• Title/Summary/Keyword: Ultrasound sonography

Search Result 57, Processing Time 0.028 seconds

Usefulness of Sonography Guided Charcoal Suspension Tattooing in Localization of Cervical Nodal Recurrence after Thyroidectomy: Preliminary Report (갑상선암 수술 후 재발한 경부림프절의 위치 확인에 있어서 초음파 유도하 참숯 현탁액 표식의 유용성: 예비보고)

  • Lee, Jong Cheol;Han, Myung Woul;Lee, Jeong Hyun;Roh, Jong-Lyel;Nam, Soon Yuhl;Kim, Sang Yoon;Choi, Seung-Ho
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.1
    • /
    • pp.35-39
    • /
    • 2011
  • Objectives The high sensitivity of ultrasound and thyroglobulin determination for follow-up of differentiated thyroid cancer allows early detection of nonpalpable recurrences. Intraoperative localization of these small foci in previously dissected necks is a surgical challenge. We assessed the safety and effectiveness of ultrasound-guided tattooing (US-tattoo) with a charcoal suspension for localizing nonpalpable cervical recurrences after thyroidectomy for thyroid cancer. Subjects and Methods Between March 2009 and December 2010, we retrospectively reviewed 19 patients who underwent US-tattoo with injection of a charcoal suspension for recurrent thyroid papillary cancer on central neck compartment after thyroidectomy. All patients underwent the surgical dissection after US-tattoo. The complications and effectiveness of US-tattoo were evaluated. Results The technical success rate of US-tattoo for suspicious lesions was 100%. There was no complication with regard to US-tattoo. During surgery, all but one tattooed lesions were detected by surgeons. On final pathologic reports, all recurrence lesions but two cases were successfully removed. Conclusion Preoperative US-tattoo is a safe and effective method for successful reoperation of central neck compartment recurrences after thyroidectomy.

  • PDF

The Results of Ultrasound Examination of the Elbow in Middle School Baseball Players (중학교 야구선수에서 시행한 주관절 초음파 검사의 결과)

  • Hwang, Tae Hyok;Cho, Hyung Lae;Wang, Tae Hyun;Jin, Hong Ki
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.89-97
    • /
    • 2014
  • Purpose: To evaluate the ultrasonographic findings of the elbows on group screening of middle school baseball players. Materials and Methods: Ninety-three players (age: 12-15, mean 13.5 years) of four middle school baseball team were evaluated with bilateral elbow ultrasonographies in the field regardless of elbow pain. Medial and anterolateral ultrasound examination of the both elbow were performed in the field to detect any abnormalities including medial epicondylar separation or fragmentation and capitellar osteochondritis dissecans respectively. We analyzed the relationship among elbow pain, physical findings and sonographic abnormalities and the differences of sonographic abnormalities between pitchers and fielders. Results: Thirty-six of 93 (39%) players had sonographic abnormalities of elbow in dominant arm, 30 with medial epicondylar apophyseal separation or fragmentation, 2 with osteochondritis dissecans, 4 with both lesions. Twenty-nine of 37 (78%) players with elbow pain had sonographic abnormalities. On physical examination, players with medial epicondylar abnormalities had medial epicondylar tenderness (59%) and pain on valgus stress test (52%), and 5 of 6 (83%) players with osteochondritis dissecans showed flexion contracture more than $5^{\circ}$. The incidence of medial epicondylar abnormalities between pitchers and fielders was statistically not significant but osteochondritis dissecans was more prevalent in pitchers (p<0.05). Conclusion: Elbow sonography is a simple and useful screening tool in the field and also effective for early detection of medial epicondylar abnormalities or osteochondritis dissecans that could be the main causes of elbow pain in adolescent baseball players.

  • PDF

Diagnostic Consistency between Sonoelastography and Conventional Sonography of Long Head of the Biceps

  • Yoon, Sunghyun;Seo, Joong-Bae;Yoo, Jae-Sung;Ryu, Jee-Won
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.3
    • /
    • pp.107-113
    • /
    • 2014
  • Background: Sonoelastography (SE) is a new technique that can assess differences in tissue stiffness, the purpose of this study was to evaluate the ability of SE to assess the long head of biceps tendon alteration. Methods: Forty shoulders of 36 consecutively registered patients with clinical symptoms and conventional ultrasonography findings of biceps tendinitis or tendinosis, and 40 asymptomatic shoulders of 20 healthy volunteers were assessed with SE. Transverse and longitudinal images of long head of biceps tendon were obtained using SE. SE images were performed by one orthopedic surgeon and evaluated by two orthopedic surgeons using an experimentally proven color grading system. Results: The transverse images of SE showed a sensitivity of 87.5%, a specificity of 95.0% and a accuracy of 91.3%, the longitudinal images of SE showed a sensitivity of 92.5%, a specificity of 90.0% and a accuracy of 91.3%. Inter-observer reliability of SE was in 'almost perfect agreement' with a weighted kappa coefficient of 0.83. Conclusions: SE is valuable in the detection of the intratendinous and peritendinous alterations of biceps tendon, and has excellent accuracy and excellent correlation with conventional ultrasound findings.

