• Title/Summary/Keyword: Ultrasonographic imaging

Search Result 105, Processing Time 0.033 seconds

Diagnostic Imaging of Liver Cirrhosis in a Shih-Tzu Dog (시츄견에서 발생한 간경화의 영상 진단)

  • Choi, Ho-Jung;Lee, Ki-Ja;Chang, Jin-Hwa;An, Ji-Young;O, I-Se;Ahn, Se-Joon;Jeong, Seong-Mok;Park, Seong-Jun;Cho, Sung-Whan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.26 no.4
    • /
    • pp.367-370
    • /
    • 2009
  • A 5-year-old, intact female Shih-Tzu dog was presented with 1 year history of icterus, ascites and anorexia. The serum biochemistry revealed elevated liver enzyme levels. Microhepatica and decreased serosal detail were detected in abdominal radiography. Abdominal ultrasonographic findings included irregular liver margins, multifocal hypoechoic nodules in the liver parenchyma, and ascites. Computed tomography (CT) showed multifocal hypodense nodules with ring-like contrast enhancement. Cytologic and histopathologic examination by liver core biopsy revealed fibrosis. Cirrhosis was diagnosed based on above results. This report focuses on the imaging characteristics of ultrasonography and CT for liver cirrhosis in a dog.

Evaluation of Image Quality using ATS-539 Phantom and SNR in the Ultrasonographic Equipment (ATS-539 다목적 팬텀과 SNR을 이용한 초음파 영상평가)

  • Kim, Min-Ju;Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.284-291
    • /
    • 2013
  • The importance of ultrasound examination in the field of medical imaging has been emphasized and the interest in sonographic image evaluation is growing. However image evaluations by the non-standardized criteria and methods, so establishment of legal provisions and objective evaluation criteria are needed. In this study, we used SNR to find out more quantitative way and supplement the limitations of the existing phantom image evaluation. The results of acquired 8 images using ATS-539 multipurpose phantom were compared in SNR of sensitivity and gray-scale dynamic range. In the result of the experiment, excellent equipment of existing phantom images are G1, S1 and G2 in regular sequence. In SNR of sensitivity, G1, S1 and G2 and in SNR of gray-scale dynamic range, S1 G1 and G2 in order. In the conclusion, all the experiment results did not show big difference and regular pattern neither. Therefore, the new evaluation measures should be used with the existing phantom image evaluation method for more objective and quantitative evaluation of the ultrasound imaging device.

Diagnostic Imaging of Lipoma in the Retroperitoneum and Pelvic Cavity in a Dog (개의 후복강과 골반강에 발생한 지방종의 진단영상 증례)

  • Lee, Nam-Soon;Kim, Jun-Young;Na, Eung-Sic;Kim, Mi-Eun;Lee, Hye-Yeon;Choi, Mi-Hyun;Kim, Wan-Hee;Kim, Dae-Yong;Choi, Min-Cheol;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.27 no.1
    • /
    • pp.88-92
    • /
    • 2010
  • An 11-year-old, spayed female, weighing 10 kg miniature Schnauzer was admitted for abdominal distension, anorexia, pollakiuria, and constipation. A large, homogeneous fat opacity mass was identified in the retroperitoneum and pelvic cavity on the abdominal survey radiography. The mass displaced the descending colon peripherally and ventrally, and the urinary bladder ventrally. On the abdominal ultrasonographic examination, the mass was uniformly hyperechoic with a coarse internal echo texture and had outer hyperechoic capsule, and it showed homogeneously same attenuation (-180 ~ -110 HU) as adjacent fat on the computed tomography. There was no evidence of invasion into the surrounding structures or organs. Cytological findings from fine needle aspirates were numerous sheets and clusters of adipocytes. The dog showed complete resolution of clinical signs after surgical resection of the mass. The mass was confirmed as simple lipoma through histopathological examination.

Ultrasonographic Diagnosis of the Patellar Clunk Syndrome after Posterior Stabilized Total Knee Arthroplasty - A Case Report - (후방 안정형 인공 관절 전치환술 후 슬개골 덜컹 증후군의 초음파적 진단 - 증례 보고 -)

  • Yoo, Jae Doo;Kim, Nam Ki;Chung, Jae Yoon
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.39-44
    • /
    • 2014
  • The patellar clunk syndrome is one of the patellofemoral complication, caused by formation of the fibrous nodule at the suprapatellar region after total knee arthroplasty. The symptom involves painful catching, crepitus and clunk during knee extension. It has been mainly but not exclusively associated with the posterior stabilized total knee system. The fibrous nodule is entrapped in the femoral intercondylar notch of the femoral component during flexion and as the knee is extended, it displaces back to the trochlear groove abruptly and the typical symptoms occur. The risk of developing this complication is primarily related to the design of the femoral component and higher incidence was noted with earlier designs of posterior stabilized knee prosthesis. Modifications have been made to the femoral component to optimize the kinematics of the patellofemoral joint and thereby reduced the incidence of patellar clunk syndrome but did not eliminate the problem completely. Clinical examination is the gold standard of diagnosis and imaging study has been used as a possible adjunct to diagnosis. Especially ultrasonography is an imaging modality, which can be easily performed to detect the fibrous nodule on the quadriceps tendon. We report a case of patellar clunk syndrome which was diagnosed with ultrasonography.

