• Title/Summary/Keyword: Ultrasound Mode

Search Result 125, Processing Time 0.028 seconds

Septic Implantation Syndrome Following Anterior Lens Capsule Disruption by Cat Claw in Three Dogs (개에서 고양이 발톱에 의한 수정체 전낭 파열 후 감염체 착상 증후군의 발생 3 증례)

  • Kang, Seonmi;Lee, Euiri;Park, Sangwan;Park, Sungwon;Noh, Hyunwoo;Seo, Kangmoon
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.344-349
    • /
    • 2014
  • A 5-year-old intact female Maltese, a 4-year-old neutered male Chihuahua, and a 5-year-old neutered male Maltese were referred to Veterinary Medical Teaching Hospital of Seoul National University for assessment of traumatic corneal laceration accompanied by anterior lens capsule disruption by cat claw. Severe uveitis, hypopyon, fibrinous exudate, diffuse corneal edema, and/or glaucoma were observed. B-mode ocular ultrasound showed lens capsule rupture and hyperechoic lens in all three cases. Despite aggressive treatments, the three eyes continued to deteriorate with endophthalmitis, leading to enucleation. Septic implantation syndrome associated with phakitis, severe pyogranulomatous endophthalmitis, and keratitis was confirmed by histopathological examination.

The Effects of Breathing Retraining on Asymmetry of Diaphragm Thickness in Stroke Patients (호흡훈련이 뇌졸중 환자의 횡격막 비대칭에 미치는 영향)

  • Kim, Nan-Soo;Jung, Ju-Hyeon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.2
    • /
    • pp.263-269
    • /
    • 2013
  • PURPOSE: The purpose of this study was to examine the effects of breathing retraining on asymmetry of diaphragm thickness in stroke patients. METHODS: This study was nonequivalent control group pre-post test design. Subjects were assigned to two different groups(intervention group=10, control group=12). Intervention group conducted breathing retraining program for six-week. Diaphragm thickness was assessed by ultrasound in B-mode with a 7.5 MHz linea probe. The collected data analyzed by Wilcoxon signed rank test and Mann-Whitney U test. RESULTS: The intervention group significantly increased diaphragm thickness ratio on paretic side but the control group showed no significant difference in diaphragm thickness ratio. The control group significantly increased asymmetry of diaphragm thickness, but intervention group showed no significant difference in asymmetry of diaphragm thickness. CONCLUSION: This study showed that breathing retraining increased diaphragm thickness ratio in stroke patients and prevent the increase of asymmetry in diaphragm thickness with stroke patients.

Ultrasonic Approach of Rayleigh Pitch-catch Contact Ultrasound Waves on CFRP Laminated Composites

  • Yang, In-Young;Im, Kwang-Hee;Heo, Uk;Hsu, David K.;Sim, Jae-Ki;Kim, Hak-Joon;Song, Sung-Jin
    • Journal of Korea Foundry Society
    • /
    • v.27 no.5
    • /
    • pp.209-211
    • /
    • 2007
  • 최근에는 탄소섬유강화복합재료(CFRP)는 우수한 기계적인 물성치와 수월한 설계특성으로 인해 우주.민간 항공산업분야 뿐만 아니라 여러분야에 응용성이 매우 높다. 그러나 CFRP 복합적층판으로 제작된 구조물은 충격손상을 받을 시에는 50-75%치 강도가 낮아지는 취약성을 가지고 있다. 따라서 본 연구에는 CFRP복합재의 구조건전성 및 결함여부를 비파괴적으로 검사 및 탐상을 하기 위해서 시도하였다. 특히, C-scanner의 수침조에서 충격손상을 받은 시험편을 집어넣어 자동 데이터 획득 시스템을 구동하여 현장응용성이 가장 높은 일 방향 초음파측정 (one-sided ultrasonic measurement) 방법인 평가기법을 제안하였다. 본 연구에서 제안한 일방향 초음파 피치캐치방법이 CFRP 복합적층판내에서 일반 수직 초음파 탐상기법보다 훨씬 민감함을 알 수 있었다.

