests a nondestructive evaluation technique or a system using resonant ultrasound spectroscopy to evaluate flaws in a optical glass lens. It also conducted a nondestructive evaluation for flaws that are commonly found in a optical glass lens and reviewed the results.

  • PDF

고주파수 초음파 영상을 위한 저잡음·광대역 수신 시스템 구현 (Implementation of low-noise, wideband ultrasound receiver for high-frequency ultrasound imaging)

  • 문주영;이준수;장진호
    • 한국음향학회지
    • /
    • 제36권4호
    • /
    • pp.238-246
    • /
    • 2017
  • 고주파수, 고해상도 초음파 영상을 획득하기 위해서는 고주파수 초음파 변환기가 가지는 작은 구경에 따른 낮은 민감도와 침투 깊이에 따른 높은 감쇠량을 극복하여야 한다. 이는 고주파수 초음파 변환기의 본질적인 한계점이므로 수신 시스템을 통하여 그 한계점을 극복하여야 한다. 본 논문은 고주파수, 고해상도 초음파 영상을 위하여 고주파수 초음파 변환기의 본질적인 한계인 낮은 민감도와 높은 감쇠량을 극복할 수 있는 저잡음 광대역 수신 시스템 개발과 특성 평가 결과에 관한 것이다. 개발한 저잡음 광대역 수신 시스템은 80 MHz 이상의 동작 주파수 대역에서 최대 73 dB의 증폭 이득과 48 dB의 가변 이득 범위를 만족하며 ${\pm}1dB$의 증폭 이득 평탄도 성능을 가진다. 또한 개발한 수신 시스템은 상용 리시버에 비하여 8.4 dB 이상의 신호대잡음비 성능과 3.7 dB 이상의 대조도 성능이 우수함을 확인하였다.

초음파 치료 시 초음파 세기 변화에 따른 생리적 효과 연구 (A Study of Ultrasound Rehabilitation Therapy: Physiological Effects by Change of Ultrasound Intensity)

  • 김성민;이만표;최병철;최상혁;배하석;정회승;박성윤
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.40-45
    • /
    • 2008
  • Therapeutic ultrasound which is developed for rehabilitation therapy have already been used for healing joint contracture, synechia, acute and chronic inflammatory diseases. Medical devices for pain-relief and healing using therapeutic ultrasound are actively being developed. This study measured the change of PTT with the transmitted ultrasound through the human body to find out the increase of compliance of blood vessels. Measurement method of PTT in this study is employed as useful ways to acquire physiological information of patients in the clinical case in order to measure the change of mechanical characteristics of blood vessels. This study confirmed the PTT change of rehabilitation patients through the thermal effects of ultrasound by using PTT and also found that it is possible to increase PTT by adjusting the warm water and ultrasound. The increase of PTT means the decrease of the pulse wave velocity from the cardiovascular system to the peripheral arteries. The physiological effects occurred using the warm water and ultrasound.

Size Control of Silicone Particles Using Sonochemical Approaches

  • Jhung, Sung-Hwa;Yoo, Ki-Cheon;Hwang, Young-Kyu;Chang, Jong-San
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권12호
    • /
    • pp.2401-2404
    • /
    • 2007
  • Particle size of silicones can be controlled by changing the reaction conditions such as temperature and concentrations of water and tetramethoxysilane (TMOS). Alternatively, the use of ultrasound radiation is also an elegant technique to decrease the particle size. Small silicone particles can be obtained at low temperature from diluted reagent containing TMOS, especially under the powerful ultrasound radiation. The size control may be explained by the rate of particle growth rather than that of nucleation.

HIFU: 현황 및 기술적 동향 (High Intensity Focused Ultrasound for Cancer Treatment: Current Agenda and the Latest Technology Trends)

  • 서종범
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권2E호
    • /
    • pp.55-63
    • /
    • 2010
  • High Intensity Focused Ultrasound (HIFU) is a noninvasive surgical method mainly targeting deeply located cancer tissue. Ultrasound is generated from an extemally located transducer and the beam is focused at the target volume, so that selective damage can be achieved without harm to overlying or surrounding tissues. The mechanism for cell killing can be combination of thermal and cavitational damage. Although cavitation can be an effective means of tissue destruction, the possibility of massive hemorrhage and the unpredictable nature of cavitational events prevent clinical application of cavitation. Hence, thermal damage has been a main focus related to HIFU research. 2D phased array transducer systems allow electronic scanning of focus, multi-foci, and anti-focus with multi-foci, so that HIFU becomes more applicable in clinical use. Currently, lack of noninvasive monitoring means of HIFU is the main factor to limit clinical applications, but development in MRI and Ultrasound Imaging techniques may be able to provide solutions to overcome this problem. With the development of advanced focusing algorithm and monitoring means, complete noninvasive surgery is expected to be implemented in the near future.

