• Title/Summary/Keyword: Ultrasound measure

Search Result 152, Processing Time 0.024 seconds

Design of a Croos-obstacle Neural network Controller using running error calibration (주행 오차 보정을 통한 장애물 극복 신경망 제어기 설계)

  • Lim, Shin-Teak;Li, BiFu;Chong, Kil-Do
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.372-374
    • /
    • 2009
  • In this research, an obstacle avoidance method is proposed. The common usage of a robot is indoor and the obstacles to the indoor robot is studied. The accurate detection of direction after overcoming the obstacles is necessary for performance of autonomous navigation and mission project. The sensors such as Laser, Ultrasound, PSD can be used to measure the obstacles. In this research, a PSD sensor is used to detect obstacles. It detects the height and width of obstacles located on the floor. Before measuring the obstacles, a calibration of the sensor was done and it produced a better accuracy. We have plotted an error graph using data obtained from the repeated experiments. The graph is fitted to a polynomial curve. The polynomial equation is used for the robot navigation. And in this research, a model of the error of the direction of the robot after overcoming obstacles was obtained also. The prototype of the obstacle and the error of the direction after overcoming the obstacles are modelled using a neural networks. The input of the neural network composed with the height of the obstacles, the speed of robot, the direction of wheels and the error of the direction. To implement the suggested algorithm, we set up a robot which is operated by a notebook computer. Experiment showed the suggested algorithm performed well.

  • PDF

Application of PET in Breast Cancer (유방암에서 PET의 응용)

  • Noh, Dong-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.34-38
    • /
    • 2002
  • Positron emission tomography(PET) is an imaging method that employs radionuclide and tomography techniques. Since 1995, we applied PET not only to the diagnosis of breast cancer but also to the detection of abnormalities in the augmented breast and to the detection of metastasis. Until 2001, we evaluated 242 breast cases by PET at PET center of Seoul National University Hospital. Our group has reported serially at the international journals. In the first report, PET showed high sensitivity for detecting breast cancer, both the primary and axillary node metastasis. A total of 27 patients underwent breast operations based on PET results at Seoul National University Hospital from 1995 to 1996. The diagnostic accuracy of PET were 97% for the primary tumor mass and 96% for axillary lymph node metastasis. In case of the breast augmented, PET also showed excellent diagnostic results for primary breast cancer and axillary lymph node metastasis where mammography and ultrasound could not diagnose properly. PET also had outstanding results in the detection of recurrent or metastatic breast cancer(sensitivity 94%, specificity 80%, accuracy 89%). In addition, our study gave some evidence that PET could be applied further to evaluate the growth rate of tumors by measuring SUV, and finally to prognosticated the disease. PET could also be applied to evaluate the response after chemotherapy to measure its metabolic rate and size. In conclsion, PET is a highly sensitive, accurate diagnostic tool for breast cancer of primary lesion in various conditions including metastasis.

Influence of Applying Loads on Subacromial Space Interval during Shoulder Abduction in Young Men (젊은 남성에서 부하 적용이 어깨 벌림 동안 봉우리밑 공간 간격에 미치는 영향)

  • Park, Kanghui;Park, Hankyu;Park, Sookyoung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.1
    • /
    • pp.169-175
    • /
    • 2020
  • Purpose : This study was performed to comparison of distance change of subacromial space according to shoulder abduction angle in loaded and unloaded conditions. Methods : The subjects were 20 male college students, and the subacromial space was measured using an ultrasound diagnostic apparatus. The participants shoulder abduction was measured during each shoulder resting position and 45 ° abduction with loads of 1 kg, 2 kg, 3 kg. The collected data were analyzed by a paired t-test and repeated measure ANOVA with the SPSS (Ver. 22) program. Results : The subacromial space showed statistically significant decreased in 45 ° abduction than resting position (p<.001). All the subacromial space increased during the according to loads (1 kg, 2 kg, 3 kg) at the resting position but at 45 ° abduction showed statistically significant decreased as the load increases (p<.05). Also, subacromial space showed significant changes in the 2kg, 3kg compared with the 0kg loads. Conclusion : These results identified that shoulder abduction angle and load were related to subacromial space. When resting position, subacromial space is larger at loads than unload. As the load and shoulder abduction angle increase, subacromial space is reduced compared to resting.