Use of Omega-3 Polyunsaturated Fatty Acids to Treat Inspissated Bile Syndrome: A Case Report

  • Jun, Woo Young;Cho, Min Jeng;Han, Hye Seung;Bae, Sun Hwan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.19 no.4
    • /
    • pp.286-290
    • /
    • 2016
  • Inspissated bile syndrome (IBS) is a rare condition in which thick intraluminal bile, including bile plugs, sludge, or stones, blocks the extrahepatic bile ducts in an infant. A 5-week-old female infant was admitted for evaluation of jaundice and acholic stool. Diagnostic tests, including ultrasound sonography, magnetic resonance cholangiopancreatography, and a hepatobiliary scan, were not conclusive. Although the diagnosis was unclear, the clinical and laboratory findings improved gradually on administration of urodeoxycholic acid and lipid emulsion containing omega-3 polyunsaturated fatty acids (PUFAs) for 3 weeks. However, a liver biopsy was suggestive of biliary atresia. This finding forced us to perform intraoperative cholangiography, which revealed a patent common bile duct with impacted thick bile. We performed normal saline irrigation and the symptom was improved, the final diagnosis was IBS. Thus, we herein report that IBS can be treated with omega-3 PUFAs as an alternative to surgical intervention.

A Case of Infantile Hemangioendothelioma of the Liver Treated with Hepatic Embolization and Lobectomy (간동맥 색전술과 간엽 절제술로 치료한 영아 간내 혈관내피종 1례)

  • Kim, Jae Seon;Moon, Soo Kyung;Yoon, Hye Seon;Lee, Tae Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.6
    • /
    • pp.660-664
    • /
    • 2005
  • Infantile hemangioendothelioma(IHE) of the liver is the most common vascular tumor in infants before the age of 6 months. It is a histologically benign tumor with potentially life-threatening complications. The clinical manifestations are variable, ranging from asymptomatic forms to intractable high-output heart failure. In addition, abdominal mass, intraperitoneal hemorrhage due to rupture of mass, respiratory distress, hematologic abnormalities and jaundice can occur. Diagnostic work-up is through doppler ultrasound sonography, computed tomography scan, magnetic resonance imaging and angiography. Treatment consists of medical treatment, interventional therapy, surgical resection and liver transplantation. We experienced symptomatic IHE in a premature neonate who presented with high output heart failure and respiratory distress. Initial medical treatment and steroid therapy failed to improve his condition. Coil embolization of left hepatic artery resulted in improvement of respiratory symptoms. However, a left lobectomy was performed because the mass size was not decreased with development of collateral vessels. The infant was well, after a successful discharge from the hospital.

Evaluation of Quantitative Image Quality using Frequency and Parameters in the Ultrasound Image (초음파영상에서 주파수와 파라미터를 이용한 정량적 영상평가)

  • Kim, Changsoo;Kang, Se Sik;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.247-253
    • /
    • 2016
  • Ultrasound devices diagnose many disease, which is widely used, can not be standardized quantitative evaluated in order to evaluate sonography image of quality. Therefore, in this papers, aims to get correct image in order to accurate diagnosis by figuring out the appropriate parameter based on each target by measuring distortion which results in the analyzation of the sensitivity of SNR and the histogram of signal by manipulating parameter of 8 mm target in ATS-539 multipurpose phantom. Equipment using Acuson sequoia 512, convex probe and utilizes multi-objective phantom. experiment method is that first you put the phantom on the flat and acquire 85 sheets of image, changing frequency(2,3,4 MHz, harmonic 3, 4, 4.5 MHz), Focus(2, 4, 6 unit), and Dynamic Range(58, 68, 78, 88, 98) for a 8 mm structure. through the Image J program. The sensitivity angle of 8mm target through Image J program is gauged by each separate target SNR and the distorted angle subtract and measure Histogram of background from Histogram of signal and take top 40% from the given result value above. According to parameter variation we found out proper parameter by acquiring SNR of sensitivity and distortion data for aspect of transition. The more this findings have Focus, the lower distortion value and at 4 MHz frequency this result have high SNR and low distortion value. Dynamic Range got an appropriate image on 88 and 98. It is considered on the basis of the experimental data, the probability of disease diagnosis will get higher.

Analysis of Hematological Factor to Predict Plaque of the Carotid Artery in Ultrasound Images (경동맥초음파에서 죽상경화반을 예측하는 혈액학적 수치의 분석)

  • Yang, Sung Hee;Kang, Se Sik;Lee, Jinsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.187-193
    • /
    • 2016
  • In this study, we performed the carotid artery ultrasound targeting 140 subjects who have conducted to evaluate the changes in intima-media thickness(IMT) and plaque correlated with the presence or absence of a hematological test of the carotid artery. Considering that the IMT thickness more than 1mm is abnormal based on the carotid artery ultrasound to assess the presence or absence of plaque, and examined the correlation by classifying the blood lipid value and the fasting blood glucose level through the serum test. Consequently, the fasting blood glucose level is being analyzed as independent predictors of causing dental plaque(p=0.033), cut off value was determined as 126 mg/dL(sensitivity 56.25%, specificity 68.38%) in ROC curve analysis. Furthermore, the odds ratio appeared 1.01 times the value in the Logistic regression. Therefore, it seemed that the necessity to prospective studies in a number of subjects are considered, and also taking into account a number of blood test values along with the sonography of the carotid artery as a valuable part for effective primary prevention and follow-up observation of the cardiac and brain vascular disease is highly recommended.

