Design of piezoelectric micro-machined ultrasonic transducer for wideband ultasonic radiation in air (공기 중 광대역 초음파 방사용 압전 박막 기반 초소형 초음파 트랜스듀서의 설계)

  • Ahn, Hongmin;Jin, JaeHyeok;Moon, Wonkyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.2
    • /
    • pp.87-97
    • /
    • 2020
  • In this paper, the design of piezoelectric Micro-machined Ultrasonic Transducer (pMUT) for wideband ultrasonic radiation in air was investigated. One of the methods to achieve wide frequency bandwidth in single device is modeling the transducer to multi-resonance system. The new pMUT was designed as a multi-resonance system with the addition of a suitable acoustic structure to the front and back of a thin film structure. A new pMUT consisting of thin film parts, radiation parts, and packaging parts is designed with a Lumped Parameter Model (L.P.M). Finally, it was validated as a Finite Element Method (FEM) simulation. The final designed pMUT achieved a frequency band of 102 kHz ~ 132 kHz (-3 dB).

Study on 3-D Physical Modeling for the Inspection of Tunnel Lining Structure by using Ultrasonic Reflection Method (터널 지보구조 진단을 위한 초음파 반사법을 이용한 3차원 모형실험 연구)

  • 김중열;김유성;신용석;현혜자
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.221-228
    • /
    • 2002
  • Thickness of concrete lining, voids at the back of lining or shotcrete are very important elements for inspecting the safety of tunnels. Therefore, the inspection of tunnel lining structure means to investigate the inner layer boundaries of the structure. For this purpose, seismic reflection survey is the most desirable method if it works in good conditions. However, the conventional seismic reflection method can not be properly used for investigating thin layers in the lining structure. In other words, to detect the inner boundaries, it is desirable for the wavelength of source to be less than the thickness of each layer and for the receiver to be capable of detecting high frequency(ultrasonic) signals. To this end, new appropriate source and receiver devices should be developed above all for the ultrasonic reflection survey. This paper deals primarily with the development of source and receiver devices which are essential parts of field measuring system. Interests are above all centered in both the radiation pattern, energy, frequency content of the source and the directional sensitivity of the receiver. With these newly devised ones, ultrasonic physical modeling has been performed on 3-D physical model composed of bakelite, water-proof and concrete, The measured seismograms showed a clear separation of wave arrivals reflected from each layer boundary. Furthermore, it is noteworthy that reflection events from the bottom of concrete below water-proof could be also observed. This result demonstrates the usefulness of the both devices that can be applied to benefit the ultrasonic reflection survey. Future research is being focus on dealing with at first an optimal configuration of source and receiver devices well coupled to tunnel wall, and further an efficient data control system of practical use.

  • PDF

A Study of the Acoustic Microscope System by Large Aperture Probe (대구경 탐촉자를 이용한 초음파 현미경 시스템 연구)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.5
    • /
    • pp.475-479
    • /
    • 2003
  • Traditional ultrasonic evaluation to detect micro/small surface cracks is the pulse-echo technique using the normal immersion transducer with high frequency, or the angle beam transducer with surface wave. It is difficult to make the automatic ultrasonic system that is to detect micro and small surface crack and position on the large structure like steel and ceramic rolls, because of the huge data of inspection and the ambiguous position data of transducer. The aim of this study using the high precision scanning acoustic microscope with 10MHz large aperture transducer was to display the real time A, B, C-scan for the automatic ultrasonic system in order to detect the existence and position of surface crack. The ultrasonic method with large aperture transducer was improved the scanning time and speed over 10times faster than traditional methods.

Quantification of Pre-parturition Restlessness in Crated Sows Using Ultrasonic Measurement

  • Wang, J.S.;Huang, Y.S.;Wu, M.C.;Lai, Y.Y.;Chang, H.L.;Young, M.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.6
    • /
    • pp.780-786
    • /
    • 2005
  • This study presents a non-video, non-invasive, automatic, on-site monitoring system the system employs ultrasonic transducers to detect behavior in sows before, during and after parturition. An ultrasonic transmitting/receiving (T/R) circuit of 40 kHz was mounted above a conventional parturition bed. The T/R units use ultrasonic time-of-flight (TOF) ranging technology to measure the height of the confined sows at eight predetermined locations. From this data, three momentary postures of the sow are determined, characterized as standing-posture (SP), lateral-lying-posture (LLP) and sitting posture (STP). By examining the frequencies of position switch Stand-Up-Sequence (SUS) between standing-posture (SP), lateral-lying-posture (LLP) and sitting-posture (STP) rate can be determined for the duration of the sow' confinement. Three experimental pureblooded Landrace sows undergoing normal gestation were monitored for the duration of confinement. In agreement with common observation, the sows exhibited increased restlessness as parturition approached. Analysis of the data collected in our study showed a distinct peak in Stand-Up-Sequence (SUS, i.e. the transition from lying laterally to standing up ) and sitting-posture (STP) rate approximately 12 h prior to parturition, the observed peak being 5 to 10 times higher than observed on any other measurement day. It is concluded that the presented methodology is a robust, low-cost, lowlabor method for the continuous remote monitoring of sows and similar large animals for parturition and other behavior. It is suggested that the system could be applied to automatic prediction of sow parturition, with automatic notification of remote management personnel so human attendance at birth could reduce rates of sow and piglet mortality. The results of this study provide a good basis for enhancing automation and reducing costs in large-scale sow husbandry and have applications in the testing of various large mammals for the effects of medications, diets, genetic modifications and environmental factors.

Development of Automatic Ultrasonic Testing Techniques of Low Pressure Turbine Blade of Nuclear Power Plants (원자력 발전소 저압 터빈 동익 자동 초음파 검사 기술 개발)

  • Yang, Seung-Han;Lee, Jeong-Bin;Kim, Young-Ho;Yoon, Byung-Sik;Kim, Yong-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.371-377
    • /
    • 2004
  • As the turbine running duration in nuclear power plants increases, cracks have been found in the pin finger type blade root area. The nondestructive examination for the blade root area has been carried out by manual ultrasonic examination during the overhaul period, but because of necessity to improve the reliability, we developed an automatic ultrasonic examination system and technique. To demonstrate the performance of the developed automatic ultrasonic examination system, low pressure turbine blades in the 2nd and 3rd stages of nuclear power plants were examined using the developed system. Its applicability nuclear power plant turbine roots of various types was also confirmed.

식물세포의 관류배양을 위한 초음파 분리기의 개발

  • Gu, Yeong-Han;Jo, Gyu-Heon
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.402-404
    • /
    • 2000
  • In this study, we have developed an ultrasonic separation system for plant cells and its operating conditions in terms of voltage, flow rate and concentration were examined. For plant cell, the operation of ultrasonic separator highly depended on concentration of cells. Holding capacity highly depended on flow rate in chamber. Optimum voltage was 30V in high density culture

  • PDF