• Title/Summary/Keyword: Ultrasound imaging technique

Search Result 85, Processing Time 0.025 seconds

Practical Approach of Laryngeal Ultrasonography (후두초음파의 임상적 활용)

  • Cho, Woojin
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.29 no.1
    • /
    • pp.19-23
    • /
    • 2018
  • Ultrasonography has increasingly moved from being a modality confined to the radiology department to an active diagnostic and therapeutic aid available to the head and neck at the point of patient care. However, the application of ultrasonography to the laryngeal disorder is very rare due to progressive age-related ossification of laryngeal cartilage and the presence of air in the lumen, which contribute to difficult conditions for transmission of the ultrasonic waves. The observation about the movements of larynx or surrounding structures is important to understand the physiology of phonation or swallowing and to diagnose the disease. Ultrasonography is a noninvasive and safe imaging technique that can be used to investigate the anatomic structures of the head and neck. Recently, the development of high-frequency ultrasonography makes it possible to apply the ultrasound in the evaluation of larynx.

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: II. Linear Wave Front Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : II. 선형파면 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.403-414
    • /
    • 2004
  • In the accompanying paper, we proposed a real. time volumetric imaging method using a cross array based on receive dynamic focusing and synthetic aperture focusing along lateral and elevational directions, respetively. But synthetic aperture methods using spherical waves are subject to beam spreading with increasing depth due to the wave diffraction phenomenon. Moreover, since the proposed method uses only one element for each transmission, it has a limited transmit power. To overcome these limitations, we propose a new real. time volumetric imaging method using cross arrays based on synthetic aperture technique with linear wave fronts. In the proposed method, linear wave fronts having different angles on the horizontal plane is transmitted successively from all transmit array elements. On receive, by employing the conventional dynamic focusing and synthetic aperture methods along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. Mathematical analysis and computer simulation results show that the proposed method can provide uniform elevational resolution over a large depth of field. Especially, since the new method can construct a volume image with a limited number of transmit receive events using a full transmit aperture, it is suitable for real-time 3D imaging with high transmit power and volume rate.

Automated Versus Handheld Breast Ultrasound for Evaluating Axillary Lymph Nodes in Patients With Breast Cancer

  • Sun Mi Kim;Mijung Jang;Bo La Yun;Sung Ui Shin;Jiwon Rim;Eunyoung Kang;Eun-Kyu Kim;Hee-Chul Shin;So Yeon Park;Bohyoung Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Objective: Automated breast ultrasound (ABUS) is a relevant imaging technique for early breast cancer diagnosis and is increasingly being used as a supplementary tool for mammography. This study compared the performance of ABUS and handheld ultrasound (HHUS) in detecting and characterizing the axillary lymph nodes (LNs) in patients with breast cancer. Materials and Methods: We retrospectively reviewed the medical records of women with recently diagnosed early breast cancer (≤ T2) who underwent both ABUS and HHUS examinations for axilla (September 2017-May 2018). ABUS and HHUS findings were compared using pathological outcomes as reference standards. Diagnostic performance in predicting any axillary LN metastasis and heavy nodal-burden metastases (i.e., ≥ 3 LNs) was evaluated. The ABUS-HHUS agreement for visibility and US findings was calculated. Results: The study included 377 women (53.1 ± 11.1 years). Among 385 breast cancers in 377 patients, 101 had axillary LN metastases and 30 had heavy nodal burden metastases. ABUS identified benign-looking or suspicious axillary LNs (average, 1.4 ± 0.8) in 246 axillae (63.9%, 246/385). According to the per-breast analysis, the sensitivity, specificity, positive and negative predictive values, and accuracy of ABUS in predicting axillary LN metastases were 43.6% (44/101), 95.1% (270/284), 75.9% (44/58), 82.6% (270/327), and 81.6% (314/385), respectively. The corresponding results for HHUS were 41.6% (42/101), 95.1% (270/284), 75.0% (42/56), 82.1% (270/329), and 81.0% (312/385), respectively, which were not significantly different from those of ABUS (P ≥ 0.53). The performance results for heavy nodal-burden metastases were 70.0% (21/30), 89.6% (318/355), 36.2% (21/58), 97.3% (318/327), and 88.1% (339/385), respectively, for ABUS and 66.7% (20/30), 89.9% (319/355), 35.7% (20/56), 97.0% (319/329), and 88.1% (339/385), respectively, for HHUS, also not showing significant difference (P ≥ 0.57). The ABUS-HHUS agreement was 95.9% (236/246; Cohen's kappa = 0.883). Conclusion: Although ABUS showed limited sensitivity in diagnosing axillary LN metastasis in early breast cancer, it was still useful as the performance was comparable to that of HHUS.

