Accuracy of Pulsed Doppler Ultrasound Velocity Measurements : In Vitro Flow Phantom Study (Pulsed Doppler 초음파속도측정의 정확도 판정 : 유동 phantom 연구)

  • Kim, Young-Ho;Min, Byung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.153-156
    • /
    • 1994
  • An in vitro steady flow experiment was performed in order to test the accuracy of velocity measurement obtained through a pulsed Doppler echocardiography. A flow phantom was designed for the use in a wide velocity range at a given flow rate. The results showed that the pulsed Doppler velocity measurement obtained in this flow phantom is accurate at low flow rates. However, ultrasound velocity measurement should be performed under a careful considerations of PRF and Doppler gain settings, especially at higher flow rates.

  • PDF

Ultrasound Guided Transversus Abdominis Plane Block for Anterior Cutaneous Nerve Entrapment Syndrome

  • Sahoo, Rajendra Kumar;Nair, Abhijit S.
    • The Korean Journal of Pain
    • /
    • 제28권4호
    • /
    • pp.284-286
    • /
    • 2015
  • Anterior cutaneous nerve entrapment syndrome (ACNES) is one the most common cause of chronic abdominal wall pain. The syndrome is mostly misdiagnosed, treated wrongly and inadequately. If diagnosed correctly by history, examination and a positive carnett test, the suffering of the patient can be relieved by addressing the cause i.e. local anaesthetic with steroid injection at the entrapment site. Conventionally, the injection is done by landmark technique. In this report, we have described 2 patients who were diagnosed with ACNES who were offered ultrasound guided transverses abdominis plane (TAP) injection who got significant pain relief for a long duration of time.

Comparative Efficacy of Four Imaging Instruments for Breast Cancer Screening

  • Mehnati, Parinaz;Tirtash, Maede Jafari
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권15호
    • /
    • pp.6177-6186
    • /
    • 2015
  • Sensitivity and specificity are the two most important indicators in selection of medical imaging devices for cancer screening. Breast images taken by conventional or digital mammography, ultrasound, MRI and optical mammography were collected from 2,143,852 patients. They were then studied and compared for sensitivity and specificity results. Optical mammography had the highest sensitivity (p<0.001 and p<0.006) except with MRI. Digital mammography had the highest specificity for breast cancer imaging. A comparison of specificity between digital mammography and optical mammography was significant (p<0.021). If two or more breast diagnostic imaging tests are requested the overall sensitivity and specificity will increase. In this literature review study patients at high-risk of breast cancer were studied beside normal or sensitive women. The image modality performance of each breast test was compared for each.

The Texture Classification of Liver Parenchyma Using the Fractal Dimension and the Fourier Power Spectrum (프랙탈 차원과 퓨리에 파워스펙트럼을 이용한 간조직 분류)

  • Jeong, Jeong-Won;Kim, Dong-Youn
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.37-41
    • /
    • 1995
  • In this paper, we proposed the 2-stage ultrasound liver image classifier which uses the fractal dimensions obtained from the original image and its 1/2 subsampled image, and the Normalized Fourier Power Spectrum. The fractal dimension based on Fractional Brownian Motion (FBM) is calculated from the variance of the same scale pixels instead of the mean of them. Since the actual ultrasound. liver images does not fully match the FBM, to get the fractal dimension, we use the scale vectors which satisfy the FBM model. In 2-stage classifier, we first classified normal and diffuse liver and then classified the fat liver and cirrhosis from the diffuse liver. For the test liver images. 70% of normal liver and 80% of fat liver and 90% of cirrhosis is classified classified with our 2-stage classifier.

  • PDF

Ultrasonically Enhanced Dewaterability of Fine Particles (초미립자 탈수성 증대를 위한 초음파 활용에 관한 연구)

  • Oh, Chul;Kim, Byoung-Il;Kim, Young-Uk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.313-320
    • /
    • 2002
  • In accordance with the need of developing a methodology for the sludge reduction, this study investigates the effect of sonication on the dewaterability of the sewage sludge. The investigation involves laboratory experiments of the sewage sludge from Yongin Waste Treatment Plant. The Laboratory tests were conducted under a broad range of conditions including energy levels of ultrasonic waves, time for the treatment, pH, and effect of polymers. The results of the study show that sonication enhances the dewaterability significantly The degree of enhancement varies with sonication power, treatment time, the amount of sludge treated. The effect of sonication on the temperature and pH of the test specimens seems not to be significant. The polymer can be useful to enhance the effectiveness of ultrasound treatment.

  • PDF

Automatic Detection Method of the Region of Interest in the Measurement of Bone Mineral Density by Ultrasound Imaging (초음파 영상에 의한 골밀도 측정에서 관심영역의 자동 검출방법)

  • 신정식;안중환;한은옥;김형준;한승무
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제21권11호
    • /
    • pp.200-208
    • /
    • 2004
  • In ultrasonic bone densitometry, the positioning of measurement site is decisive in precision and reproducibility. In this study, automatic Region of Interest (ROI) detection algorithm is suggested and adopted the method using the local minimum value by ultrasonic image. The preprocess before the local minimum method extracts out the bone area and calculates the geometrical information of bone. The developed ROI detection algorithm was applied to the clinical test for the subject of 305 female patients in the range of 22-88 years old. As the results, the accuracy of the algorithm was shown to be 98.3%. It was also found that bone density parameter was significantly correlated with age(r=0.85, p<0.0001).

