• Title/Summary/Keyword: Ultrasonographic imaging

Search Result 105, Processing Time 0.027 seconds

Survey on Utilization of Ultrasonographic Machine in Small Animal Clinics in South Korea (전국 소동물 병원의 초음파 진단기기 및 활용도 현황조사)

  • Chang, Jin-Hwa;Paik, Min-Ji;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.28 no.4
    • /
    • pp.408-414
    • /
    • 2011
  • This study was carried out to analyze the utilization of ultrasound machines in animal hospitals and focused on surveying the present condition of diagnostic ultrasound on veterinary medicine in South Korea. Total 279 veterinary hospitals were surveyed with e-mail questionnaires or telephone survey. E-mail questionnaires consist of 17 items of questions including existence of ultrasound machine, types of ultrasound machine, ultrasound examination costs, frequency, purposes, other diagnostic imaging equipments, and referring system of ultrasound. Telephone surveys asked about the existence of the ultrasound machine and types of the ultrasound machine to 279 animal hospitals. Two hundred and seventy-one out of 279 animal hospitals holds ultrasound machine. Seventy-two percents clinics purchased used ultrasonographic machines and mean years after the date of manufacture is 7.5 years and the proportion of superannuated machines are relatively high. Also many clinicians prefer single organ scanning rather than general scan technique and more than 60% of clinics perform ultrasonographic examination less than 5 times a week. Clinics located in Seoul area tend to have more expensive and brand-new ultrasonographic machines and the distribution of radiology specialist are higher in this area. Problems associated with the present condition were oversupply of machines, unequal distribution of the medical equipment in different localities, ineffective use of the medical equipment, and high percentage of old poor-quality medical equipments. There should be a viable alternative proposal to control amount and quality of the ultrasound machines. Also, the improved management system for the ultrasound machine is required.

Diagnostic Approach of Hepatic Mass using Ultrasound Guided Fine Needle Aspiration in a Dog (개에서 초음파를 이용한 간 종괴의 세침흡인술 증례)

  • 최호정;이기창;최민철;윤정희
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.181-183
    • /
    • 2004
  • Hepatic mass was aspirated under the guidance with ultrasound in 9-year old female maltese with signs of anorexia, hematochezia, vomiting, depression, and abdominal distension. Radiographic and abdominal ultrasonographic examinations were performed, which revealed enlarged tubular shaped uterine mass and solitary, small round hyperechoic hepatic mass dorsal to gall bladder as an incidental finding. Ultrasound-guided fine needle aspiration was completed, but histologic confirmation should be made for definitive diagnosis by tissue core or wedge biopsy.

A Study on the Safety of Electromagnetic Wave of Medical Imaging System (의료영상장치의 전자파 안전에 대한 연구)

  • Seon, Jong-Ryul;Lee, Won-Jeong;Rhim, Jae-Dong
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.11a
    • /
    • pp.103-112
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system ($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

  • PDF

A Study on the Safety of Electromagnetic Wave of Medical Imaging System (의료영상장치의 전자파 안전에 대한 연구)

  • Seon, Jong-Ryul;Lee, Won-Jeong;Rhim, Jae-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

MR Spectroscopy and Diffusion Weighted Imaging Findings of Primary Non-Hodgkin Lymphoma of the Breast: Two Case Reports (유방에 발생한 일차성 비호지킨림프종의 자기공명 분광법 및 확산강조 영상: 2예)

  • Nam, Sang Yu;Yoo, Eun Young;Choi, Hye-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.176-181
    • /
    • 2014
  • Primary non-Hodgkin lymphoma (NHL) of the breast is a very rare disease, and the mammographic and ultrasonographic findings of breast lymphoma are variable. There are several reports of magnetic resonance (MR) imaging findings in patients with breast lymphomas; however, few reports have described the findings observed on MR spectroscopy or the features of diffusion weighted (DW) imaging. The authors report the findings of classical MR imaging, MR spectroscopy and DW imaging of a 48-year-old woman and a 40-year-old woman with primary non-Hodgkin's lymphoma of breasts. Mammography and breast ultrasonography revealed a mass with circumscribed margin. The mass showed strong enhancement after contrast injection on MR imaging. DW imaging showed reduced diffusion and high-amplitude choline (Cho) peak at 3.22 ppm was detected by single voxel MR spectroscopy which was consistent with malignancy.

