• 제목/요약/키워드: Ultrasound Test

검색결과 399건 처리시간 0.023초

Intestinal Lymphoma in a Halla Horse

  • Jeong, Hyohoon;Lee, Seyoung;Park, Kyung-won;Lee, Eun-bee;Kim, Jae-Hoon;Jung, Ji-Youl;Seo, Jong-pil
    • 한국임상수의학회지
    • /
    • 제39권3호
    • /
    • pp.138-143
    • /
    • 2022
  • A 21-year-old female Halla Horse weighing 248 kg was referred to the Jeju National University Equine Hospital with the chief complaint of anorexia accompanied by general weakness and depression for the previous three days suspected to be related to colic. Extensive diagnostic tests were performed for the following six days, including complete blood count (CBC), serum chemistry, gastroscopy, x-rays, and ultrasound imaging. The signalment, history, symptoms, and test results strongly suggested a chronic intestinal inflammatory disease with or without an alimentary tumor; hence, an exploratory laparotomy was performed. Almost the entire small intestine wall was severely thickened with diffuse ecchymosis on the serosa and protruded nodules on the mucosa. A presumptive diagnosis of an intestinal tumor was made, and the patient was euthanized, considering the patient's welfare with poor prognosis and low expectancy. A massive part of the small intestine was collected and submitted for macroscopic and microscopic pathology evaluations. The pathologic examination, including immunohistochemistry (IHC), indicated equine intestinal lymphoma showing strong positivity for T cell marker. This report describes the clinical signs, diagnosis and pathological features of intestinal lymphoma in a Halla Horse in detail.

Acoustic Estimation of Phase Velocity of Closed-Cell Kelvin Structure based on Spectral Phase Analysis

  • Kim, Nohyu
    • International Journal of Advanced Culture Technology
    • /
    • 제10권3호
    • /
    • pp.339-345
    • /
    • 2022
  • In this paper, the effect of porosity on the acoustic phase velocity of the 3D printed Kelvin closed-cell structure was investigated using the spectral phase analysis. Since Kelvin cells bring about the large amount of scattering, acoustic pulses in ultrasonic measurements undergoes a distortion of waveforms due to the dispersion effect. In order to take account on the dispersion, mathematical expressions for calculating the phase velocity of longitudinal waves propagating normal to the plane of the Kelvin structure are suggested by introducing a complex wave number based on Fourier transform. 3D Kelvin structure composed of identical unit-cells, a polyhedron of 14 faces with 6 quadrilateral and 8 hexagonal faces, was developed and fabricated by 3D CAD and 3D printer to represent the micro-structure of porous materials such as aluminum foam and cancellous bone. Total nine samples of 3D Kelvin structure with different porosity were made by changing the thickness of polyhedron. Ultrasonic pulse of 1MHz center frequency was applied to the Kelvin structures for the measurement of the phase velocity of ultrasound using the TOF(time-of-flight) and the phase spectral method. From the experimental results, it was found that the acoustic phase velocity decreased linearly with the porosity.

Development of a multi-modal imaging system for single-gamma and fluorescence fusion images

  • Young Been Han;Seong Jong Hong;Ho-Young Lee;Seong Hyun Song
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3844-3853
    • /
    • 2023
  • Although radiation and chemotherapy methods for cancer therapy have advanced significantly, surgical resection is still recommended for most cancers. Therefore, intraoperative imaging studies have emerged as a surgical tool for identifying tumor margins. Intraoperative imaging has been examined using conventional imaging devices, such as optical near-infrared probes, gamma probes, and ultrasound devices. However, each modality has its limitations, such as depth penetration and spatial resolution. To overcome these limitations, hybrid imaging modalities and tracer studies are being developed. In a previous study, a multi-modal laparoscope with silicon photo-multiplier (SiPM)-based gamma detection acquired a 1 s interval gamma image. However, improvements in the near-infrared fluorophore (NIRF) signal intensity and gamma image central defects are needed to further evaluate the usefulness of multi-modal systems. In this study, an attempt was made to change the NIRF image acquisition method and the SiPM-based gamma detector to improve the source detection ability and reduce the image acquisition time. The performance of the multi-modal system using a complementary metal oxide semiconductor and modified SiPM gamma detector was evaluated in a phantom test. In future studies, a multi-modal system will be further optimized for pilot preclinical studies.

수중 MIMO 벡터 채널 모델링 및 성능 분석 (MIMO Vector Channel Modeling and Performance Analysis in Underwater Channel Environments)

  • 이덕환;고학림;임용곤
    • 한국음향학회지
    • /
    • 제26권8호
    • /
    • pp.426-431
    • /
    • 2007
  • 본 논문에서는 수중 채널 환경에서 초음파 통신의 성능 및 효율을 향상시키기 위하여 MIMO(Multiple Input Multiple Output) 용 수중 벡터 채널 모델링을 연구하였으며, 이를 이용한 MIMO 기법의 성능을 분석하였다. 수중 MIMO 채널 모델링을 위하여 실해역 환경에서 측정을 수행하였으며, 측정된 데이터를 분석하여 수중 채널 환경에서의 페이딩, 도플러, 시간지연, 도달각, 수신전력 등의 파라미터 값을 추정하였고, 이를 이용한 MIMO용 수중 벡터 채널 모델링을 수행하였다. 또한 제안된 채널 모델링을 이용하여 수중 MIMO 시스템의 성능을 분석하였으며, 성능 분석 결과 수중에서 MIMO 기법을 사용하는 경우 같은 SNR에 대해 비트 에러 율이 크게 감소함을 알 수 있었다.