Effects of the PNF Stabilization Technique for the Hip Joint and the Bridging Exercise on the Trunk Stabilizer Muscles in Healthy Adults (고관절에 적용한 PNF 안정화 기법과 교각운동이 요부안정화 근육에 미치는 영향)

  • Kim, Yong-Hun;Jung, Ju-Hyeon
    • PNF and Movement
    • /
    • v.15 no.1
    • /
    • pp.51-56
    • /
    • 2017
  • Purpose: The purpose of this study was to examine the effects of the PNF stabilization technique for the hip joint and the bridging exercise on the trunk stabilizer muscles in healthy adults. Methods: Twenty-eight healthy adults were randomly allocated to either a PNF stabilization exercise group (n = 12) or a bridging exercise group (n = 16). The outcome measures included the contraction thickness ratio in the transversus abdominis (TrA), internal oblique (IO), and external oblique (EO), and the TrA lateral slide was assessed during the abdominal drawing-in maneuver using b-mode ultrasound. The researcher measured the abdominal muscle thickness of each participant before the therapist began the intervention and at the moment that the intervention was applied. Between-group comparisons were performed using the Mann-Whitney U test. The level of statistical significance was set at 0.05. Results: The PNF intervention program showed a significant increase in the trunk stabilizer muscle. The percentage of change in the TrA thickness showed a significant interaction between intervention. However, there were no significant differences in the IO and EO between the two groups. Conclusion: The PNF stabilization technique for the hip joint can be used effectively to improve the IO and TrA muscles in healthy adults.

M-mode Ultrasound Assessment of Diaphragmatic Excursions in Chronic Obstructive Pulmonary Disease : Relation to Pulmonary Function Test and Mouth Pressure (만성폐쇄성 폐질환 환자에서 M-mode 초음파로 측정한 횡격막 운동)

  • Lim, Sung-Chul;Jang, Il-Gweon;Park, Hyeong-Kwan;Hwang, Jun-Hwa;Kang, Yu-Ho;Kim, Young-Chul;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.736-745
    • /
    • 1998
  • Background: Respiratory muscle interaction is further profoundly affected by a number of pathologic conditions. Hyperinflation may be particularly severe in chronic obstructive pulmonary disease(COPD) patients, in whom the functional residual capacity(FRC) often exceeds predicted total lung capacity(TLC). Hyperinflation reduces the diaphragmatic effectiveness as a pressure generator and reduces diaphragmatic contribution to chest wall motion. Ultrasonography has recently been shown to be a sensitive and reproducible method of assessing diaphragmatic excursion. This study was performed to evaluate how differences of diaphragmatic excursion measured by ultrasonography associate with normal subjects and COPD patients. Methods: We measured diaphragmatic excursions with ultrasonography on 28 healthy subjects(l6 medical students, 12 age-matched control) and 17 COPD patients. Ultrasonographic measurements were performed during tidal breathing and maximal respiratory efforts approximating vital capacity breathing using Aloka KEC-620 with 3.5 MHz transducer. Measurements were taken in the supine posture. The ultrasonographic probe was positioned transversely in the midclavicular line below the right subcostal margin. After detecting the right hemidiaphragm in the B-mode the ultrasound beam was then positioned so that it was approximately parallel to the movement of middle or posterior third of right diaphragm. Recordings in the M-mode at this position were made throughout the test. Measurements of diaphragmatic excursion on M-mode tracing were calculated by the average gap in 3 times-respiration cycle. Pulmonary function test(SensorMedics 2800), maximal inspiratory(PImax) and expiratory mouth pressure(PEmax, Vitalopower KH-101, Chest) were measured in the seated posture. Results: During the tidal breathing, diaphragmatic excursions were recorded $1.5{\pm}0.5cm$, $1.7{\pm}0.5cm$ and $1.5{\pm}0.6cm$ in medical students, age-matched control group and COPD patients, respectively. Diaphragm excursions during maximal respiratory efforts were significantly decreased in COPD patients ($3.7{\pm}1.3cm$) when compared with medical students, age-matched control group($6.7{\pm}1.3cm$, $5.8{\pm}1.2cm$, p< 0.05}. During maximal respiratory efforts in control subjects, diaphragm excursions were correlated with $FEV_1$, FEVl/FVC, PEF, PIF, and height. In COPD patients, diaphragm excursions during maximal respiratory efforts were correlated with PEmax(maximal expiratory pressure), age, and %FVC. In multiple regression analysis, the combination of PEmax and age was an independent marker of diaphragm excursions during maximal respiratory efforts with COPD patients. Conclusion: COPD subjects had smaller diaphragmatic excursions during maximal respiratory efforts than control subjects. During maximal respiratory efforts in COPD patients, diaphragm excursions were well correlated with PEmax. These results suggest that diaphragm excursions during maximal respiratory efforts with COPD patients may be valuable at predicting the pulmonary function.