A Parametric Image Enhancement Technique for Contrast-Enhanced Ultrasonography (조영증강 의료 초음파 진단에서 파라미터 영상의 개선 기법)

  • Kim, Ho Joon;Gwak, Seong Hoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.6
    • /
    • pp.231-236
    • /
    • 2014
  • The transit time of contrast agents and the parameters of time-intensity curves in ultrasonography are important factors to diagnose various diseases of a digestive organ. We have implemented an automatic parametric imaging method to overcome the difficulty of the diagnosis by naked eyes. However, the micro-bubble noise and the respiratory motions may degrade the reliability of the parameter images. In this paper, we introduce an optimization technique based on MRF(Markov Random Field) model to enhance the quality of the parameter images, and present an image tracking algorithm to compensate the image distortion by respiratory motions. A method to extract the respiration periods from the ultrasound image sequence has been developed. We have implemented the ROI(Region of Interest) tracking algorithm using the dynamic weights and a momentum factor based on these periods. An energy function is defined for the Gibbs sampler of the image enhancement method. Through the experiments using the data to diagnose liver lesions, we have shown that the proposed method improves the quality of the parametric images.

Use of office-based ultrasonography for soft tissue lesions : A report of 3 cases with literature review (안면부 연조직 진단에서 외래기반 초음파의 사용 : 증례 보고(3례) 및 문헌 고찰)

  • Kim, Jae-Young;Kim, Min-Kyu;Lee, Sung-Hwa;Kim, Hyung Jun;Nam, Woong
    • The Journal of the Korean dental association
    • /
    • v.53 no.2
    • /
    • pp.143-152
    • /
    • 2015
  • Ultrasonography is relatively inexpensive, non-invasive imaging tool and provides real-time imaging. In addition, the images can be obtained repeatedly. But it is not widely used by dentists because it is hard to interpret and technique sensitive. Above all, ultrasonography cannot be used for hard tissue diagnosis. However, ultrasonography can be applied for diagnosis of infection, soft tissue tumor and inflammatory muscle diseases which are commonly found in dental outpatients. Generally, it shows well-defined border, hypoechoic and homogenous structure in case of benign tumor. Malignant tumor appears relatively irregular margin and heterogenous structure. Cyst represents relatively echo-free features compared with benign tumor. Although the general characteristics of abscess are similar with benign tumor, we can observe an increased vascularity and different clinical features. The purpose of this report is to present 3 cases of US images using office-based ultrasonography with their features and discuss the role of office-based ultrasound in dentistry for diagnosis of soft tissue lesions with literature review.

Diagnostic Performance of Breast MRI in the Evaluation of Contralateral Breast in Patients with Diagnosed Breast Cancer

  • Saeed, Shaista Afzal;Masroor, Imrana;Beg, Madiha;Idrees, Romana
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7607-7612
    • /
    • 2015
  • Aims: The purpose of our study was to evaluate the diagnostic performance of breast magnetic resonance imaging (MRI) in the evaluation of contralateral breast in patients with diagnosed breast cancer. A secondary objective was to determine accuracy of breast MRI in diagnosing multi-focal and multicentric lesions in the ipsilateral breast. Materials and Methods: Using a non-probability convenience sampling technique, patients with histopathologically diagnosed breast cancer with MRI of breast performed to exclude additional lesions were included. MRI findings were correlated with histopathology. In addition, follow-up imaging with mammography and ultrasound was also assessed for establishing stability of negative findings and for the detected of benign lesions. Results: Out of 157 MRI breast conducted during the period of 2008 to 2013, 49 were performed for patients with diagnosed breast cancer. The sample comprised of all females with mean age $50.7{\pm}11.0years$. The patient follow-up imaging was available for a period of 2-5 years. The sensitivity, specificity, and positive and negative predictive values of MRI in the detection of multifocal/multicenteric lesions was 85.7%, 88.8%, 60% and 96.6% respectively and for the detection of lesions in the contralateral breast were 100%, 97%, 83.3% and 100% respectively. Conclusions: Our study highlights the diagnostic performance and the added value of MRI in the detection of multifocal/multicenteric and contralateral malignant lesions. In patients with diagnosed breast cancer having dense breast parenchyma and with infiltrating lobular carcinoma as the index lesion MRI is particularly useful with excellent negative predictive value in the exclusion of additional malignant foci in the ipsilateral and contralateral breasts.

