• Title/Summary/Keyword: Ultrasound Follow Up

Search Result 177, Processing Time 0.03 seconds

New Perspectives in Pediatric Nonalcoholic Fatty Liver Disease: Epidemiology, Genetics, Diagnosis, and Natural History

  • Ko, Jae Sung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.6
    • /
    • pp.501-510
    • /
    • 2019
  • Nonalcoholic fatty liver disease (NAFLD) is the most common cause of chronic liver disease in children. The global prevalence of pediatric NAFLD from general populations is 7.6%. In obese children, the prevalence is higher in Asia. NAFLD has a strong heritable component based on ethnic difference in the prevalence and clustering within families. Genetic polymorphisms of patatin-like phospholipase domain-containing protein 3 (PNPLA3), transmembrane 6 superfamily member 2, and glucokinase regulatory protein (GCKR) are associated with the risk of NAFLD in children. Variants of PNPLA3 and GCKR are more common in Asians. Alterations of the gut microbiome might contribute to the pathogenesis of NAFLD. High fructose intake increases the risk of NAFLD. Liver fibrosis is a poor prognostic factor for disease progression to cirrhosis. Magnetic resonance spectroscopy and magnetic resonance proton density fat fraction are more accurate for steatosis quantification than ultrasound. Noninvasive imaging methods to assess liver fibrosis, such as transient elastography, shear-wave elastography, and magnetic resonance elastography are useful in predicting advanced fibrosis, but they need further validation. Longitudinal follow-up studies into adulthood are needed to better understand the natural history of pediatric NAFLD.

Endoscopic Resection of Xanthogranulomatous Gastritis Presenting as a Subepithelial Tumor: A Case Report

  • Kim, Tae Wan;Kim, Tae Ho;Kim, Chang Whan;Chang, Jae Hyuck;Han, Sok Won;Kim, Jae Kwang
    • The Korean journal of helicobacter and upper gastrointestinal research
    • /
    • v.18 no.3
    • /
    • pp.198-203
    • /
    • 2018
  • Xanthogranulomatous gastritis (XGG) presenting as a subepithelial tumor (SET) is a very rare entity. We report a case of SET-like XGG diagnosed and treated with endoscopic resection. A 55-year-old female patient was initially referred with a 1.5-cm SET located at the anterior wall of the middle antrum. Endoscopic ultrasound examination revealed submucosal invasion without any perigastric lymph node enlargement. Endoscopic resection was performed for an accurate diagnosis and treatment, and the lesion was diagnosed histopathologically as XGG. At the 18-month follow-up after endoscopic resection, there was no evidence of XGG recurrence. SET-like XGG is very rare and the diagnosis is a preoperative challenge. However, inflammatory tumors should be considered in the differential diagnosis of SET.

The Potential of Yangdorak Diagnosis Application of Gallstone (담석증에 대한 양도락 진단의 활용 가능성)

  • Han, Gyu Eon
    • The Journal of Korean Medicine
    • /
    • v.45 no.1
    • /
    • pp.139-149
    • /
    • 2024
  • Objectives: The aim of the study was to investigate the potential of Yangdorak diagnosis application against gallstone scanned by Ultrasound diagnosis. Method: For this aim, among 97 patients who had visited Julip Korean Medicine Clinic from July 2016 to June 2023, 30 patients with no gallstone as a control group and 67 patients with gallstone and diagnosed by ultrasonography, were subjected to Yangdorak diagnosis. Then, the changes in Gallbladder Meridian (GB) value as F5 AVE(average of left and right GB value) by Yangdorak were comparatively analyzed between gallstone and non-gallstone groups and statistical significance was evaluated by Tukey's multiple comparison test using Prism software. Results: After all subjects were evaluated by the Yangdorak and ultrasonography to assess the potential of the Yangdorak diagnosis for gallstone, it was noteworthy that the Yangdorak values relevant to F5 AVE of female gallstone group(N=36) were significantly (p<0.001) decreased compared to the control group (N=30), while there was no significance in male gallstone group(N=31). Also, it was recognized significant difference between male and female groups. Conclusion: Based on these results, if the Yangdorak value can be estimated from a decrease with clinical symptom in female patient, it is recommended to follow up the ultrasonography test for diagnosing the gallstone.

