• Title/Summary/Keyword: Ultrasound technology

Search Result 495, Processing Time 0.033 seconds

Study on Velocity In-homogeneous Effect in fat and its Correction in Ultrasound Imaging System (초음파 의료영상에서 지방조직의 음속도 불균일 효과의 영향과 그 보상에 관한 연구)

  • Kim, Jae-Hyeon;Bae, Mu-Ho;Jeong, Mok-Geun
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.9-18
    • /
    • 1998
  • In this paper, we present the degradation of focusing induced by velocity inhomogeneity in human tissue. For simulation, the fatty layer which is the major factor of degradation for its lower velocity, is modeled as a uniform velocity perturbation layer. And we simulate the degradation of resolution resulting from change of beam path due to refraction and the time delay due to velocity difference. We show that focusing error can be compensated for considering the velocity inhomogeneity only. The proposed compensation method can be operated in real time in the presently used digital focusing systems.

  • PDF

The Scanning Laser Source Technique for Detection of Surface-Breaking and Subsurface Defect

  • Sohn, Young-Hoon;Krishnaswamy, Sridhar
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.246-254
    • /
    • 2007
  • The scanning laser source (SLS) technique is a promising new laser ultrasonic tool for the detection of small surface-breaking defects. The SLS approach is based on monitoring the changes in laser-generated ultrasound as a laser source is scanned over a defect. Changes in amplitude and frequency content are observed for ultrasound generated by the laser over uniform and defective areas. The SLS technique uses a point or a short line-focused high-power laser beam which is swept across the test specimen surface and passes over surface-breaking or subsurface flaws. The ultrasonic signal that arrives at the Rayleigh wave speed is monitored as the SLS is scanned. It is found that the amplitude and frequency of the measured ultrasonic signal have specific variations when the laser source approaches, passes over and moves behind the defect. In this paper, the setup for SLS experiments with full B-scan capability is described and SLS signatures from small surface-breaking and subsurface flaws are discussed using a point or short line focused laser source.

Observation with Calcifications of Breast Tissue Phantoms Using Acoustic Resonance (공명현상을 이용한 유방조직 팬텀의 석회화 관찰)

  • Ha, Myeung-Jin;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.61-69
    • /
    • 2008
  • Diagnosis of breast ultrasound is better than mammography in the early detection of breast cancer, but, it is difficult to detect microcalcification. We studied on detection for calcification of breast tissue using acoustic resonance and power doppler with 7.5 MHz linear probe in breast ultrasound. We first constructed breast tissue phantom made of gelatin and saw breast, and then observed calcification by the change of external vibration. Calcification injected breast tissue phantom visualized the difference for brightness and region of color in ROI regions of power doppler. Acoustic resonance almost never visualized in low frequency regions, plateau constituted in about 300-400 Hz and colors vanished according to the increase of frequency.

  • PDF

Fabrication and Properties of ferroelectric BST thin films prepared by sol-gel method (II) - effect of ultrasound on properties of thin film (졸-겔법에 의한 강유전 BST 박막의 제조 및 특성(II) - 초음파의 효과)

  • 이진홍;박병옥;이승엽
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.11 no.6
    • /
    • pp.252-258
    • /
    • 2001
  • ($Ba_{0.7}Sr_{0.3})TiO_3$thin films were perpared on ITO-coated glass substrate by spin-coating method. The sol was sonicated in an ultrasonic bath to promote homogenization and the results were compared with untreated case. By application of the sonication process, crystallization temperatures of films were reduced, microstructers of films were more uniform and denser and the surface roughness of the films was lower from 8.4nm to 5.6nm. In addition, optical transmittances and electrical properties of films prepraed from sonicated sol were superior to those of films from untreated.

  • PDF

Quantitative evaluating method for diagnostic ultrasound probe using 3-dimensional acoustic field analysis (3차원 음장 분석법을 이용한 진단용 초음파 프로브의 정량적 성능평가)

  • Noh, Si-Cheol;Kim, Ju-Young;Park, Jae-Hyun;Kim, Jin-Su;Kang, Jung-Hoon;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.490-496
    • /
    • 2010
  • In this study, in order to overcome the weakness of acoustic field analysis which is generally used for ultrasonic probe performance evaluation, automatic acoustic field measurement system and evaluation parameters were proposed. The comparisons between acoustic field simulation and measured acoustic distribution data of normal and abnormal channels were conducted to evaluate the availability of proposed system and evaluation parameters. First, the impulse response characteristic of sample probe was investigated to classify the normal elements and abnormal elements. And then, normal channels and abnormal channels with abnormal element were chosen. The suggested 12 evaluation parameters were calculated using the acoustic fields of these channels. The availability of proposed automatic acoustic field measurement system and evaluation parameters was confirmed. And the performance evaluation of ultrasonic probe using acoustic field analysis could be easier and faster.

Physiotherapy Approach to Patients with Chronic Plantar Fasciitis : Comparison of the Effects of Specific Stretching Exercise and High-Load Strengthening Exercise (만성 발바닥 근막염 환자에 대한 물리치료적 접근법: 특이적 뻗침운동과 고부하 강화 운동의 효과 비교)

  • Choo, Yeon-Ki;Bae, Won-Sik
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.1
    • /
    • pp.151-161
    • /
    • 2021
  • Purpose : This study was to investigate the effectiveness of ESWT and plantar fascia-specific stretching exercise vs ESWT and high-load strengthening exercise in patients with chronic plantar fasciitis. Methods : The subjects were randomized to extracorporeal shock wave therapy ( ESWT, for 3 weeks) and daily plantar-specific stretching (Group I: Stretch group) or ESWT and high-load progressive strength (Group II: Strength group) performed every second day. The main outcome measures were ultrasound, visual analogue scale (VAS), and Korean Foot Function Index (KFFI). The ultrasound (plantar fascia thickness), pain intensity I, II (the most painful of the day?, the pain when you first step in the morning?) and KFFI (functional performance) were compared between the groups. Results : No significant difference was observed between the groups in the plantar fascia thickness but pain intensity I, II was significantly lower in Group 2 than in Group 1 at only 12weeks and functional performance was also significantly increased in Group 2 compared to Group 1 at only 12 weeks. Conclusion : The high-load strengthening exercise consisting of the progressive exercise protocol, resulted in superior after 12 weeks compared with plantar-specific stretching. High-load strength exercise may aid in a quicker reduction in pain and improvements in functional performance.

A Study on the Radiographic Diagnosis of Caroli's Disease (카롤리병의 방사선학적 진단에 대한 고찰)

  • Yeo-jin Hong;Min-a Kim;Soo-bin Kim;Jin-joo Song;Kyoung-hoon Jang;Min-cheol Jeon;Man-Seok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.385-392
    • /
    • 2023
  • Caroli's disease is a fibrocystic liver disease. Autosomal recessive disorder is characterized by congenital multiple dilatation of the bile duct. Computerized tomography, magnetic resonance imaging, cholangiography and ultrasound are among the methods for diagnosing caroli disease. Computerized tomography is essential for detecting and distinguishing fibroplastic liver disease and is useful for determining intrahepatic bile duct dilatation. However, awareness of the possible side effects of using contrast mediums is necessary. A typical method of magnetic resonance cholangiography is used for magnetic resonance imaging. A non-invasive examination can reduce the pain of the patient, and the anatomical structure of the bile pancreatic duct and the presence or absence of lesions can be easily and quickly observed. Biliary contrast is an effective diagnostic method that can directly visualize various cystic dilatations throughout the enlarged bile duct. However, since this procedure is also an invasive procedure, it is recommended not for diagnosis but for treatment purposes. Ultrasonography can confirm similar findings to computerized tomography. The hepatic artery root is difficult to prove with conventional grayscale ultrasound. However, it is of clinical value in that it can not only describe dilated bile ducts with vascular roots in the tube but also easily identify color Doppler signals in the tube. With the development of video diagnostics, early diagnosis has become possible through computerized tomography, magnetic resonance imaging, cholangiography, and ultrasound. In order to further contribute to the development of video diagnostics so that long-term prognosis can be improved after treatment through early diagnosis, we examined what aspects of each test's caroli disease appear.

Study on the Micro Crack Detection in Joints by Using Ultrasound Infrared Thermography (초음파 적외선 열화상을 이용한 접합부의 미세균열 검출 연구)

  • Park, Hee-Sang;Choi, Man-Yong;Park, Jeong-Hak;Lee, Seung-Seok;Huh, Yong-Hak;Lee, Bo-Young;Kim, Jae-Seong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.162-169
    • /
    • 2012
  • This study detected SCC defects of dissimilar metal welded(STS304 and SA106 Gr. b) pipes using the ultrasonic infrared thermography method and the lock-in image treatment method among infrared thermography method. The infrared excitement equipment has 250 Watt of output and 20 kHz of frequency. By using the ultrasound infrared thermography method, the internal defects of dissimilar metal weld joints of pipes used at nuclear power plants could get detected. By an actual PT test, it was observed that the cracks inside the pipe existed not as a single crack but rather as a multiple cracks within a certain area and generated a hot spot image of a broad area on the thermography image. In addition, UT technology could not easily defects detected by the width of $10\;{\mu}m$ fine hair cracks. but, ultrasound infrared thermography technique was defect detected.