  • PDF

Ultrasonographic and Magnetic Resonance Imaging Findings of Testicular Lymphoma (고환림프종의 초음파검사 및 자기공명영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.2
    • /
    • pp.105-112
    • /
    • 2010
  • Purpose : To evaluate the specific radiologic findings of testicular lymphoma which will be able to differentiated from other testicular tumors. Materials and Methods : Pathologically confirmed eight cases were included in this study. All eight cases were performed ultrasonography and four cases were performed magnetic resonance image. On ultrasonography, the size, location, shape, margin, internal echogenicity, homogeneity and vascularity were evaluated. On magnetic resonance image, the shape, margin, homogeneity, signal intensity on T1- and T2-weighted images, degree and homogeneity of the contrast enhancement and contrast enhancement change on dynamic enhancement study. Results : The margin of the mass was smooth on 6 of 8 patients. Internal echogenicity of the mass lesion was hypoechoic than normal testicular parenchyme on 7 of 8 patients. Four cases were homogeneous, 3 cases were relatively homogeneous and 1 case was heterogeneous. All 8 cases showed increased vascularity. The mass lesion was iso-signal intensity on T1-weighted image and low-signal intensity on T2-weighted image. All four cases were enhanced homogeneously and mildly than enhancing normal testicular parenchyme. On dynamic enhancement study, the mass lesion is progressively enhanced with time. Conclusion : The possibility of testicular lymphoma should be considered when testicular mass was homogeneously hypoechoic and low signal intensity on T2-weighted image in old age patients.

  • PDF

Laparoscopic Splenectomy in Two Dogs Using SonicisionTM

  • Park, Tae-Yeong;Kim, Hyun-Jin;Kim, Jung-Hoon;Kim, Jun-Min;Seok, Seong-Hoon;Jung, Dong-In;Hong, Il-Hwa;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.33 no.4
    • /
    • pp.214-217
    • /
    • 2016
  • A 10-year-old, 24.1 kg, intact female Siberian husky dog (case 1) and 11-year-old, 5.0 kg, intact male Shihtzu dog (case 2) presented with chief complaints of polydipsia, anorexia, vomiting and exercise intolerance (case 1) and stranguria (case 2). Splenic nodule (case 1) and mass (case 2) were identified in these patients through ultrasonographic examination. Laparoscopic splenectomy was conducted for the histopathologic evaluation. In addition, laparoscopic ovariohysterectomy, liver biopsy (case 1) and castration (case 2) were performed for treatment or diagnosis of primary symptoms. Under general anesthesia, 5 mm three-portal access laparoscopic splenectomy was performed using the Sonicision$^{TM}$ equipment. The dogs were rotated onto right lateral recumbency. The spleen was elevated using a fan or goldfinger retractor, which revealed the ventral aspect of the spleen. Resection of vessels was started at the caudal aspect of the spleen using the Sonicision$^{TM}$. The excised spleen was removed from the abdominal cavity using a 12 mm endo-bag via the enlarged instrument portal. There were no post-operative complications in either patient. Histopathologic diagnoses were splenic lymphoid hyperplasia (case 1) and splenic nodular hyperplasia (case 2). Based on our experience, laparoscopic splenectomy is sufficient to replace traditional splenectomy in small animal surgery. The use of the Sonicision$^{TM}$ could be a novel surgical technique for three-portal laparoscopic splenectomy, regardless of patient size.

The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom (N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과)

  • Kim, Yon-Min;Shim, Jae-Goo;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.221-225
    • /
    • 2017
  • To evaluate the performance of ultrasound imaging system, we investigated the change of spatial resolution according to changing sonic velocity change parameter provided by ultrasound equipment. Ultrasound phantom images were obtained using a 3.0 ~ 5.0 MHz convex transducer in an ultrasound diagnostic device used at a medical institution located at Iksan. N-365 multi-purpose ultrasound phantom was used to measure longitudinal distance measurement accuracy and longitudinal and transverse resolution. In the same manner, the sonic velocity of the ultrasound equipment was changed from 1580 m/sec to 1400 m/sec in six steps, and the full width at half maximum(FWHM) was measured using the image J program to determine whether the measured values were different. As a result, lateral resolution was measured from 1.91 mm to 5.3 mm according to the speed change, and the smallest FWHM was 1.91 mm at 1420 m/sec. The axial resolution was measured from 1.03 mm to 1.14 mm according to the speed change, and the smallest FWHM was 1.03 mm at 1400 m/sec. The slower the sound velocity of the ultrasound equipment, the shorter the length of longitudinal measurement.

Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies (강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상)

  • Jeong Soon-wuk;Park Hee-myung;Han Sook-hee;Yoon Jung-hee;Han Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

Effects of Diaphragmatic Breathing Training Using Real-time Ultrasonography on Chest Function in Young Females With Limited Chest Mobility (실시간 초음파를 이용한 횡격막 호흡 훈련이 흉곽 가동성 제한이 있는 젊은 여성들의 폐 기능에 미치는 영향)

  • Nam, Soo-jin;Shim, Jae-hun;Oh, Duck-won
    • Physical Therapy Korea
    • /
    • v.24 no.2
    • /
    • pp.27-36
    • /
    • 2017
  • Background: Research efforts to improve the pulmonary function of people with limited chest function have focused on the diaphragmatic ability to control breathing pattern. Real-time ultrasonography is appropriate to demonstrate diaphragmatic mechanism during breathing. Objective: The purpose of this study was to investigate the effects of diaphragmatic breathing training using real-time ultrasonographic imaging (RUSI) on the chest function of young females with limited chest mobility. Methods: Twenty-six subjects with limited chest mobility were randomly allocated to the experimental group (EG) and control group (CG) depending on the use of RUSI during diaphragmatic breathing training, with 13 subjects in each group. For both groups, diaphragmatic breathing training was performed for 30-min, including three 10-min sets with a 1-min rest interval. An extra option for the EG was the use of the RUSI during the training. Outcome measures comprised the diaphragmatic excursion range during quiet and deep breathing, pulmonary function (forced vital capacity; FVC, forced expiratory volume in 1-sec; FEV1, tidal volume; TV, and maximal voluntary ventilation; MVV), and chest circumferences at upper, middle, and lower levels. Results: The between-group comparison revealed that the diaphragmatic excursion range during deep breathing, FVC, and middle and lower chest circumferences were greater at post-test and that the changes between the pretest and post-test values were greater in the EG than in the CG (p<.05). In addition, the subjects in the EG showed increased post-test values for all the variables compared with the pretest values, except for TV and MVV (p<.05). In contrast, the subjects in the CG showed significant improvements for the diaphragmatic excursion range during quiet and deep breathings, FVC, FEV1, and middle and lower chest circumferences after the intervention (p<.05). Conclusion: These results indicate that using RUSI during diaphragmatic breathing training might be more beneficial for people with limited chest mobility than when diaphragmatic breathing training is used alone.

Acute Pancreatitis in Children (소아 급성 췌장염의 임상적 고찰)

  • Cho, Jae-Ho;Lee, Tae-Seok;Ko, Young-Gwan;Oh, Soo-Myung
    • Advances in pediatric surgery
    • /
    • v.2 no.1
    • /
    • pp.17-25
    • /
    • 1996
  • Acute pancreatitis(AP) in children is not common but can be associated with severe morbidity rates and its diagnosis is often delayed. Thus, reported mortality rates range from 0 to 78%. We have treated 26 patients with AP from 5 to 17 years of age over the past 17 years. We are intended to assess the relevance of the prognostic criteria used to assess severity of adult AP and to review the etiology, clilical presentation, diagnosis, and management of AP in children. The authors retrospectively reviewed 26 children with AP managed in Kyung Hee University Hospital from 1978 to 1995. Among 26 patients with AP, male were 12, and female were 14. And the mean age of patients was 11.8 years. In 9(34.6%), no definitive cause was identified. Common causes of AP were trauma(23.1%) and biliary tract disease(23.1%). Other etiologies were viral infection(15.4%) and post ERCP(3.8%). The presenting features were abdominal pain(92.3%), vomiting(61.5%), fever(19.2%), submandibular pain(11.5%), and abdominal mass(7.6%). Back pain was rare(3.8%). Abdominal ultrasonographic findings were abnormal in 10 of 16 patients(62.5%) and abdominal CT findings were abnormal for 9 of 9 patients(100%). Seventeen patients(65.3%) were managed conservatively, and nine patients(34.6%) required surgical treatment. There was no mortality. To evaluate the severity of disease, we used the Imrie prognostic criteria used to assess the severity in adult AP. The number of positive criteria was correlated to the duration of hospitalization(r2=0.91) but statistically insignificant(p>0.05). But, the number of positive criteria was correlated to the operative incidence(r2=0.93) and statistically significant(p<0.05). The common causes of AP in children were unknown origin(34.6%), trauma(23.1%), and biliary tract disease(23.1%). Ultrasonography and computed tomography were useful imaging tools of AP in children. The Imrie criteria used to evaluate the severity in adult AP were suspected to be valuable to assess the severity of AP in children.

  • PDF