대기 중 이산화질소의 단기 측정을 위한 뱃지형 passive sampler의 개발 및 평가 (Development and Evaluation of a Badge-type Passive Sampler for the Measurement of Short-term Nitrogen Dioxide in Ambient Air)

  • 김선규;임봉빈;정의석;김선태
    • 한국대기환경학회지
    • /
    • 제22권1호
    • /
    • pp.117-126
    • /
    • 2006
  • The purpose of this study is to develop a badge-type passive sampler for the measurement of short-term nitrogen dioxide and to evaluate its performance. The principle of the method is a colorimetric reaction of nitrogen dioxide with sulfanilic acid, N-1-naphthylethylendiamine, and phosphoric acid. First, it has been shown that the filter paper should be rinsed with ultrapure water and ultrasound, and then dried in a vacuumed desiccator. The concentration and volume of absorption reagent (triethanolamine) were $20\%$ and 100 ${\mu}L$, respectively. The extraction time was determined as 60 min. Second, duplicate measurements (n= 116) were carried out for evaluating the precision of the passive sampler. The relative error and the correlation coefficient between duplicates are $3.4\pm 3.0\%$ and 0.994, respectively. In addition, the $95\%$ confidence interval of intraclass correlation coefficient and the estimated value are 0.992$\sim$0.996 and 0.994, respectively. Third, a paired t-test was carried out for evaluating the accuracy of the passive sampler (n=40). In the result of the test, the $95\%$ confidence interval of the difference was -1.710 ppb <$\gamma$< 0.788 ppb. Finally, the average concentration of blanks, measurement detection limit, limit of detection, and limit of quantification are $2.4\pm 0.4$ ppb, 104 ppb, 3.8 ppb, and 7.0 ppb, respectively.

분만방법 유형이 골반바닥근육 기능에 미치는 영향 (Effects of Pelvic Floor Muscle Function on Mode of Delivery)

  • 권유정;이현옥
    • PNF and Movement
    • /
    • 제15권3호
    • /
    • pp.373-380
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate of the effects of the mode of delivery on pelvic floor muscle function by examining bladder base movement and urinary incontinence. Methods: This study was conducted on 100 females who had delivered in the previous 3-8 months. There were 2 groups: 56 vaginal deliveries and 44 cesarean section deliveries. Prior to the study, a survey was conducted on the subjects' general status, delivery mode, urinary incontinence, and physical activity. The groups could not be blinded due to scar tissue from the operations. The function of the pelvic floor muscle was observed with the bladder base movement using transabdominal ultrasound during pelvic floor contraction. To objectify and measure the subjective symptoms of subjects suffering from urinary incontinence, an incontinence quality of life (I-QoL) test was administered. Statistical analysis of the data was performed using SPSS version 20.0. An independent t-test was used to assess the statistical significance of pelvic floor muscle function between the 2 groups after delivery. Results: The movement of the bladder base in the pelvic floor muscle function was decreased in the vaginal delivery group, but the difference was not significant. Urinary incontinence was significantly increased in the vaginal delivery group. Conclusion: The function of the pelvic floor muscles was better in the cesarean section group and the incidence of urinary incontinence was relatively low in this group. Therefore, vaginal delivery requires more efforts to restore the function of the pelvic floor muscles than cesarean delivery.

1차원 배열 탐촉자의 방사빔추적기법을 이용한 정적 3차원 초음파진단영상 구성 (Construction of Static 3D Ultrasonography Image by Radiation Beam Tracking Method from 1D Array Probe)

  • 김용태;도일;안봉영;김광연
    • 비파괴검사학회지
    • /
    • 제35권2호
    • /
    • pp.128-133
    • /
    • 2015
  • 원격진료를 요하는 응급현장에서 사용을 위하여 1차원 배열 탐촉자를 손으로 조작하는 동안 변하는 방사빔의 위치를 추적하여 정적인 3차원 초음파영상을 구성하였다. 탐촉자에 고정된 모션센서의 병진운동 및 회전운동에 대한 정보를 기준직교좌표계로 변환하는 이론적 모델을 제시하였으며, 신호 증폭과 시리얼 통신을 위한 인터페이스 용도의 모듈을 상용의 센서를 사용하여 제작하였다. 실리콘 퍼티로 제작된 시험용 팬텀에 대한 B-모드의 동영상과 센서의 신호를 동기화하여 기록하였다. 동영상으로부터 주기적으로 추출한 B-모드 영상과 각 영상내의 픽셀 각각의 그레이 레벨을 이용하여 3차원 복셀의 그레이 레벨을 재구성하였다. 이 복셀의 데이터를 이용하여 3차원 영상과 임의단면의 B-모드 방식의 2차원 영상을 구성하였으며, 이 영상들은 시험용 팬텀의 형상과 잘 일치하였다.