Degenerating Thyroid Nodules: Ultrasound Diagnosis, Clinical Significance, and Management

  • Jie Ren;Jung Hwan Baek;Sae Rom Chung;Young Jun Choi;Chan Kwon Jung;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.947-955
    • /
    • 2019
  • Degenerating nodules (DNs), which primarily manifest as benign thyroid nodules, are one of the main causes of discordance in ultrasonography (US) and cytological assessments. Intranodular hemorrhage is one of the mechanisms contributing to discordant nodules, and an impaired blood supply may explain further DN shrinkage and infarction. The surgical specimens can be divided into acute and chronic stages based on the histological changes, which usually mimic the US features of malignant tumors. Serial US follow-up should be recommended instead of other unnecessary procedures. However, repeated fine-needle aspiration, diagnostic surgery, or core-needle biopsy may still be necessary for indeterminable or highly suspicious DNs.

Imaging Findings of Axillary Granular Cell Tumor in a Patient with Breast Cancer History: A Case Report (유방암 과거력을 가진 환자에서 액와부 과립세포종의 영상 소견: 증례 보고)

  • Jeongeum Oh;Ji Yeon Park;Mee Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1176-1180
    • /
    • 2023
  • Granular cell tumors (GCTs) are rare soft tissue tumor, originating from neural or perineural cells. We present a case of axillary GCT in a 69-year-old woman with breast cancer history and discuss the various radiologic findings. US revealed a circumscribed oval heterogeneous iso- and hyperechoic mass in the left axilla. Chest CT showed a well-defined, oval, and mildly enhancing mass in the left axilla on the lateral aspect of the pectoralis muscle. A final diagnosis of GCT was made through US-guided core needle biopsy. Follow-up US showed no significant changes in the axillary GCT. Familiarity with GCT may facilitate early diagnosis and subsequent management.

Usefulness of Ultrasonographic Examination in Diagnosis and Follow-up of the Frozen Shoulder (동결견의 진단과 치료 경과 판정에 대한 초음파 검사의 유용성)

  • Choi, Chang-Hyuk;Kim, Seok-Jun;Lee, Sang-Hwa;Kim, Hee-Soo;Shim, Jung-Hyun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose: In order to know the effectiveness of ultrasonographic examination in diagnosis and follow-up evaluation for the frozen shoulder, we compared those with contralateral side in initial and after steroid injection. Materials and Methods: For the 20 unilateral frozen shoulder from July 2012 to July 2013, ultrasonographic examination was tried using reference line 1 (CBT: distance from coracoid process to LHB tendon) and line 2 (CBG: distance from coracoid process to bicipital groove). We tried 1 time steroid injection and compared the improvement in gross motion and reference line with 2 month, 4 month, and 6 month's serial ultrasonographic examination. Results: The differences on CBT line between lesion side and normal side were -5.6 mm, -5.0 mm, and -4.3 mm in neutral (Neut), external rotation (ER) and internal rotation (IR), respectively. The differences on CBG line were -6.1 mm, -4.7 mm, and -5.0 mm respectively (p<0.05). The changes in the reference line after steroid injection were evaluated at 2 month (CBT: -4.8 mm, -3.5 mm, -2.6 mm / CBG: -4.7 mm, -4.0 mm, -3.6 mm), 4 month (CBT: -4.7 mm, -3.2 mm, -1.7 mm / CBG: -4.3 mm, -3.7 mm, -1.2 mm), and 6 month (CBT: -1.1 mm, -2.9 mm, -0.5 mm / CBG: -1.2 mm, -0.7 mm, -0.9 mm). The gross motion was improved at 4 month after injection, from elevation $108^{\circ}$, ER $32^{\circ}$, IR L5 in initial to $133^{\circ}$, $42^{\circ}$, L3 respectively (p<0.05). Pain improved from 7.5 in initial to 3.0 at 2 month on visual analog scale (VAS). Conclusion: The serial examination after steroid injection revealed that the delayed improvement on reference line (6 month) compared with pain (2 month) or gross motion (4 month). Dynamic ultrasonogram was useful in diagnosis and follow-up evaluation of frozen shoulder.