A simple calculation for the preoperative estimation of transverse rectus abdominis myocutaneous free flap volume in 2-stage breast reconstruction using a tissue expander

  • Kono, Hikaru;Ishii, Naohiro;Takayama, Masayoshi;Takemaru, Masashi;Kishi, Kazuo
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.333-339
    • /
    • 2018
  • Background Flap volume is an important factor for obtaining satisfactory symmetry in breast reconstruction with a transverse rectus abdominis myocutaneous (TRAM) free flap. We aimed to develop an easy and simple method to estimate flap volume. Methods We performed a preoperative estimation of the TRAM flap volume in five patients with breast cancer who underwent 2-stage breast reconstruction following an immediate tissue expander operation after a simple mastectomy. We measured the height and width of each flap zone using a ruler and measured the tissue thickness by ultrasound. The volume of each zone, approximated as a triangular or square prism, was then calculated. The zone volumes were summed to obtain the total calculated volume of the TRAM flap. We then determined the width of zone II, so that the calculated flap volume was equal to the required flap volume ($1.2{\times}1.05{\times}$the weight of the resected mastectomy tissue). The TRAM flap was transferred vertically so that zone III was located on the upper side, and zone II was trimmed in the sitting position after vascular anastomosis. We compared the estimated flap width of zone II (=X) with the actual flap width of zone II. Results X was similar to the actual measured width. Accurate volume replacement with the TRAM flap resulted in good symmetry in all cases. Conclusions The volume of a free TRAM flap can be straightforwardly estimated preoperatively using the method presented here, with ultrasound, ruler, and simple calculations, and this technique may help reduced the time required for precise flap tailoring.

Diagnostic Consistency between Sonoelastography and Conventional Sonography of Long Head of the Biceps

  • Yoon, Sunghyun;Seo, Joong-Bae;Yoo, Jae-Sung;Ryu, Jee-Won
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.3
    • /
    • pp.107-113
    • /
    • 2014
  • Background: Sonoelastography (SE) is a new technique that can assess differences in tissue stiffness, the purpose of this study was to evaluate the ability of SE to assess the long head of biceps tendon alteration. Methods: Forty shoulders of 36 consecutively registered patients with clinical symptoms and conventional ultrasonography findings of biceps tendinitis or tendinosis, and 40 asymptomatic shoulders of 20 healthy volunteers were assessed with SE. Transverse and longitudinal images of long head of biceps tendon were obtained using SE. SE images were performed by one orthopedic surgeon and evaluated by two orthopedic surgeons using an experimentally proven color grading system. Results: The transverse images of SE showed a sensitivity of 87.5%, a specificity of 95.0% and a accuracy of 91.3%, the longitudinal images of SE showed a sensitivity of 92.5%, a specificity of 90.0% and a accuracy of 91.3%. Inter-observer reliability of SE was in 'almost perfect agreement' with a weighted kappa coefficient of 0.83. Conclusions: SE is valuable in the detection of the intratendinous and peritendinous alterations of biceps tendon, and has excellent accuracy and excellent correlation with conventional ultrasound findings.

Air-coupled ultrasonic tomography of solids: 1 Fundamental development

  • Hall, Kerry S.;Popovics, John S.
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.17-29
    • /
    • 2016
  • Ultrasonic tomography is a powerful tool for identifying defects within an object or structure. But practical application of ultrasonic tomography to solids is often limited by time consuming transducer coupling. Air-coupled ultrasonic measurements may eliminate the coupling problem and allow for more rapid data collection and tomographic image construction. This research aims to integrate recent developments in air-coupled ultrasonic measurements with current tomography reconstruction routines to improve testing capability. The goal is to identify low velocity inclusions (air-filled voids and notches) within solids using constructed velocity images. Finite element analysis is used to simulate the experiment in order to determine efficient data collection schemes. Comparable air-coupled ultrasonic signals are then collected through homogeneous and isotropic solid (PVC polymer) samples. Volumetric (void) and planar (notch) inclusions within the samples are identified in the constructed velocity tomograms for a variety of transducer configurations. Although there is some distortion of the inclusions, the experimentally obtained tomograms accurately indicate their size and location. Reconstruction error values, defined as misidentification of the inclusion size and position, were in the range of 1.5-1.7%. Part 2 of this paper set will describe the application of this imaging technique to concrete that contains inclusions.

Diagnostic Imaging for Solitary Nodular Form of Alimentary Lymphoma in a Dog (개 고립 결절 형태의 소화기계 림프종에 대한 진단영상 1례)

  • Choi, Ji-Hye;Kim, Hyun-Wook;Jang, Jae-Young;Kim, Hye-Jin;Kim, Jun-Young;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.467-472
    • /
    • 2007
  • Alimentary lymphoma accounts for approximately 5% of neoplasm and diffuse lesion is more common than solitary nodular form in dogs. An eleven year-old male Yorkshire terrier was examined because of nonspecific gastrointestinal symptoms such as anorexia and vomiting for 10 days. An abdominal mass was palpated, which was originated from small intestinal wall in abdominal ultrasonography. Small intestine was obstructed by hypoechoic mass and lost normal layering and measured 24.5m. After fine-needle aspiration, septic peritonitis due to intestinal rupture occurred and emergency surgery was performed. Solitary mass was found in small intestine and diagnosed as alimentary lymphoma through histopathologic examination. Conclusively, abdominal ultrasonouaphy could verify the thickened bowel, loss of wall layering and decrease of motility and percutaneous ultrasound-guided fine-needle aspiration is considered as useful diagnostic technique, especially in nodular form of alimentary lymphoma.