Magnetic Resonance-Guided Focused Ultrasound in Neurosurgery: Taking Lessons from the Past to Inform the Future

  • Jung, Na Young;Chang, Jin Woo
    • Journal of Korean Medical Science
    • /
    • 제33권44호
    • /
    • pp.279.1-279.16
    • /
    • 2018
  • Magnetic resonance-guided focused ultrasound (MRgFUS) is a new emerging neurosurgical procedure applied in a wide range of clinical fields. It can generate high-intensity energy at the focal zone in deep body areas without requiring incision of soft tissues. Although the effectiveness of the focused ultrasound technique had not been recognized because of the skull being a main barrier in the transmission of acoustic energy, the development of hemispheric distribution of ultrasound transducer phased arrays has solved this issue and enabled the performance of true transcranial procedures. Advanced imaging technologies such as magnetic resonance thermometry could enhance the safety of MRgFUS. The current clinical applications of MRgFUS in neurosurgery involve stereotactic ablative treatments for patients with essential tremor, Parkinson's disease, obsessive-compulsive disorder, major depressive disorder, or neuropathic pain. Other potential treatment candidates being examined in ongoing clinical trials include brain tumors, Alzheimer's disease, and epilepsy, based on MRgFUS abilities of thermal ablation and opening the blood-brain barrier. With the development of ultrasound technology to overcome the limitations, MRgFUS is gradually expanding the therapeutic field for intractable neurological disorders and serving as a trail for a promising future in noninvasive and safe neurosurgical care.

유방의 X선 검사와 초음파 검사의 유용성 연구 (Usefulness of the Mammography and the Breast Ultrasound)

  • 이인자;박계연
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권4호
    • /
    • pp.349-356
    • /
    • 2007
  • 2006년 7월 1일부터 2007년 4월 30일까지 10개월간 1,969명의 유방 X-선 검사 환자와 동일기간 1,531명의 유방 초음파 검사 현지에 대한 분석결과 다음과 같은 결론을 얻었다. 1. 검사자에 대한 연령별 분포를 보면 40, 50대가 많으며, 유방 X-선 검사자 중 68.57%, 유방 초음파 검사자의 71.32%를 차지하였다. 2. 전체 환자 중 질환이 있는 것으로 판정된 환자는 유방 X-선 검사 환자의 31.95%, 유방 초음파 검사자의 45.79%로 나타났다. 3. 질환의 연령별 분포는 유방 X-선 검사 환자는 $30{\sim}60$대, 유방 초음파 검사 환자는 $30{\sim}50$대로 나타났지만, 두 검사법 모두 40대에서 가장 질환이 많은 것으로 나타났으므로 철저한 검사가 필요하다. 4. 유방 X-선 검사와 유방 초음파 검사 시, 질환의 발병부위는 오른쪽과 왼쪽의 차이는 크지 않으나, 유방 X-선 검사에서 양쪽 유방에 질환이 있는 경우가 유방 초음파 검사보다 많은 것으로 나타났다. 5. 전문의에 의한 판독 결과 유방 X-선 검사에서 질환은 Calcification, Nodular, Mass 순이고, 유방 초음파 검사에서 질환은 Cyst, Nodular, Mass 순으로 발견율이 높았다. 6. 판독결과 유방 X-선 검사에서는 1가지 질환으로 판정되는 율이 89.3%로 높으나, 유방 초음파 검사에서는 2가지 이상의 질환을 가진 환자가 16.7%로 유방 X-선 검사의 10.7% 보다 많았다.