Performance Enhancement of Ultrasonic Sensitivity by Improving the Transmitter Circuit

  • Lee, Cheul-Won;Kim, Young-Kil
    • Journal of Biomedical Engineering Research
    • /
    • 제27권4호
    • /
    • pp.164-169
    • /
    • 2006
  • We have developed the spirometer system; many patients having weak respiration have difficulties in using conventional spirometers in hospitals, because their weak breath can be affected by the errors of inertia and instrumental pressure. We have developed a new ultrasound spirometer using an ARM 920T processor. To detect weak respiratory signals, we add a comparator circuit, which can afford more information of respiration characteristics such as respiration volume, directions, and velocities. We have also developed Gill for graphical display of respiration characteristics. Through the pilot test, it has been verified that the developed spirometer is operating reliably.

In-situ fatigue monitoring procedure using nonlinear ultrasonic surface waves considering the nonlinear effects in the measurement system

  • Dib, Gerges;Roy, Surajit;Ramuhalli, Pradeep;Chai, Jangbom
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.867-876
    • /
    • 2019
  • Second harmonic generation using nonlinear ultrasonic waves have been shown to be an early indicator of possible fatigue damage in nuclear power plant components. This technique relies on measuring amplitudes, making it highly susceptible to variations in transducer coupling and instrumentation. This paper proposes an experimental procedure for in-situ surface wave nonlinear ultrasound measurements on specimen with permanently mounted transducers under high cycle fatigue loading without interrupting the experiment. It allows continuous monitoring and minimizes variation due to transducer coupling. Moreover, relations describing the effects of the measurement system nonlinearity including the effects of the material transfer function on the measured nonlinearity parameter are derived. An in-situ high cycle fatigue test was conducted using two 304 stainless steel specimens with two different excitation frequencies. A comprehensive analysis of the nonlinear sources, which result in variations in the measured nonlinearity parameters, was performed and the effects of the system nonlinearities are explained and identified. In both specimens, monotonic trend was observed in nonlinear parameter when the value of fundamental amplitude was not changing.

Effect of Craniocervical Flexion Exercise on Pain and Cross Sectional Area of Longus Colli Muscle in Workers with Chronic Neck Pain (두경부 굴곡 운동이 만성 경부통 근로자의 통증 및 경장근 단면적에 미치는 영향)

  • Chon, Seung-Chul;Chang, Ki-Yeon
    • Journal of the Ergonomics Society of Korea
    • /
    • 제29권6호
    • /
    • pp.889-895
    • /
    • 2010
  • This study compared the effects of craniocervical flexion exercise with conservative cervical flexion exercise in workers with chronic neck pain. Subjects were randomly allocated to two groups: control (n=20) and experimental group (n=20), respectively. The conservative exercise for the control group consisted of cervical flexion exercise, whereas the experimental group performed a craniocervical flexion exercise. To compare the two groups, the visual analogue scale (VAS) for a pain, neck disability index (NDI) for a neck disability scale, and cross sectional area (CSA) of longus colli muscle using ultrasound image were assessed on pre-intervention, post-intervention, and 2 weeks follow-up. 2-way repeated ANOVA was used with Bonferroni post-hoc test. (1) There were significant main effects (within and between groups) (p<0.05) and interaction effect (p<0.05) in VAS. Post-hoc test revealed that there were significant differences in all pair-wise comparisons. (2) There were significant main effects (within and between groups) (p<0.05) and interaction effect (p<0.05) in NDI. Post-hoc test revealed that there were significant differences between pre-intervention and post-intervention, pre-intervention and 2 weeks follow-up. (3) There were significant main effects (within and between groups) (p<0.05) and interaction effect (p<0.05) in CSA of longus colli muscle. Post-hoc test revealed that there were significant differences in all pair-wise comparisons. The findings indicate that craniocervical flexion exercise are more effective for improving pain, neck disability, and CSA of longus colli muscle than cervical flexion exercise in workers with chronic neck pain.

Effects of a video education program for patients with benign uterine tumors receiving high-intensity focused ultrasound treatment (고강도 집속 초음파 치료를 받는 자궁양성종양 환자의 동영상 교육프로그램 효과)

  • Hong, Mi Suk;Park, Hyoung Sook;Cho, Young Suk
    • Women's Health Nursing
    • /
    • 제26권2호
    • /
    • pp.151-160
    • /
    • 2020
  • Purpose: The purpose of this study was to examine the effects of a video education program in women receiving high-intensity focused ultrasound (HIFU) treatment. Methods: This was a quasi-experimental study with a nonequivalent control group non-synchronized design. The participants were 54 patients who had benign uterine tumors and adenomyosis. The data were collected from June to August 2018. A 10-minute video education program on HIFU and post-procedural care was developed based on the literature. The experimental group was provided the video education program with a question-and-answer session for 10 minutes after viewing the video. The control group received usual care (i.e., verbal instructions on post-procedural self-care). The questionnaire survey was conducted twice: before the educational program and before being discharged from the hospital. Differences in uncertainty, emotions, and self-efficacy among patients were analyzed. Data were analyzed using the chi-square test, Shapiro-Wilk test, paired t-test, and t-test with SPSS version 23.0. Results: The participants in the experimental group showed a decrease in uncertainty (t=4.33, p<.001), improvements in anxiety (t=-4.07, p<.001) and depression (t=-3.55, p<.001), and an enhancement of self-efficacy (t=-4.39, p<.001) compared to the control group. Conclusion: This nursing intervention was effective at reducing uncertainty, improving emotions, and enhancing self-efficacy. This intervention is feasible for use in nursing practice as an aid for patients when considering treatment methods.