The Evaluation Technique of Surface Region using Backward-Radiated Ultrasound (후방 복사된 초음파를 이용한 표면 지역의 평가 기술)

  • Kwon, S.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.4
    • /
    • pp.241-250
    • /
    • 1997
  • The velocity dispersion of surface acoustical wave(SAW) of Si layer/mesh Au/Si substrate was measured by the frequency analysis technique of backward radiation at liquid/solid interface. The difference of backward radiation patterns depending on used transducers (2, 5, 10MHz) confirmed that the backward radiation phenomenon was caused by the energy radiation from SAW generated in surface region. An ultrasonic goniometer was constructed to measure continuously the angular dependence of backscattered intensity. The angular dependences of backward radiation(5MHz) were measured for Ni layer/Al substrate specimens that were bonded by epoxy involving different content of Cu powder. It was known that the width and pattern of backward radiation had informations such as the velocity dispersion, bonding quality and structure of surface region.

  • PDF

Equivocal Association of RAD51 Polymorphisms with Risk of Esophageal Squamous Cell Carcinoma in a Chinese Population

  • Zhang, Shu-Xiang;Yang, Shan;Xu, Chang-Qing;Hou, Rui-Ping;Zhang, Chuan-Zhen;Xu, Cui-Ping
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.763-767
    • /
    • 2014
  • Aim: To study the contribution of genetic variation in RAD51 to risk of esophageal squamous cell carcinoma (ESCC). Methods: Three single nucleotide polymorphisms (SNPs) in RAD51 (rs1801320, rs4144242 and rs4417527) were genotyped in 316 ESCC patients and 316 healthy controls in Anyang area of China using PCR-RFLP (polymerase chain reaction-restriction fragment length polymorphism). Demographic variables between cases and controls were statistically compared by T test and Chi-square test. Hardy-Weinberg equilibrium was evaluated by the Chi-square test. Odds ratios (ORs) and 95% confidence intervals (CIs) were calculated to measure any association with ESCC. Haplotype frequencies were estimated by Phase 2.1. Result: The genotype frequencies of rs1801320, rs4144242 and rs4417527 in patients with ESCC demonstrated no significant differences from those in control group (P>0.05). When the haplotypes of these three SNPs were constructed and their relationships with ESCC risk investigated, however, CGG was observed to increase the risk (P=0.020, OR=2.289). Conclusions: There was no association between the three SNPs of RAD51 and ESCC susceptibility in our Chinese population. However, the CGG haplotype might be a risk factor.

The Study of Asymmetrical of the Serratus Anterior and Lower Trapezius Muscles in Chronic Stroke Patients (만성 뇌졸중 환자의 앞 톱니근과 하부 등세모근의 비대칭성 연구)

  • Jeong, Ju-Ri;Lee, Wan-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.4
    • /
    • pp.81-90
    • /
    • 2015
  • PURPOSE: The purpose of this study was to compare the muscle architecture of serratus anterior and lower trapezius using rehabilitative ultrasound imaging (RUSI) in affected and unaffected side of chronic stroke patients. METHODS: The participants were thirty five patients with stroke hemiplegia in this study. RUSI was used to measure the muscle thickness of the serratus anterior and lower trapezius muscles. We compared the muscle thickness according to affected side and sex, determined the reliability of the measurement image. Independent t-test, intra-class correlation coefficient (ICC) and standard error of measurement (SEM) were used for statistical analysis. RESULTS: Significant difference in muscle thickness of serratus anterior was observed between affected and unaffected side (p<.001). Muscle thickness according to gender showed a significant difference in unaffected side of serratus anterior (p<.05). Compare asymmetry ratio of serratus anterior and lower trapezius muscle thickness showed a significant difference (p<.001). ICC for intra-reliability was .944~.962 in serratus anterior and .873~.925 in lower trapezius muscle thickness, respectively. SEM was .001~.004 in serratus anterior and .002~.008 in lower trapezius muscle. CONCLUSION: This study, using RUSI, showed significant difference in muscle thickness of serratus anterior in affected and unaffected side of stroke patients. RUSI is a practical tool for measuring soft-tissue thickness in the scapular region muscle of stroke.

