• 제목/요약/키워드: Ultrasound technology

Search Result 495, Processing Time 0.035 seconds

Sonolysis of Trichloroethylene in a Continuous Flow Reactor with the Multi Ultrasound Irradiation (연속식 다중 초음파 반응조에서 TCE의 초음파 분해)

  • Lee, Min-Ju;Oh, Je-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.6
    • /
    • pp.419-427
    • /
    • 2009
  • To test applicability for continuous flow treatment of ultrasound technology, sonolysis of TCE aqueous solution using 584 kHz multi irradiation reactor was performed under batch and continuous flow conditions. Under batch condition (3 and 4 sides irradiation, 600 W), first order degradation rate constant of TCE was higher under 4 sides than 3 sides irradiation conditions, while the generation of $H_2O_2$ and chloride was similar under both irradiation conditions. Under continuous flow condition with 4 sides irradiation, removal efficiencies of TCE in steady-state were decreased from 83 to 48% with increasing flow rate from 67 to 300 mL/min at 600 W, and were increased from 14 to 75% with increasing acoustic power from 100 to 600 W at 100 mL/min. Removal efficiency of TCE in groundwater was decreased 10% compared to in distilled water at 100 mL/min and 600 W.

Study on Convergence Using Carotid Ultrasonography in Metabolic Syndrome risk factor (경동맥초음파 검사를 활용한 대사증후군 인자의 융합연구)

  • Sung, Hyun-Ho;Yoon, Joon
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.6
    • /
    • pp.195-200
    • /
    • 2015
  • This study conducted a comprehensive health examination center in healthy adult subjects 47 people in the 30-55 age carotid ultrasound and a blood test and measurement physique is located in Gyeonggi Province in 2014, was analyzed in the same group between gender and age of the person hip circumference was higher than the 40s and 50s(p<0.05). Carotid ultrasound results showed differences in the 30s and 50s (p<0.05). CIMT and BMI, in CIMT showed a positive correlation with hip circumference (p<0.05). In addition, blood pressure and systolic blood pressure in the CIMT showed a positive correlation (p<0.05). In conclusion, in this study, we demonstrated a correlation between metabolic syndrome risk factor in carotid IMT, and continue to research needed for the diagnosis of diseases of the metabolic syndrome factor fusion research is utilizing ultrasound for a more qualitative disease diagnosis.

Effects of Microwave, Ultrasound and Roasting Pretreatments on Hot Water Extraction of Acanthopanax senticosus (마이크로파, 초음파 및 볶음 전처리가 오가피의 열수 추출특성에 미치는 영향)

  • Chung, Hun-Sik;Youn, Kwang-Sup
    • Food Science and Preservation
    • /
    • v.12 no.2
    • /
    • pp.146-150
    • /
    • 2005
  • A comparative study of pretreatment and extraction methods was conducted to investigate their effects on nutritional and bioactive components during hot-water extraction of Acanthopanax senticosus. The herb samples, ground and sifted $(8\~20\;mesh)$ were pretreated with ultrasound (20 kHz), microwave (2,450 MHz) or roasting $(180^{\circ}C)$ for 10 min, and then extracted by a boiling $(180^{\circ}C)$ under atmospheric pressure or a pressured boiling $(121^{\circ}C)$ for 2 hr. In general, the pretreatments improved the extraction efficiency and the DPPH radical scavenging activity of extract. Particularly, the extraction yields of soluble solids, total sugar and phenolic compounds were increased in microwaving methods, and the protein yield and the radical scavenging activity were higher in roosting pretreatment. Yields of soluble solids, total sugar, protein and phenolic compouds in pressured extraction were higher than those in nonpressured extraction. These results suggested that pretreatment including microwave radiation, sonication and roasting and pressured extraction can be utilized for improving the extraction efficiency of A. senticosus.

Analysis of Harmonic Wave Generation in Nonlinear Oblique Crack Surface (비선형 경사 균열면에서의 고조파 발생 특성 해석)

  • Kim, Noh-Yu;Yang, Seung-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.376-387
    • /
    • 2012
  • Based on the nonlinear spring model coupled with perturbation method, 2nd harmonic waves generated by oblique incident ultrasound on nonlinear crack interface were calculated and investigated. Reflected and transmitted waves from the interface were determined and analyzed at various angle of incidence for the cracks with different interfacial stiffness in order to estimate the 2nd harmonic generation of incident ultrasound. It was shown in computer simulation that the 2nd harmonic components changed much with the increase of incidence angle in both reflected and transmitted wave, but became very small when the incident angle approached toward 90 degree. It can be concluded that the 2nd harmonic component of reflected wave has a meaningful amplitude as much as the transmitted 2nd harmonic wave from partly closed crack.

The Impacts of Piezoelectric Elements' Defects On Color & Power Doppler Images (초음파 프로브에서 소자결함이 컬러 및 파워 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2015
  • An ultrasound probe has a big impact on Doppler images even though it has very high risk of frequent function-breakdowns occurring in medical ultrasound scanners. This study experimentally analyses the impacts of an ultrasonic probe's defected elements on power & color Doppler images. The results show that, the bigger the size of defected probe elements is, and the closer a group of action elements is to the center, the more the brightness of images and the velocity of Doppler diminish. When elements' defects increase in color & power Doppler images, false images are formed to be mistaken for blood-vessel plaque in neighboring regions. Accordingly, whenever element defects are suspected, we need check-up process in B-mode. From this respective, it is advisable to have primary interest in a probe and carry out continuous probe QA for ultrasonography.

Polymerization of Polystyrene Latex using Ultrasound Energy Effect (초음파 에너지를 이용한 Polystyrene Latex의 중합 특성)

  • Kim, Hyung Jin;Kim, Won II;Lee, Seung Bum;Hong, In Kwon
    • Applied Chemistry for Engineering
    • /
    • v.8 no.6
    • /
    • pp.886-892
    • /
    • 1997
  • There are many methods to synthesize polystyrene latex. Emulsion polymerization technique is commonly used commercially, but it requires a new technology to replace a traditional polymerization method because of the disadvantage of chemical initiator for environmental pollution. Since free radicals can be produced by ultrasound energy effect, polystyrene latex was synthesized using ultrasound energy instead of chemical initiator. As the ultrasonic irradiation time was increased, average molecular weight was increased and polydispersity was decreased. The degree of polymerization was increased with the concentration of SDS and maximum degree of polymerization was shown at 2wt.% SDS concentration and the reaction temperature of $40^{\circ}C$. During the course of polymerization, molecular weight was repeatedly fluctuated because of occurrence of depolymerization. Narrow molecular weight distribution polystyrene latex having controlled molecular weight was synthesized by controlling ultrasonic irradiation time and the concentration of SDS.

  • PDF

Effective Adaptive Dynamic Quadrature Demodulation in Medical Ultrasound Imaging

  • Yoon, Heechul;Jeon, Kang-won;Lee, Hyuntaek;Kim, Kyeongsoon;Yoon, Changhan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.468-475
    • /
    • 2018
  • In medical ultrasound imaging, frequency-dependent attenuation downshifts and reduces a center frequency and a frequency bandwidth of received echo signals, respectively. This causes considerable errors in quadrature demodulation (QDM), result in lowering signal-to-noise ratio (SNR) and contrast resolution (CR). To address this problem, adaptive dynamic QDM (ADQDM) that estimates center frequencies along depth was introduced. However, the ADQDM often fails when imaging regions contain hypoechoic regions. In this paper, we introduce a valid region-based ADQDM (VR-ADQDM) method to reject the misestimated center frequencies to further improve SNR and CR. The valid regions are regions where the center frequency decreases monotonically along depth. In addition, as a low-pass filter of QDM, Gaussian wavelet based dynamic filtering was adopted. From the phantom experiments, average SNR improvements of the ADQDM and the VR-ADQDM over the traditional QDM were 1.22 and 5.27 dB, respectively, and the corresponding maximum SNR improvements were 2.56 and 10.58 dB. The contrast resolution of the VR-ADQDM was also improved by 0.68 compared to that of the ADQDM. Similar results were obtained from in vivo experiments. These results indicate that the proposed method would offer promises for imaging technically-difficult patients due to its capability in improving SNR and CR.

Algorithms for Ultrasound Elasticity Imaging (초음파 탄성 영상 알고리듬)

  • Kwon, Sung-Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.484-493
    • /
    • 2012
  • Since the 1980s, there have been many research activities devoted to quantitatively characterizing and imaging human tissues based on sound speed, attenuation coefficient, density, nonlinear B/A parameter, etc., but those efforts have not yet reached the stage of commercialization. However, a new imaging technology termed elastography, which was proposed in the early 1980s, has recently been implemented in commercial clinical ultrasound scanners, and is now being used to diagnose prostates, breasts, thyroids, livers, blood vessels, etc., more quantitatively as a complementary adjunct modality to the conventional B-mode imaging. The purpose of this article is to introduce and review various elastographic algorithms for use in quasistatic or static compression type elasticity imaging modes. Most of the algorithms are based on the crosscorrelation or autocorrelation function methods, and the fundamental difference is that the time shift is estimated by changing the lag variable in the former, while it is directly obtained from the phase shift at a fixed lag in the latter.

Intelligent Collision Prevention Technique for Construction Equipment using Ultrasound Scanning (초음파 스캐닝을 활용한 지능형 건설기계 충돌방지 기술)

  • Lee, Jaehoon;Hwang, Yeongseo;Yang, Kanghyeok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.5
    • /
    • pp.48-54
    • /
    • 2021
  • According to the Ministry of Employment and Labor's statistics on occupational fatalities in South Korea, more than half of the fatalities in the past five years have occurred in the construction industry. The stuck-by and caught-in-between accidents associated with construction equipment is the major source of fatalities from construction sites. In order to prevent such accidents in construction sites, the government has spent lots of efforts including proposing the "special law on construction safety" and encouraging the implementation of new technology for accident prevention. However, numerous accidents are still occurred at construction sites and further efforts are still required. In this manner, this study developed a collision prevention technique that can prevent collision between equipment and worker by recognizing location and type of the nearby objects through ultrasound scanning. The study conducted a pilot experiment and the analysis results demonstrate the feasibility of achieving high performance in both object recognition and location estimation. The developed technique will contribute to prevent collision accidents at construction sites and provide the supplemental knowledge on developing automated collision prevention system for construction equipment.

Accuracy and Usefulness of Volume Measurement using CT and Ultrasound Scan Data (CT 및 초음파 스캔 데이터를 이용한 체적 측정의 정확도 및 유용성)

  • Kim, Hyeon-Ju;Lee, Hoo-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.289-294
    • /
    • 2022
  • In this study, the accuracy and usefulness of volume measurement were investigated as a phantom experiment using CT and USG scan data and a clinical trial using patient scan data. As a result, there was no significant difference between the volume of the actual round phantom of various volumes for both the CT and ultrasound devices (p>0.05). As a result of statistical analysis, it was analyzed that there was no significant difference (p>0.05). Clinical application of this result requires more clinical trials, but if a CT or ultrasound device is selected and applied in consideration of patient radiation exposure, the examiner's scanning technology, and CT reconstruction experience, the basic data in terms of the usefulness of volume measurement using CT scan image is considered to have application value.