• 제목/요약/키워드: Ultrasonography Imaging

검색결과 534건 처리시간 0.032초

Computed tomographic findings of peritoneal lymphomatosis in a cat: a case report

  • Sung, Ah Won;Kim, Juyeong;Lee, Youngwon;Choi, Hojung
    • Korean Journal of Veterinary Research
    • /
    • 제62권2호
    • /
    • pp.17.1-17.5
    • /
    • 2022
  • A 12-year-old castrated male Persian cat presented with abdominal distension and anorexia. The radiography revealed ascites, pleural effusion, and a cranioventral mediastinal mass. Ultrasonography showed a well-defined mass lesion within a thickened ileal segment with a transmural loss of layering and multiple hyperechoic nodules arising from the peritoneum. Computed tomography showed peritoneal thickening with contrast enhancement, a bulky heterogeneous ileal mass, and mesenteric involvement with diffuse nodules. An alimentary lymphoma was confirmed by fine needle aspiration of the small intestinal mass. This report describes the imaging features of lymphoma with peritoneal lymphomatosis in a cat.

A Study of the Development for Fatty Liver Quantification Diagnostic Technology from Ultrasound Images using a Simulated Fatty Liver Phantom (모사 지방간 팬텀을 활용한 초음파영상에서 지방간 정량화 진단 기술 개발을 위한 연구)

  • Yei-Ji Lim;Seung-Man Yu
    • Journal of the Korean Society of Radiology
    • /
    • 제18권2호
    • /
    • pp.135-144
    • /
    • 2024
  • Ultrasonography examination has limitations in quantifying hepatic fat quantification. Therefore, this study aimed to experimentally demonstrate whether changes in signal attenuation during ultrasound imaging can be quantified using simulated hepatic phantoms to assess hepatic fat content. Additionally, we aimed to evaluate the potential of ultrasound imaging for diagnosing hepatic fatty liver by analyzing the relationship between hepatic fat content and signal intensity in ultrasound images. In this study, we developed a total of five stimulated hepatic phantoms by homogeneously mixing water and oil. We confirmed the fat content of the phantoms using magnetic resonance imaging (MRI) and ultrasound imaging, and measured signal intensity according to distance in ultrasound images to analyze the correlation and mean comparison between fat content and signal intensity. We observed that as the fat content increased, the ultrasound penetration intensity decreased, confirming the potential for quantifying hepatic fat content using ultrasound. Additionally, the analysis of the correlation between the measured fat content using MRI and the signal intensity measured in ultrasound images showed a high correlation. Statistical analysis in our study confirmed that as the fat content increased, the slope representing signal during ultrasound imaging (US-GRE) decreased. In this study, it was statistically confirmed that the US-GRE value of ultrasound images gradually decreases as the fat content increases, and it is believed that US-GRE can serve as a biomarker expressing fatty liver content.

MR Spectroscopy and Diffusion Weighted Imaging Findings of Primary Non-Hodgkin Lymphoma of the Breast: Two Case Reports (유방에 발생한 일차성 비호지킨림프종의 자기공명 분광법 및 확산강조 영상: 2예)

  • Nam, Sang Yu;Yoo, Eun Young;Choi, Hye-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권2호
    • /
    • pp.176-181
    • /
    • 2014
  • Primary non-Hodgkin lymphoma (NHL) of the breast is a very rare disease, and the mammographic and ultrasonographic findings of breast lymphoma are variable. There are several reports of magnetic resonance (MR) imaging findings in patients with breast lymphomas; however, few reports have described the findings observed on MR spectroscopy or the features of diffusion weighted (DW) imaging. The authors report the findings of classical MR imaging, MR spectroscopy and DW imaging of a 48-year-old woman and a 40-year-old woman with primary non-Hodgkin's lymphoma of breasts. Mammography and breast ultrasonography revealed a mass with circumscribed margin. The mass showed strong enhancement after contrast injection on MR imaging. DW imaging showed reduced diffusion and high-amplitude choline (Cho) peak at 3.22 ppm was detected by single voxel MR spectroscopy which was consistent with malignancy.

Vesicoureteral Reflux and Renal Scar (방광요관역류와 신반흔)