  • PDF

A Cost-effective Light Emitting Diode-acoustic System for Preclinical Ocular Applications

  • Choi, Hojong;Ryu, Jaemyung;Yeom, Jung-Yeol
    • Current Optics and Photonics
    • /
    • 제2권1호
    • /
    • pp.59-68
    • /
    • 2018
  • Opto-acoustic systems provide structural and functional information regarding biological tissues. Conventional opto-acoustic systems typically employ continuous or pulsed lasers as transmission sources. Compared to lasers, light emitting diodes (LEDs) are cost-effective and relatively portable excitation sources but are non, coherent. Therefore, in this study, a relatively low cost lens - a type of Ramsden eyepiece - was specially designed to theoretically calculate the illumination and achieve a constant brightness across the pupil of an eye. In order to verify the capability of the developed light-emitting diode-acoustic (LEDA) systems, we carried out experiments on bovine and bigeye tuna eyeball samples, which are of similar size to the human eye, using low frequency (10 MHz) and high frequency (25 MHz) ultrasound transducers. High frequency ultrasound transducers are able to provide higher spatial resolution compared to low frequency ultrasound transducers at the expense of penetration depth. Using the 10 MHz and 25 MHz ultrasound transducers, acceptable echo signals (3.82, 3.94, and 5.84 mV at 10 MHz and 282, 1557, 2356 mV at 25 MHz) from depth greater than 3 cm and 6 cm from the anterior surface of the eye were obtained. We thereby confirmed that the LEDA system using a pulsed LED with the designed Ramsden eyepiece lens, used in conjunction with low and high frequency ultrasound transducers, has the potential to be a cost-effective alternative method, while providing adequate acoustic signals from bovine and bigeye tuna ocular areas.

Combined Effects of Ionizing Radiation and Ultrasound on Malformation in ICR Mice at Organogenesis stage

  • 구연화;하세가와 다케오;모리 다케히코;야마모토 요우치;구사마 토모코
    • Journal of Radiation Protection and Research
    • /
    • 제24권1호
    • /
    • pp.23-30
    • /
    • 1999
  • 태생 8일째인 임신한 생쥐에 137-Cs 감마선과 초음파를 조사하였다. 복합조사의 경우 임신한 생쥐는 1.5 Gy 방사선과 $1.0W/cm^2$ 초음파로 -1, 0, 1, 3, 6 시간 간격으로 조사하였다. 사망과 외부 기형은 태생 18일에 검진하였다. 방사선에 의한 태생 8일의 사망 임계값은 0.5에서 1.0 Gy사이였으며, 초음파는 1.0에서 $1.5W/cm^2$ 사이였다. 태생 후반기의 사망은 방사선과 초음파의 복합 치료에 의해 상승적으로 증가되었다. 방사선에 의한 뇌탈출기형 및 무안구증의 임계값은 각각 0.5에서 1.0Gy사이와 1.0에서 1.5Gy 사이였다 초음파에 의한 뇌탈출기형과 무안구증의 임계값은 각각 1.0에서 $1.5W/cm^2$ 사이와 $1.5W/cm^2$ 이상이었다. 복합치료의 경우는 뇌 탈출기형과 무안구증의 빈도가 상승적으로 증가하였다. 한 시간 간격으로 두 가지 치료를 받은 생쥐에서 뇌 탈출기형과 무안구증의 빈도가 최고치에 도달하였다.

  • PDF

초음파에 의한 carrageenan 저분자화의 최적 조건 (Optimal Processing Parameters of Low Molecular Weight Carrageenan by Ultrasound)

  • 김상무;박성민;최현미;이근태
    • 한국수산과학회지
    • /
    • 제32권4호
    • /
    • pp.495-500
    • /
    • 1999
  • [ $\lambda$ ]-carrageenan 고유의 특성을 유지하면서 용해성을 높인 저분자 $\lambda$-carrageenan을 제조하여 보다 효율적으로 식품산업에 이용하기 위하여 초음파를 이용하여 $\lambda$-carrageenan을 저분자화하는 최적조건을 조사한 결과 $\lambda$-carrageenan의 초음파 처리시 각 처리조건들과 저분자화 효과와의 상관관계를 나타내는 반응표면식을 구한 결과, carrageenan 농도와 초음파 강도가 저분자화에 미치는 주 영향인자인 것으로 나타났다. 그리고 저분자화를 위한 초음파 처리의 최적 조건은 초음파 처리온도 $10^{\circ}C$, 초음파 강도 121.64 $W/cm^2$, 시료 carrageenan 농도 $2\%$, 초음파 처리시간 40분이었다. $\lambda$-carrageenan 및 저분자화된 $\lambda$-carrageenan의 분자량을 조사한 결과 대조구 $\lambda$-carrageenan의 분자량은 약 250,000이었으며 초음파처리에 따른 저분자화 된 $\lambda$-carrageenan의 분자량은 각각 p-1의 경우 약 200,000정도였으며, p-2의 경우 약 60,000정도이었다.

  • PDF