Analysis on Developmental Factors of the Liver Diseases in Ultrasound Diagnosis of Healthcare (종합검진 초음파검사에서 나타난 간질환과 건강관련 요인분석)

  • Lee, Mi-Yeon;Jung, Hong-Ryang;Lim, Chang-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.79-86
    • /
    • 2009
  • The study found out developmental factors of the liver diseases in 29, 531 cases of the healthy adults who were diagnosed by using ultrasound at domestic healthcare centers in 6 cities. The results are as follows. Based on the result of the study, the liver diseases diagnosed by using ultrasound was revealed to show 43.1% of prevalence, and the occurrence was significantly higher in male (23.3%) than in female (19.8%). The prevalence of hepatic diseases related to the BMI was revealed to show highest prevalence of the fatty liver in obese group (BMI $\geqq$ 25) by recording 44.3%. Smoking contributed to the high prevalence of all liver diseases. Although the fatty liver was the most frequently occurred form of liver diseases by recording the prevalence of 49.1% (22.2% in male, 26.9% in female), the significant difference was found only in female (p < 0.05), but male group did not show significant difference (p > 0.05). The prevalence of hepatic diseases related to the hypertension was revealed to show highest prevalence of the fatty liver in hypertension group by recording 67.7%. The prevalence of hepatic diseases related to the diabetes was revealed to show highest prevalence of the fatty liver in diabetes group by recording 66.2%. The high prevalence of all hepatic diseases was related to diabetes mellitus with statistical significance (p < 0.001). The multiple regression analysis for the related factors which affect the prevalence of the liver diseases showed the higher prevalence by age. Sex, obesity and diabetes mellitus were positively related to the prevalence (p < 0.05) while hypertension and smoking showed no significant relationship to the prevalence of the disease (p > 0.05).

  • PDF

Effect of ultrasonication, salt solution and liquid smoke treatment on germination of Setaria italica seeds

  • Kim, Young Ae;Kim, Min Geun;Oh, Ju-Sung;Kim, Du Hyun
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.215-215
    • /
    • 2017
  • The preference for domestic cereal crop of Setaria Italica has been increased with the recent interest in healthy foods. However, the productivity of Korean domestic produce, which has been decreasing due to the lack of cultivation technology and the low rate of mechanization during cultivation. Increase of germination ability will have a positive effect on the cultivation by reducing the labor of the manpower consuming and weeding work. Therefore, red light, ultrasonication, liquid priming and liquid smoke treatment that are effective for the germination of the seeds evaluated. The seeds of 1.4mm or more were used for the experiment. The priming solution used in the experiment was 1% $KH_2PO_4$ (74mM). During the priming, the light treated seeds at 2000 lux for 15, 30, 60 and 120 minutes. Ultrasonicationd treatment was performed for 5, 10, and 20 minutes at exposures of 60%, 80%, and 100% of ultrasound up to 21.6 kHz during priming. Light or ultrasound treated seeds transferred to priming treatment at $15^{\circ}C$ for 24 hours. The treatment of the liquid smoke was divided into the treatment of the liquid smoke alone and the treatment of the liquid smoke with the priming. The liquid smoke alone was diluted with distilled water without priming solution and the treatment of the liquid smoke was diluted with the salt priming solution. Both treatments were performed at 0.0%, 0.5%, 1.0%, 5.0%, and 10.0% of the liquid smoke (pH7) concentration at $15^{\circ}C$ for 6 hours. After each treatment, the seeds were dried to moisture content ranged 5-8% at $25^{\circ}C$ for 24 hours. All treatments showed better results than the non-treated control. Light treatment for 120 minutes improved for germination percentage (GP), Germination uniformity (GU) and heath seed percentage (HS). Ultrasonication treatment was most effective when treated with ultrasound at 21.6 kHz for 5 minutes in all germination characteristics. Ten % of the liquid smoke increase in 92% GP, 1.8 days MGT, $54%{\cdot}day^{-1}GR$, 0.76 GU and 88% HS comparing to non-treated control (72% GP, 2.3 days MGT, $45%{\cdot}day^{-1}GR$, 1.48 GU, and 63 % HS). This study showed that it is possible to obtain high germination by adding liquid smoke treatment to the seeds supplied to the farmers. The efficacy of light, ultrasonication, inorganic salt priming, and liquid smoke treatment on the seeds found in the experiment will be a positive alternative to labor force problems in the cultivation by improving germination.

  • PDF