  • Nam, Hee-Young;Shin, Joon-Heon;Lee, Jun-Ho;Choi, Eun-Na;Park, Hye-Won
    • Childhood Kidney Diseases
    • /
    • 제10권2호
    • /
    • pp.201-212
    • /
    • 2006
  • Purpose : Vesicoureteral reflux(VUR) is the major risk factor of urinary tract infection(UTI) in children and may result in serious complications such as renal scarring and chronic renal failure. The purpose of this study was to evaluate the relationship between VUR and renal scar formation, the usefulness and correlation of various imaging studies in reflux nephropathy, and the spontaneous resolution of VUR. Methods : We retrospectively reviewed 106 patients with VUR with no accompanying urogenital anomalies in the Department of Pediatrics, Bundang CHA Hospital during the period from Jan. 1996 to Mar. 2005. Ultrasonography and $^{99m}Tc$-dimercaptosuccinic acid(DMSA) scan were performed in the acute period of UTI. Voiding cystourethrography(VCUG) was performed 1 to 3 weeks after treatment with UTI. Follow-up DMSA scan was performed 4 to 6 months after treatment and a follow-up VCUG was performed every 12 months. Results : The mean age at detection of VUR was $13.8{\pm}22.2$ months and the male to female ratio was 2:1. The incidence of renal scarring showed a tendency of direct correlation between severity of VUR(P<0.001) and abnormal findings of renal ultrasonography(P<0.01). 63.2%(24 of 38 renal units) of renal parenchymal defects present in the first DMSA scan disappeared on follow-up DMSA scans. Follow-up DMSA scans detected renal scars in 7(14%) of 50 renal units with ultrasonographically normal kidneys. Meanwhile, ultrasonography did not show parenchymal defects in 7(36.8%) of 19 renal units where renal scarring was demonstrated on a follow-up DMSA scan. The spontaneous resolution rate of VUR was higher(75%) in cases with low grade(I to III) VUR(P<0.01). Conclusions : The presence and severity of VUR and abnormal findings of renal ultrasonography significantly correlated with renal scar formation. DMSA scan was useful in the diagnosis of renal defects. Meanwhile renal ultrasonography was an inadequate method for evaluating renal parenchymal damage. Therefore, follow-up DMSA scans should be performed to detect renal scars even in children with low-grade VUR and normal renal ultrasonography.

  • PDF

Transobturator Tape Under the Ultrasonographic Guidance -A Case Report- (초음파 유도하 경폐쇄공 띠의 제거 -증례 보고-)

  • Min, Kyoung-Dae;Hwang, Seok-Ha;Kang, Seung-Gu;Lee, Byung-Ill
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • 제5권2호
    • /
    • pp.118-122
    • /
    • 2012
  • Taking history and ultrasonography is important to detect foreign body which might be located in the soft tissue. We encountered a case of soft tissue foreign body (transobturator tape) in a patient who had been treated with the impression of adductor myositis resulting from vagina fistula. The foreign body was found through ultrasonographic examination and the patient's symptom was relieved after removal of the foreign body from the ultrasonography-guided operation. Clinicians should keep in mind the fact that foreign bodies may exist when the inflammation persists without appreciable cause and ultrasonography can be useful tool in case of small fibrous band not detected with magnetic resonance imaging due to inflammatory change of the surrounding tissues.

  • PDF

Parametric Image Generation and Enhancement in Contrast-Enhanced Ultrasonography (조영증강 초음파 진단에서 파라미터 영상 생성 및 개선 기법)

  • Kim, Shin-Hae;Lee, Eun-Lim;Jo, Eun-Bee;Kim, Ho-Joon
    • KIPS Transactions on Software and Data Engineering
    • /
    • 제6권4호
    • /
    • pp.211-216
    • /
    • 2017
  • This paper proposes image processing techniques that improve usability and performance in a diagnostic system of the contrast-enhanced ultrasonography. For a methodology for visualizing diagnostic parameter data in an ultrasonic medical image, an expression of transition time data with successive pixel values and a method of generating a lesion diagnostic parameter image with four categorized values are presented. We also introduce a MRF-based image enhancement technique to eliminate noises from generated parametric images. Such parametric image generation technique can overcome the difficulty of discriminating dynamic change in patterns in the ultrasonography. The technique clarifies the contour of the region in the original image and facilitates visual determination of the characteristics of the lesion through four colors. With regard to this MRF-based image enhancement, we define the energy function of consecutive pixel values and develop a technique to optimize it, and the usability of the proposed theory is examined through experiments with medical images.

Comparison of 99mTc-DMSA Renal Scan and Power Doppler Ultrasonography for the Detection of Acute Pyelonephritis and Vesicoureteral Reflux

  • Bae, Hee Jung;Park, Yong-Hoon;Cho, Jae Ho;Jang, Kyung Mi
    • Childhood Kidney Diseases
    • /
    • 제22권2호
    • /
    • pp.47-51
    • /
    • 2018
  • Purpose: Urinary tract infection (UTI) is one of the common infectious diseases in children. Several imaging modalities can be used to confirm the presence of acute pyelonephritis (APN). Among them the 99mTcdimercaptosuccinic acid renal scan (DMSA scan) is used as a gold standard for diagnosis. Ultrasonography technology is evolving. Therefore, in this study, we investigated the sensitivity and specificity of Power Doppler ultrasonography (PDU) compared to the results from the previous study. Methods: There were 260 patients included in this study, aged between 1 and 12 months old. The patients were admitted to the Yeungnam University Medical Center between January 2008 and December 2015. All patients underwent both DMSA scan and PDU within 5days of admission. Voiding cystourethrography (VCUG) was performed in 195 patients with abnormal DMSA scan or PDU. Results: The diagnostic sensitivity of APN using PDU was 45.5% and specificity was 85.5% in 260 patients following detection of a defect on DMSA scan that was defined as APN. The diagnostic sensitivity and specificity of PDU for VUR were 65.5 % and 60.1%, respectively. The diagnostic sensitivity and specificity of DMSA scan for VUR were 95.7% and 14.1%, respectively. Conclusion: PDU has a high specificity but low sensitivity, so there are limitations in using it to replace a DMSA scan for the diagnosis of APN in children. DMSA scan and PDU have different sensitivity and specificity in diagnosis of VUR, respectively. Therefore, we suggest that the sensitivity and specificity of each test can be helpful in diagnosing APN and VUR when used in conjunction.

The reproducibility of ultrasonographic assessment of local cross-sectional dimensions of masseter muscle (초음파를 이용한 교근의 단면두께 측정의 재현성에 대한 연구)

  • Chung Gi-Chung;Han Won-Jeong;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제35권2호
    • /
    • pp.97-103
    • /
    • 2005
  • Purpose : To determine if ultrasonography is a reliable technique to assess masseter muscle sites within intra- and interobserver and the scanning level and/or the muscle condition affect local cross-sectional dismension (LCSD) measurements of masseter muscle. Materials and Methods : 10 subjects without sign and symptom of temporomandibular disorders and missing posterior teeth were examined by ultrasonography. Bilateral ultrasonographic examinations were performed with a linear (B-scan) 7.5 MHz small-part transducer to register LCSDS of the masseter muscle on three different levels. Scans were made on relaxed and clenching condition. Three oral and maxillofacial radiologists measured at two sessions with a time interval of at least 5 minutes. Results : Variables such as 'condition' and 'level' had a significant effect on muscle measurements (p<0.05). There was no significant difference between 'sessions'(p>0.05) and 'observers' (p>0.05). LCSDS on lower scan level were significantly thinner than those on upper and middle level. Those on clenching condition were significantly thicker than those on relaxed condition (p<0.05). The scanning level with the highest reproducibility was middle with clenching condition (ICC=0.90, $MSE=0.55\%$). Conclusion : The data suggested that ultrasonography was a reliable method for measuring LSCD of masseter muscle in intra- and Interobserver and middle scan level showed the most reliable data.

  • PDF

Chest Wall Lipogranuloma after Hydrogel Implant Rupture: Case Report

  • Park, So Yoon;Han, Boo-Kyung;Cho, Eun Yoon;Bang, Sa-Ik
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권3호
    • /
    • pp.191-195
    • /
    • 2015
  • We present a 53-year-old woman with a large chest wall mass in the interpectoral space, which was eventually confirmed as a lipogranuloma resulting from hydrogel implant rupture. Ultrasonography (US) showed reduced implant volume with surrounding peri-implant fluid collection, suggesting the possibility of implant rupture. A heterogeneously hypoechoic mass was found between the pectoralis major and minor muscles adjacent to the ruptured implant. On magnetic resonance imaging (MRI), there was a large mass in the left interpectoral space of the upper inner chest wall. The mass showed slightly high signal intensity (SI) on pre-contrast T1-weighted image (WI) with mixed iso and high SI on T2-WI. The signal of the mass was suppressed using the water suppression technique but not with the fat suppression technique on T2-WI. The mass showed diffuse enhancement upon contrast enhancement. The enhancing kinetics showed persistent enhancement pattern. US-guided core needle biopsy revealed a lipogranuloma and removal confirmed a ruptured PIP hydrogel implant.

$^{18}F$-FDG PET/CT Finding in a Case of Xanthogranulomatous Pyelonephritis (황색육아종성 신우신염 환자의 $^{18}F$-FDG PET/CT 소견 1예)

  • Choi, Bong-Hoi;Hong, Sun-Pyo;Yoon, Joon-Kee;Pai, Ki-Soo;Hong, Jeong;Yim, Hyun-Ee
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권2호
    • /
    • pp.150-153
    • /
    • 2009
  • Xanthogranulomatous pyelonephritis is an uncommon chronic renal infection, which is usually found on middle-aged women and is rare in infant. Sometimes it forms focal mass like lesion of kidney with pathologically characteristic lipid-laden macrophage. A 1-month female infant was admitted for fever and moaning sound. On work-up of urinary tract infection, abdomen ultrasonography and computed tomography revealed a large mass on the upper portion of right kidney and PET/CT showed homogeneously increased $^{18}F$-FDG uptake. The radical nephrectomy of right kidney was performed and histology revealed a focal xanthogranulomatous pyelonephritis. To our knowledge, this is the first report presenting the finding of $^{18}F$-FDG PET/CT in the childhood xanthogranulomatous pyelonephritis.