Magnetic Resonance Imaging and Ultrasonographic Evaluation of Canine Tarsus

  • Soomin Park;Sang-hwa Ryu;Jae-gwan Heo;Eun-jee Kim;Jihye Choi;Junghee Yoon
    • Journal of Veterinary Clinics
    • /
    • v.41 no.2
    • /
    • pp.79-87
    • /
    • 2024
  • The tarsus in dogs has a complex structure that makes its evaluation relatively challenging. Because an accurate diagnosis of the tarsus is difficult through basic examinations alone, imaging tests are essential. Previous studies have explored the anatomical and radiological features of the canine tarsus using several imaging modalities. However, the imaging utility of the tarsus across different modalities has not been thoroughly evaluated. This study aimed to visualize the tarsal structures using magnetic resonance imaging (MRI) and ultrasonography, compare their utility, and propose suitable imaging modalities and conditions for evaluating specific tarsal structures. Magnetic resonance imaging and ultrasound scans of the tarsus of four healthy dogs were performed, and two observers rated the utility of each image on a five-point scale. Although MRI is more beneficial for assessing the tarsal structures than ultrasound, ultrasound also appears clinically useful for evaluating the cranial tibialis muscle, deep digital flexor tendon, subcutaneous fat, joint space, and superficial digital flexor tendon. In addition, each structure of interest can be evaluated for optimal visibility using specific ultrasound sections, MRI sequences, and planes. In veterinary clinical practice, an initial assessment using ultrasound imaging with optimal visibility is required and if further evaluation is necessary, MRI examinations with optimal MRI sequences and planes can be performed.

Preoperative Three Dimensional Ultrasonographic Evaluation of the Rotator Cuff Tear (회전근 개 파열에 대한 수술 전 3차원 초음파 검사의 유용성)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Han, Jung-Il
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.24-28
    • /
    • 2008
  • Purpose: We wanted to determine if preoperative three dimensional (3D) ultrasonographic evaluation for rotator cuff tear is useful to measure the real size of a torn rotator cuff for performing an operation Materials and Methods: This study included 15 cases (7 males and 8 female), and these patients were confirmed to have a full thickness tear of the rotator cuff by 3D ultrasonography and the operative findings, as well as on the magnetic resonance imaging (MRI). The average age of the patients was 55.4yrs. Results: The average difference between the 3D ultrasonographic and operative measurements of the full thickness tear of the rotator cuff was 0.7 mm in the transverse length and 2.0 mm in the longitudinal length. Conclusion: The low error between the 3D ultrasonographic and intraoperative measurements of rotator cuff tear shows the usefulness of preoperative 3D ultrasonographic evaluation for rotator cuff tear.

Ultrasonographic and radiographic study on experimental cystitis in rabbit (실험적 방광염 유발 토끼에서의 초음파 및 방사선학적 연구)

  • Sung, Jai-ki;Chang, Dong-woo;Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.4
    • /
    • pp.973-990
    • /
    • 1996
  • To investigate diagnostic imaging of cystitis and to apply it to the small animal practice, ultrasonogram of urinary bladder with moderate distension(4ml/kg) and with complete distension(9ml/kg) to evaluate the irregularity and thickness of bladder, radiography and histopathological examination were performed after experimental cystitis induction. On double contrast cystography, mucosal membrane of the urinary bladder was smooth and thickening urinary bladder wall was not found before cystitis induction. At 3rd day post induction(PI), mucosal irregularity was noted at the cranioventral region of the urinary bladder. Thickening of the urinary bladder wall and filling defect was observed as well. Cystographic findings of 7, 10, 15, 21 day PI were similar to that of 3rd day PI. On ultrasonographic findings of the mural thickness in induction group, it was ascertain that the mural thickness with moderate distention was more thickened than with complete distention at transverse scan. Ultrasonographic findings at longitudinal scan were similar to those of transverse scan. On ultrasonographic findings of mucosal irregularity in induction group, from PI to 7 day PI, mucosal irregularity with moderate distention was more irregular than mucosal irregularity with complete distention. At 10 day PI, there was similarity between moderate distention and complete distention. On histopathologic examination of a section of urinary bladder taken 3 day PI, the mucosal and submucosa were infiltrated by a mixture of thick inflammatory exudate which was composed of neutrophil, plasma protein, bacterial colony and necrotic cells. Congestion, hemorrhage and edema were also observed in the submucosa. At 7th day PI, the mucosal change was similar to that of 3rd day PI, but neovascularization and fibroplasia were observed in the submucosa. At 15th and 21th day PI, mild hyperplasia of mucosal epithelium was observed in the mucosa. Deposition of collagen, neovascularization and severe diffuse infiltration of lymphocyte were observed. These results suggest that ultrasonographic examination with moderate distention is considered to be a more simple, rapid, noninvasive, sensitive and useful diagnostic method than other diagnostic methods for the diagnosis of the cystitis and the differential diagnosis of urinary tract infection.

  • PDF

Contraction Ratio Variation of the Lateral Abdominal Muscles in Elderly Gait

  • Yi, Jae-Hoon
    • PNF and Movement
    • /
    • v.16 no.2
    • /
    • pp.301-306
    • /
    • 2018
  • Purpose: This study aimed to describe and identify the relationship between gait and contracted ratios of the transverse abdominal (TrA), internal oblique (IO), and external oblique (EO) muscles. Methods: This study was conducted on 50 elderly people. The contracted ratios of the lateral abdominal muscles (LAM) were measured using the abdominal drawing-in maneuver (ADIM) and ultrasonographic imaging. Gait was measured using the timed up and go test and the 10 m walk test. Results: The contracted ratios of the TrA and IO muscles significantly increased after ADIM. Those of the TrA muscles showed a significant correlation with gait in the limited community ambulatory group. The contracted ratios of the IO and EO muscles showed a significant correlation with gait in the community ambulatory group. Conclusion: Our findings suggest a specific training on the relationship between gait speed and the activation of the LAM in elderly people.

Ultrasonographic Indeterminate Lymph Nodes in Preoperative Thyroid Cancer Patients: Malignancy Risk and Ultrasonographic Findings Predictive of Malignancy

  • Roh-Eul Yoo;Ji-hoon Kim;Jeong Mo Bae;Inpyeong Hwang;Koung Mi Kang;Tae Jin Yun;Seung Hong Choi;Chul-Ho Sohn;Jung Hyo Rhim;Sun-Won Park
    • Korean Journal of Radiology
    • /
    • v.21 no.5
    • /
    • pp.598-604
    • /
    • 2020
  • Objective: Proper management of lymph nodes (LNs) with ultrasonographic (US) indeterminate features in thyroid cancer patients remains elusive. We aimed to evaluate the malignancy risk and US findings predictive of malignancy for US indeterminate LNs in preoperative thyroid cancer patients through node-by-node correlation. Materials and Methods: A total of 348 LNs in 284 thyroid cancer patients, who underwent fine-needle aspiration or core-needle biopsy between December 2006 and June 2015, were included. We determined the malignancy risks for US probably benign, indeterminate, and suspicious categories. For US indeterminate LNs, which had neither echogenic hilum nor hilar vascularity in the absence of any suspicious finding, US findings were compared between benign and metastatic LNs using Mann-Whitney U test and Fisher's exact test. Results: US imaging diagnoses were probably benign in 20.7% (n = 72) cases, indeterminate in 23.6% (n = 82), and suspicious in 55.7% (n = 194). Malignancy risk of US indeterminate LNs (19.5% [16/82]) differed from those of the US probably benign (2.8% [2/72]) (p = 0.002) and US suspicious LNs (78.4% [152/194]) (p < 0.001). Among US indeterminate LNs, there were no significant differences in short, long, and long-to-short diameter (L/S) ratios between benign and metastatic LNs (3.9 vs. 3.8 mm, p = 0.619; 7.3 vs. 7.3 mm, p = 0.590; 1.9 vs. 1.9, p = 0.652). Conclusion: US indeterminate LNs were frequently encountered during preoperative evaluation and had intermediate malignancy risk. Given the lack of discriminative power of size criteria and L/S ratio, clinical factors such as surgical strategy and node size should be considered for proper triage of US indeterminate LNs in thyroid cancer.