  • PDF

Signal-Characteristic Analysis with Respect to Backing Material of PVDF-Based High-Frequency Ultrasound for Photoacoustic Microscopy (광음향 현미경을 위한 PVDF 기반 고주파수 초음파 변환기의 흡음층 소재에 따른 신호 특성 분석)

  • Lee, Junsu;Chang, Jin Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.112-119
    • /
    • 2015
  • Photoacoustic microscopy is capable of providing high-resolution molecular images, and its spatial resolution is typically determined by ultrasonic transducers used to receive the photoacoustic signals. Therefore, ultrasonic transducers for photoacoustic microscopy (PAM) should have a high operating frequency, broad bandwidth, and high signal-reception efficiency. Polyvinylidene fluoride (PVDF) is a suitable material. To take full advantage of this material, the selection of the backing material is crucial, as it influences the center frequency and bandwidth of the transducer. Therefore, we experimentally determined the most suitable backing material among EPO-TEK 301, E-Solder 3022, and RTV. For this, three PVDF high-frequency single-element transducers were fabricated with each backing material. The center frequency and -6 dB bandwidth of each transducer were ascertained by a pulse-echo test. The spatial resolution of each transducer was examined using wire-target images. The experimental results indicated that EPO-TEK 301 is the most suitable backing material for a PAM transducer. This material provides the highest signal magnitude and a reasonable bandwidth because a large portion of the energy propagates toward the front medium, and the PVDF resonates in the half-wave mode.

Effect of a Deep Learning Framework-Based Computer-Aided Diagnosis System on the Diagnostic Performance of Radiologists in Differentiating between Malignant and Benign Masses on Breast Ultrasonography

  • Ji Soo Choi;Boo-Kyung Han;Eun Sook Ko;Jung Min Bae;Eun Young Ko;So Hee Song;Mi-ri Kwon;Jung Hee Shin;Soo Yeon Hahn
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.749-758
    • /
    • 2019
  • Objective: To investigate whether a computer-aided diagnosis (CAD) system based on a deep learning framework (deep learning-based CAD) improves the diagnostic performance of radiologists in differentiating between malignant and benign masses on breast ultrasound (US). Materials and Methods: B-mode US images were prospectively obtained for 253 breast masses (173 benign, 80 malignant) in 226 consecutive patients. Breast mass US findings were retrospectively analyzed by deep learning-based CAD and four radiologists. In predicting malignancy, the CAD results were dichotomized (possibly benign vs. possibly malignant). The radiologists independently assessed Breast Imaging Reporting and Data System final assessments for two datasets (US images alone or with CAD). For each dataset, the radiologists' final assessments were classified as positive (category 4a or higher) and negative (category 3 or lower). The diagnostic performances of the radiologists for the two datasets (US alone vs. US with CAD) were compared Results: When the CAD results were added to the US images, the radiologists showed significant improvement in specificity (range of all radiologists for US alone vs. US with CAD: 72.8-92.5% vs. 82.1-93.1%; p < 0.001), accuracy (77.9-88.9% vs. 86.2-90.9%; p = 0.038), and positive predictive value (PPV) (60.2-83.3% vs. 70.4-85.2%; p = 0.001). However, there were no significant changes in sensitivity (81.3-88.8% vs. 86.3-95.0%; p = 0.120) and negative predictive value (91.4-93.5% vs. 92.9-97.3%; p = 0.259). Conclusion: Deep learning-based CAD could improve radiologists' diagnostic performance by increasing their specificity, accuracy, and PPV in differentiating between malignant and benign masses on breast US.

Degradation of PAHs in Aqueous Solution by UV Energy and Ultrasonic Irradiation (액상 PAHs의 자외선에너지와 초음파를 이용한 분해)

  • Kwon Sung-Hyun;Kim Jong-Hyang;Cho Dae-Chul
    • Journal of Environmental Science International
    • /
    • v.15 no.7
    • /
    • pp.669-676
    • /
    • 2006
  • PAHs are major pollutants that are widely distributed in soil and groundwater environment, so that may be regarded as carcinogens. We investigated the degradation kinetics of PAH in aqueous solution when low pressure UV energy and ultrasonic irradiation were applied. Phenanthrene and pyrene were used as model compounds. The degrees of degradation of these compounds with time were analyzed with a GC/MSD (SIM-mode). UV photolysis experiments showed that phenanthrene was reduced by 90 -67% at initial concentrations of 1 ppm to 8ppm whilst it decreased to 50% at 10 ppm. Under the same conditions pyrene was degraded up to about 75% at lower initial concentrations but the reduction efficiency dropped to a level of 34 to 29% at the higher concentrations above 8 ppm. The reaction orders for phenanthrene and pyrene were found to be zero-th and ca. -0.4th order, respectively, thus implying that the reported assumption of pseudo 1st order reaction for some PAHs would be no longer valid. PAH degradation was roughly proportional to the intensity of UV (number of lamps), exhibiting maximum 92.5% of the degradation efficiency. The solution pH was lowered to 4.4 from 6.4 during the experiments partially because the carbons decomposed by the energy reacted with oxygen radicals to produce carbon dioxides. Ultrasonic irradiation on phenanthrene solutions gave relatively poor results which matched to 50 to 70% of degradation efficiency even at 2 ppm of initial concentration. Phenanthrene was found to be degraded more efficiently than pyrene for the two energy sources. Ultrasound also followed the same reaction kinetics as UV energy on PAH degradation.

Non-Contact Ultrasonic Testing of Aircraft Joints using Laser Generated Lamb Wave (레이저 여기 램파를 이용한 항공기 판재 접합부의 비접촉식 초음파 검사)

  • Jhang, Kyoung-Young;Kim, Hong-Joon;Ceringlia, Donatella;Djordjevic, Boro
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.163-168
    • /
    • 2001
  • Due to aging, adhesively bonded and riveted aircraft lap joints can contain distends, cracks around rivet holes, fatigue induced flaws, and corrosion. It is required for the safety of aircraft to inspect these defects through the whole region of mint in rapid speed. Bond quality or adhesively bonded and riveted aluminum lap splice joints is investigated using non-contact remote ultrasonic nondestructive evaluation (NDE). Non-contact ultrasonic tests are performed using laser generation and air-coupled transducer detection. A Q-switched Nd:YAG laser and a periodic transmission mask are used to generate a selected Lamb mode. The Lamb wave is generated on one side of the lap splice joint, propagates along the plate, interacts with the joint and is detected on the other side by a micromachined air-coupled capacitance transducer. Analysis of recorded signals allows to evaluate the condition of the bond.

  • PDF

Establishment of a prediction table of parturition day in Shih-tzu bitches with ultrasound scanning (Shih-tzu견에서 초음파 검사에 의한 분만일 예시표 확립)

  • Kim, Bang-sil;Ko, Jin-sung;Lee, Sun-ae;Cho, Yang-tak;Kim, Jae-pung;Oh, Ki-seok;Kim, Jong-taek;Park, In-chul;Kim, Young-hong;Son, Chang-ho
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.2
    • /
    • pp.303-310
    • /
    • 2004
  • To establish a prediction table of parturition day real-time B-mode ultrasonographic examinations were performed in 12 pregnant Shih-tzu bitches. Measurement of inner chorionic cavity diameter and fetal head diameter was performed from 15 days of gestation to parturition. These were converted retrospectively based on the day of parturition (Day 0). The data of inner chorionic cavity diameter obtained from Day -44 to Day -25 and fetal head diameter obtained from Day -25 to Day -1 were used to compile a prediction table of parturition day. The 22 pregnant Shih-tzu with unknown mating time were examined to assess an accuracy of the table established in this study. And these results were applied to the prediction of parturition day and compared to actual parturition day. Parturition day prediction based on the inner chorionic cavity diameter and fetal head diameter was 100% accurate within ${\pm}2$ days. In addition, the accuracy for parturition day within 0, ${\pm}1$, and ${\pm}2$ days interval using the prediction table of parturition day were 68, 82, and 100%, respectively. Therefore, the prediction table of parturition day seems to be a useful tool for the prediction of parturition day in practice.