Location Tracking System for Container Trailer Using Ubiquitous Sensor Networks (USN를 이용한 컨테이너 트레일러 위치추적 시스템)

  • Park, Jong-Hyun;Choo, Young-Yeol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.3
    • /
    • pp.627-633
    • /
    • 2007
  • This paper describes position tracking system of a container trailer approaching to a gantry crane for loading or unloading a container into or from a ship, respectively. Proposed position tracking system informs the trailer driver of right position to stop the car under a gantry crane. To measure the location of a trailer, we used Cricket Mote modules which adopted RF and ultrasound technology. We present an elaborate method to improve position errors occurring at sensing and calculate three dimensional position by triangulation along with how to reduce location tracking interval for real-time monitoring. The location information was transmitted to a Personal Digital Assistant (PDA) periodically through Bluetooth communication for guidance of the trailer driver. In indoor and outdoor tests, position errors were less than 3 cm and location tracking interval was 0.5 second on average.

Korean Medicine Treatment Including Chuna Manual Therapy on De Quervain's tenosynovitis Two Cases Reports: Comparision by Ultrasound (추나요법을 포함한 한의학적 치료로 호전된 드퀘르벵 건초염 2예: 초음파 전후 관찰 비교)

  • Bae, Jun-hyeong;Lee, Sung Joon;Byun, Sang Hyun;Ahn, Hae In;Kim, Namkwenm
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.31 no.4
    • /
    • pp.211-219
    • /
    • 2021
  • This study reports the effectiveness of Korean medicine and Chuna manual therapy on patients with De Quervain's tenosynovitis. Two patients were treated with Chuna manual therapy, electro-acupuncture, moxibustion therapy. We used numeric rating scale (NRS), Finkelstein's test, sonography to measure changes during treatment. After each treatment, NRS, Finkelstein's test, sonography outcome were improved. Korean medicine including Chuna manual therapy can be effectively used to improve De Quervain's tenosynovitis. This study may suggest that korean medicine including Chuna manual therapy can be effective for De Quervain's tenosynovitis.

Multifidus Thickness Comparison between the Effectiveness of Abdominal Bracing and Maximum Expiration Maneuvers in Lumbo-Pelvic Upright Sitting Posture

  • Ko, Minjoo;Kim, Sujung
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.4
    • /
    • pp.2178-2183
    • /
    • 2020
  • Background: Trunk flexor-extensor muscles' co-activation and upright posture are important for spinal stability. Abdominal bracing and maximal expiration are being used as exercises to excel torso co-contraction. However, no study has on comparison of the effect of this exercise on multifidus in the upright sitting posture. Objectives: This study aims to verify the effectiveness of abdominal bracing and expiration maneuvers in lumbo-pelvic upright sitting. Design: Cross-sectional study. Methods: Eighteen healthy women were recruited for this study. The multifidus muscle thickness of all subjects was measured in three sitting conditions (lumbo-pelvic upright sitting, lumbo-pelvic upright sitting with abdominal bracing, and lumbo-pelvic upright sitting with maximum expiration) using ultrasound. One-way repeated measure analysis of variance was used for the evaluation. Results: Compared to lumbo-pelvic upright sitting, lumbo-pelvic upright sitting with abdominal bracing and lumbo-pelvic upright sitting with maximum expiration were associated with significantly increment of muscle thickness. There was no significant difference in muscle thickness between lumbo-pelvic upright sitting with abdominal bracing and lumbo-pelvic upright sitting with maximum expiration. Conclusion: Abdominal bracing and maximum expiration could be beneficial to increasing lumbar multifidus thickness in lumbo-pelvic upright sitting.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF