• Title/Summary/Keyword: Ultrasonic transducers

Search Result 252, Processing Time 0.022 seconds

Radiation Pattern of the Vibrox Transducer (자외성 페라이트 진동자의 지향특성에 대하여)

  • 신형일
    • Journal of the Korean Institute of Navigation
    • /
    • v.4 no.2
    • /
    • pp.1-6
    • /
    • 1980
  • Computer simulation results on the radiation pattern of an ultrasonic beam by the plurall arrangement of the transducers were reported by Sin (1979). This paper describes on the measurement of radiation pattern in case of one vibrox transducer and two vibrox transducers by varying the interval between the transducers. The measured results obtained are as follows; 1. Radiation wave of ultrasonic transducer is propagated to diffuse with spherical wave from center of transducer. 2. In case of one vibrox transducer, the greater the length of transducer, the sharper becomes the radiation pattern. 3. In case of two vibrox transducers, the maine lobe is revealed at the center of two transducers, it is shown difficult to make control freely of radiation pattern by varying merely the interval of transducers.

  • PDF

Research for Ultrasonic Transducer Manufacturing and Evaluation Technique (초음파탐촉자(超音波探觸子) 제작(製作) 및 평가기술(評價技術)에 관한 연구(硏究))

  • Yoon, K.S.;Huh, H.;Park, D.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.7 no.1
    • /
    • pp.18-31
    • /
    • 1987
  • For the purpose of domestic production of ultrasonic transducer, experiments on material selection for backing and matching layer, and electrical impedance matching between transducer and equipment were performed. The characteristics of manufactured transducers with experimental results were analyzed and compared with foreign products. Through the evaluation of the transducers manufactured and the comparision with foreign products, it is confirmed that the transducers manufactured show the good performance characteristics and efficiency.

  • PDF

Research on the Non-Contact Detection of Internal Defects in a Rail using Ultrasonic Waves (비접촉 초음파 방식의 철도레일 내부결함 검출에 관한 연구)

  • Han, Soon Woo;Cho, Seung Hyun;Kim, Joon Woo;Heo, Tae Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.617-625
    • /
    • 2012
  • Non-contact detection of internal defects in a rail using ultrasonic waves is discussed in this paper. Cracks in a rail may be a cause of a serious railway accident such as derailment if left undetected. Concurrent rail inspection method based on ultrasonic testing using piezoelectric transducers has several limitations as it should keep physical contact with the rail. This work suggests a non-contact detection of internal defects in a rail using ElectroMagnetic Acoustic Transducers (EMAT) which can produce and measure ultrasonic waves in a rail without any couplant. The EMATs for rail inspection are designed and fabricated and their working performance is verified through a series of experiments on various types of internal defects in test rails. The effect of lift-off between the transducers and the rail on the generated signals is also discussed.

  • PDF

Determination of the Vertical Crack Depth in Concrete by the Ultrasonic Time of Flight (초음파 도달시간에 의한 콘크리트에서의 수직 균열의 깊이 측정에 관한 연구)

  • 김영환;이세경;김호철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.04a
    • /
    • pp.35-38
    • /
    • 1990
  • Depths of the vertical cracks in the concrete were determined by the time of flight of the ultrasonic waves. The ultrasonic waves are diffracted at the crack tip, and the arrival time of ultrasonic waves are dependent on the crack depth and speration distance between transmitting and receiving ultrasonic transducers. The vertical cracks with 0.2-2mm width and 10-100mm depth were examined by multi-layered ultrasonic transducers. It was found that the time of flight of ultrasonic waves were proportional to the depth of vertical cracks. The depth of vertical cracks in the range of 20-100mm depth could be determined by the transient time of the diffracted ultrasonic waves

  • PDF

Design and Fabrication of Magnetostrictive Transducers for Scanning OPMT Development (주사형 OPMT 개발을 위한 자왜형 초음파 변환기 설계 및 제작)

  • Lee, Ho-Cheol;Kim, Hyeng-Yoon;Kim, Y.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.856-859
    • /
    • 2005
  • The OPMT(Orientation-adjustable Patch-type Magnetostrictive Transducer) was proposed as a tool for generating and measuring the ultrasonic Lamb wave in plate type structures. This sensor has a lot of new features compared to the traditional piezo-type ultrasonic transducers. As an example, it does not need any kind of wiring for lunching or measuring ultrasonic waves. But it has also definite limitation for practical usage as a nondestructive testing tool in that it cannot help rotating the direction of ultrasonic wave manually. The idea for 'scanning OPMT' is proposed in this respect. Two kinds of basic ideas for rotating the wave direction not manually but electrically are proposed. The fabrication of the transducer and the testing for Identifying the primary characteristics are done for one of the proposed transducers. The results says that there are the possibilities as a new tool for NDE in that the proposed transducer follows well the characteristics of the traditional OPMT. But there are also the 1imitations to overcome.