  • PDF

Ultrasound-guided Extracorporeal Shock Wave Therapy Combined with Multiple Needling for Calcific Tendinitis in Shoulder (견관절의 석회화 건염에 대한 초음파 유도하 다발성 천공술 및 고에너지 체외 충격파 병합치료)

  • Jung, Tae Wan;Song, Dong Ik;Lee, Soon Hyuck;Jeoung, Woong Kyo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: To evaluate the effectiveness of ultrasonography-guided combined multiple needling and high-energy extracorporeal shock wave therapy (ESWT) for calcific tendinitis of the shoulder. Materials and Methods: We included 42 calcific tendinitis patients who underwent ultrasonograpy-guided multiple needling followed by high-energy ESWT who visited the clinic from January 2010 to June 2013. The average follow up period was 45 weeks. Clinical evaluation was done before and after 12 weeks from treatment, in clinical terms using pain visual analogue scale (P-VAS), ASES, UCLA scores reflecting performance and symptom improvement, and in sonographic terms by studying the changes in size of the calcific nodules. Results: A statistically significant improvement was seen in P-VAS, ASES, UCLA scores and decreased calcification size on sonographic evaluation. Conclusion: Ultrasonography-guided combined multiple needling and high-energy ESWT is considered as a useful method which could provide clinical function improvement and reduction of calcification deposit.

  • PDF

Analysis of Hematological Factor to Predict Plaque of the Carotid Artery in Ultrasound Images (경동맥초음파에서 죽상경화반을 예측하는 혈액학적 수치의 분석)

  • Yang, Sung Hee;Kang, Se Sik;Lee, Jinsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.187-193
    • /
    • 2016
  • In this study, we performed the carotid artery ultrasound targeting 140 subjects who have conducted to evaluate the changes in intima-media thickness(IMT) and plaque correlated with the presence or absence of a hematological test of the carotid artery. Considering that the IMT thickness more than 1mm is abnormal based on the carotid artery ultrasound to assess the presence or absence of plaque, and examined the correlation by classifying the blood lipid value and the fasting blood glucose level through the serum test. Consequently, the fasting blood glucose level is being analyzed as independent predictors of causing dental plaque(p=0.033), cut off value was determined as 126 mg/dL(sensitivity 56.25%, specificity 68.38%) in ROC curve analysis. Furthermore, the odds ratio appeared 1.01 times the value in the Logistic regression. Therefore, it seemed that the necessity to prospective studies in a number of subjects are considered, and also taking into account a number of blood test values along with the sonography of the carotid artery as a valuable part for effective primary prevention and follow-up observation of the cardiac and brain vascular disease is highly recommended.

Detection of Contralateral Breast Cancer Using Diffusion-Weighted Magnetic Resonance Imaging in Women with Newly Diagnosed Breast Cancer: Comparison with Combined Mammography and Whole-Breast Ultrasound