간헐적 양압호흡기를 이용한 호흡운동치료 후 근 이영양증 환자의 폐기능 변화 (Changes in Pulmonary Functioning After Respiratory Excercise Treatment in Patients With Progressive Muscular Dystrophy)

  • 김기송;이규완;오덕원
    • 한국전문물리치료학회지
    • /
    • 제6권3호
    • /
    • pp.72-81
    • /
    • 1999
  • The purpose of this study was to identify the differences in pulmonary functioning after respiratory exercise with IPPB (Intermittent Positive Pressure Breather) in patients with progressive muscular dystrophy (PMD). The subjects were 46 patients with PMD who were admitted to the Rehabilitation Medicine Department of Youngdong Severance Hospital. The subjects were assigned into one of 2 groups. The control group received comprehensive treatments such as ROM exercise, deep breathing exercise, moist hot packs, and ultrasound twice a day while admitted at the Rehabilitation Medicine Department. Unlike the control group, the subjects at the experimental group received respiratory exercise treatment with IPPB. The subjects were admitted for 10~19 days, and the average length of hospital stay was 12.2 days. Pulmonary functioning was evaluated at admission and discharge by SENSOR MEDICS. The data were analyzed by a paired t-test and a independent t-test. The results were as follows: 1) The change of each parameter of pulmonary function tests were significantly improved in all groups after respiratory exercise treatment during admission (p<0.05). 2) By comparing the change of each parameter of pulmonary function tests between the experimental group and control group, the parameters of vital capacity (VC), forced vital capacity, forced vital capacity predicted (FVCP) and forced expiratory volume in 1 second (FEV1) were significantly improved in the experimental group which had received the pulmonary exercise treatment with IPPB (p<0.05). In conclusion, this study suggests that the pulmonary exercise treatments with IPPB facilitated improvement in the pulmonary functioning for the PMD patients during their hospital stay.

  • PDF

Ultrasonic Characterization on Sequences of CFRP Composites Based on Modeling and Motorized System

  • Im, Kwang-Hee;David K. Hsu;Song, Sung-Jin;Park, Je-Woung;Sim, Jae-Ki;Yang, In-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제18권1호
    • /
    • pp.65-73
    • /
    • 2004
  • Composites are a material class for which nondestructive material property characterization is as important as flaw detection. Laminates of fiber reinforced composites often possess strong in-plane elastic anisotropy attributable to the specific fiber orientation and layup sequence when waves are propagating in the thickness direction of composite laminates. So the layup orientation greatly influences its properties in a composite laminate. It could result in the part being .ejected and discarded if the layup orientation of a ply is misaligned. A nondestructive technique would be very beneficial, which could be used to test the part after curing and requires less time than the optical test. Therefore a ply-by-ply vector decomposition model has been developed, simplified, and implemented for composite laminates fabricated from unidirectional plies. This model decomposes the transmission of a linearly polarized ultrasound wave into orthogonal components through each ply of a laminate. Also in order to develop these methods into practical inspection tools, motorized system have been developed for different measurement modalities for acquiring ultrasonic signals as a function of in-plane angle. It is found that high probability shows between the model and tests developed in characterizing cured layups of the laminates.

초음파영상을 이용한 정상 교근의 평가 (Evaluation of normal masseter muscles on ultrasonography)

  • 황형주;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제38권2호
    • /
    • pp.73-79
    • /
    • 2008
  • Purpose: To assess the internal echo intensity and morphological variability of masseter muscles on ultrasonography and to establish diagnostic criterion of estimation. Materials and Methods: Participants consisted of 50 young adults (male 25, female 25) without pathologic conditions and with full natural dentitions. Sonographic examinations were done with real time ultrasound equipment as Logiq 500 (GE Medical Systems, Seoul, Korea) at 3 parts according to lines paralleling with ala-tragus line as reference line. The thickness and area of masseter muscles according to reference line in cross-sectional images were measured at rest and at maximum contraction. The visibility and width of the internal echogenic intensity of the masseter muscles were also assessed and the muscle appearance was classified into 4 types. Data were statistically analyzed by paired t-test and $x^2$-test. Results: 1. When comparing the thickness and area of masseter muscles concerning with gender, there was few significant difference between right and left sides, however, there were significant differences between males and females except for the greatest thickness of left side. 2. The changes of the greatest thickness and the area between rest and maximum contraction showed that the part of the least thickness manifested more increase at maximum contraction. 3. Each part the manifestations of the internal echogenic intensity of the masseter muscles were different depending on the locations. But there was no statistically significance. Conclusion: Changes of muscles thickness with contraction and internal echogenic intensity with locations showed great disparity within the masseter muscles, which will be diagnostic criteria for pathophysiologic and anatomic changes of masseter muscles.

  • PDF