  • PDF

Influence of Ultrasonic Waves on the Stacking Orientation in Carbon Fiber/Epoxy Composite Laminates

  • Park, Je-Woong;Kim, Do-Jung;Hsu, David K.;Seo, Young-Hwan;Im, Kwang-Hee
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.8-13
    • /
    • 2008
  • In this study, an investigation of shear wave ultrasonic technique was carried out to detect stacking orientation error for CF/Epoxy quasi-isotropy composite laminates. The ultrasonic shear wave is particularly sensitive to ply orientation and layup sequence in tire CF/Epoxy composite laminates. In the manufacturing of composite laminates, it is important that layup errors be detected in samples. In this work, an effect was mack to develop shear wave techniques that can be applied to composite laminates. During testing, the mast significant problem is that the couplant conditions do not remain the same because of its changing viscosity. The design and use of a shear ware transducer would greatly alleviate the couplant problem. A pyramid of aluminum, with isosceles triangle (two 45o angles) sides, was made to generate shear waves, using two longitudinal transducers based on an ultrasonic-polarized mechanism. A signal splitter was connected to the pulser jack on a pulser/receiver and to the longitudinal transducers. The longitudinal transducers were mounted with mineral oil, and the shear transducer was mounted with burnt honey on the bottom as a receiver. The shear wave was generated at a maximum and a minimum based on the ultrasonic-polarized mechanism. Results show it is feasible to measure layup error using shear wave transducers on a stacking of prepregs in composites.

Use of Time Reversal Techniques for Focusing of Ultrasonic Array Transducer Beams

  • Kim, Hak-Joon;Song, Sung-Jin;Thompson R. Bruce;Kim, Jae-Hee;Eom, Heung-Sup
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.3
    • /
    • pp.190-197
    • /
    • 2006
  • For enhancement of flaw detactability using array transducers, focusing of ultrasonic waves on a target in an inhomogeneous medium or through a complex geometry is important. But focusing can be strongly degraded by geometrical distortion of field radiated by the array transducers or by sound speed fluctuations in the propagating medium. In recent years, the time reversal technique has been proposed. Thus, in this paper, we describe the basic principal of the time reversal technique for focusing. Then, the implementation results of the time reversal technique for ultrasonic inspections using bulk waves and guided waves generated by array transducers are presented.

Optimum Directivity Synthesis of Ultrasonic Transducers Using Direct Inversion in Combination with Iterative DFP Method

  • K. R. Cho;Kim, C. D.;T. Tsuchiya;Y. Kagawa
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.10a
    • /
    • pp.477-483
    • /
    • 2001
  • Optimum directivity synthesis of ultrasonic transducers in linear array is considered. To realize the desired directivity, a robust and efficient method is proposed which is the direct inversion combined with the iterative DFP (Davidon-Fletcher-Powell) method. A quasi-ideal beam with the beam width and the steering beam angle specified are chosen for the numerical demonstrations. The demonstration is then extended to the case of multi-beams. The proposed combination method shows quick convergence over the single LMS or DFP method at the expense of the system matrix inversion.

  • PDF

Ultrasonic Sensors for Steel Structure Inspection (강구조물(鋼構造物) 진단(診斷)을 위한 초음파(超音波) 센서)

  • Shin, Byoung-Churl
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.2
    • /
    • pp.170-176
    • /
    • 1998
  • The team mixed PbO, $ZrO_2$, $TiO_2$, $Nb_2O_5$ and $MnCO_3$, to make $Pb[(Zr_{0.54}\;Ti_{0.46})\;Nb_{0.005}]O_3+4%MnCO_3$. The electroded PZT ceramics were poled by 3 kV/mm at $110^{\circ}C$ for 600 s. We assembled the 0.4mm thick PZT slices into ultrasonic transducers. Central frequency of the probe is 5 MHz, which is proper to the thickness gauge for steel pipes and for flaw detector. The probe can detect a disk shape defect of 1mm diameter at 15cm deep in steel block. The new probe's Fresnel zone that the ultrasonic beam do not broaden is 13mm. Over the Fresnel zone, the ultrasonic beam spreads. Half of the beam spread angle of the probe is $4.3^{\circ}-4.6^{\circ}$. This probe can be used for the ultrasonic transducers for non-destructive testing of steel bridges.

  • PDF

Development and Application of Phased Array System for Defect Imaging in Plate-like Structures (평판 구조물의 영상화를 위한 위상 배열 시스템 개발 및 응용)

  • Lee, Joo Kyung;Kwon, Young Eui;Lee, Heung Son;Seung, Hong Min;Kim, Ki Yeon;Lee, Jun Kyu;Kim, Hoe Woong;Lee, Ho Cheol;Kim, Yoon Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.2
    • /
    • pp.123-130
    • /
    • 2014
  • An ultrasonic magnetostrictive transducer-based phased-array system for imaging defects in plate structures is newly proposed. In that most ultrasonic phased array systems rely on piezoelectric transducers or electromagnetic acoustic transducers, this system has its own unique feature of employing magnetostrictive transducers. Interest in using a phased array system using magnetostrictive transducers has been recently reported for pipe inspection but no such system has been developed for plate inspection. In this investigation, we aim to propose a phased array system using OL-MPTs (Omnidirectional Lamb wave Magnetostrictive Patch Transducers) for plate inspection. The developed system consists of a multi-channel function generator, power amplifiers, preamplifiers and a data acquisition unit. In the process of its development, each of the units must be checked and in doing so, we suggest types of ultrasonic wave experiments that should be carried out. Finally, the phased system using a transducer array composed of eight OL-MPTs is newly configured and is applied for actual crack detection experiments.