  • Su Min Ha;Jung Min Chang;Su Hyun Lee;Eun Sil Kim;Soo-Yeon Kim;Yeon Soo Kim;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.867-879
    • /
    • 2021
  • Objective: To compare the screening performance of diffusion-weighted (DW) MRI and combined mammography and ultrasound (US) in detecting clinically occult contralateral breast cancer in women with newly diagnosed breast cancer. Materials and Methods: Between January 2017 and July 2018, 1148 women (mean age ± standard deviation, 53.2 ± 10.8 years) with unilateral breast cancer and no clinical abnormalities in the contralateral breast underwent 3T MRI, digital mammography, and radiologist-performed whole-breast US. In this retrospective study, three radiologists independently and blindly reviewed all DW MR images (b = 1000 s/mm2 and apparent diffusion coefficient map) of the contralateral breast and assigned a Breast Imaging Reporting and Data System category. For combined mammography and US evaluation, prospectively assessed results were used. Using histopathology or 1-year follow-up as the reference standard, cancer detection rate and the patient percentage with cancers detected among all women recommended for tissue diagnosis (positive predictive value; PPV2) were compared. Results: Of the 30 cases of clinically occult contralateral cancers (13 invasive and 17 ductal carcinoma in situ [DCIS]), DW MRI detected 23 (76.7%) cases (11 invasive and 12 DCIS), whereas combined mammography and US detected 12 (40.0%, five invasive and seven DCIS) cases. All cancers detected by combined mammography and US, except two DCIS cases, were detected by DW MRI. The cancer detection rate of DW MRI (2.0%; 95% confidence interval [CI]: 1.3%, 3.0%) was higher than that of combined mammography and US (1.0%; 95% CI: 0.5%, 1.8%; p = 0.009). DW MRI showed higher PPV2 (42.1%; 95% CI: 26.3%, 59.2%) than combined mammography and US (18.5%; 95% CI: 9.9%, 30.0%; p = 0.001). Conclusion: In women with newly diagnosed breast cancer, DW MRI detected significantly more contralateral breast cancers with fewer biopsy recommendations than combined mammography and US.

Clinical Study of Long Term Effect of Transvaginal Ultrasound Guided Radiofrequency Myolysis for Treatment of Uterine Leiomyoma (자궁근종 치료를 위한 질경유 초음파 유도하 고주파 자궁근종용해술의 장기간 효과에 대한 임상적 연구)

  • Lee, Woo-Seok;Lee, Il-Han;Kim, Dong-Ho;Lee, Sang-Hun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.35 no.1
    • /
    • pp.77-82
    • /
    • 2008
  • Objective: This study was performed to investigate the efficacy and safety of radiofrequency (RF) myolysis under transvaginal ultrasound guidance. Methods: Transvaginal RF myolysis had been performed in one hundred nine women with uterine leiomyoma at Chung-Ang University hospital between Dec. 2004 and Mar. 2007. All patients, mean aged $42.8{\pm}5.8$ years, desired their uterine conservation. Patients underwent physical examination, transvaginal pelvic ultrasound for measurement of the lesions preoperatively. Follow up was done at 1 week, 1 month, 3 months, 6 months after RF myolysis by same physician and measurement of size and volume of myoma and improvement of myoma specific symptoms such as menorrhagia and dysmenorrhea were checked at each visit. Results: The mean maximal diameter of myomas treated by RF myolysis was $6.1{\pm}0.5\;cm$ and average time of the procedure was $16.3{\pm}8.5$ minutes. A significant decrease of myoma size and volume was observed at 1 month after myolysis. Mean reduction in maximal diameter was $29.9{\pm}4.8%$ at 1 week (p<0.001), $41.5{\pm}1.5%$ at 1 month (p=0.05), $46.2{\pm}3.9%$ at 3 months (p=0.003), $54.6{\pm}6.1%$ at 6 months (p<0.001) after RF myolysis respectively. Mean reduction in volume was $44.4{\pm}8.3%$ (p=0.001), $68.1{\pm}4.2%$ (p=0.035), 73.9$73.9{\pm}4.8%$ (p=0.042), $84.5{\pm}5.1%$ (p<0.001) at the same follow up period respectively. Significant improvement of symptom was observed at 3 months after RF myolysis. Transient low abdominal pain and prolonged vaginal bleeding were detected in 3 patients each but spontaneously resolved and no serious complication has been noticed or found. Conclusion: This study shows transvaginal RF myolysis could be a safe and effective method to treat uterine leiomyoma, allowing uterine conservation with significant volume reduction and rapid return to normal activity.