Subluxation of the Long Head Biceps Tendon Diagnosed by Dynamic Ultrasound (동적 초음파를 이용하여 진단한 견관절 상완 이두건 장두의 아탈구)

  • Park, Sang-Eun;Jung, Jae-Jung;Lee, Yeon-Soo;Kim, Young-Yul;Kim, Myung-Jin;Ji, Jong-Hun
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.2
    • /
    • pp.236-241
    • /
    • 2011
  • Purpose: To report the usefulness of dynamic ultrasonography in subluxation of the long head of the biceps tendon, which is difficult to detect with static imaging such as plain radiography, static sonography, MRI and in a subtle physical examination. Materials and Methods: Two male patients suffered from subluxation of the long head of the biceps. This difficult diagnosis? was managed by surgery (biceps soft tissue tenodesis) with the aid of dynamic ultrasonography. At final follow up, we evaluated patients' symptoms and functional outcomes using KSS, UCLA and ASES scores. Results: We diagnosed and treated subluxation of the long head of the biceps easily using dynamic ultrasonography. At the final follow up, both patients' symptoms and functional outcomes were improved. There were no significant complications. Conclusion: Dynamic ultrasonography is a useful method in the difficult and subtle diagnosis of subluxation of the long head of the biceps.

Comparison of Supraspinatus Muscle Architecture During Three Different Shoulder Strengthening Exercises Using Ultrasonography

  • Moon, Il-young;Lim, One-bin;Cynn, Heon-seock;Yi, Chung-hwi
    • Physical Therapy Korea
    • /
    • v.23 no.2
    • /
    • pp.84-92
    • /
    • 2016
  • Background: Strengthening the supraspinatus is an important aspect of a rehabilitation program for subacromial impingement and tendinopathy. Many authors recommended empty-can (EC), full-can (FC), and prone full-can (PFC) exercises to strengthen the supraspinatus. However, no ultrasonography study has yet investigated supraspinatus muscle architecture (muscle thickness; MT, pennation angle; PA, fiber bundle length; FBL) in relation to supraspinatus strengthening exercises. Objects: The purpose of this study was to compare the architecture (MT, PA, and FBL) of the supraspinatus muscle during three different types of exercises (EC, FC, and PFC) using diagnostic ultrasound. Methods: Participants performed three different exercises: (A) EC; the arm was maintained at $60^{\circ}$ abduction with full internal rotation in the sitting position, (B) FC; the arm was maintained at $60^{\circ}$ abduction with full external rotation in the sitting position, and (C) PFC; the arm was maintained at $60^{\circ}$ abduction with full external rotation in the prone position. Ultrasonography was used to measure the MT, PA and FBL of the supraspinatus. One-way repeated analysis of variance with Bonferroni's post-hoc test was used to compare between the three exercises and the initial position of each exercise. Results: Compared with each initial position, the FC exercise showed the greatest mean difference in muscle architecture properties and the PFC exercise showed the least mean difference. Conclusion: The findings suggest that the FC exercise position may have an advantage in increasing the amount of contractile tissue or producing muscle power and the PFC exercise position may be useful in a rehabilitation program because it offers the advantage of maintaining the muscle architecture properties.

The Effects of Transverse Abdominis Ratio and Balance Ability during Bridge Exercises on Different Support Surface (지지면 변화에 따른 교각운동이 복횡근 두께와 균형능력에 미치는 영향에 관한 연구)

  • Ann, Jun-il;Kim, Yoon-hwan;Park, Jong-hang;Ann, Mi-rae;Jung, Yeon-woo;Kim, Tae-won
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effect of transverse abdominis ratio and balance ability during bridge exercises on different support surface. Methods: The subjects were 20 students at G University. Ultrasound equipment was used to measure the transverse abdominisratio and the computerized balance measurement equipment was used to measure the balance ability before and after bridge exercises on different support surface. Results: Transverse abdominis ratio change between the groups was a significant difference only in the unstable support surface training group (p<.05). Normal standing eye close balance ability change between the groups was significantly different only in the unstable support surface training group (p<.05). The changes in the transverse abdominis ratio after 7 days of exercise and 14 days after exercise were significantly different between the groups (p<.05). Normal standing eye close balance ability showed a significant difference at 7 days after exercise and 14 days after exercise (p<.05). Conclusions: It is more effective to balance ability and ratio of the transverse abdominis when bridge exercises on an unstable support surface than to perform bridge exercises on a stable support surface. Therefore, we propose an effective program for patients with instability of the lumbar in clinical practice. bridge exercises on different support surface.

  • PDF