• 제목/요약/키워드: Ultrasonic system

검색결과 1,517건 처리시간 0.024초

초음파 여기를 이용한 물체 이송 시스템 개발에 관한 연구 (Development of the Object Transport System using Ultrasonic Wave Excitation)

  • 정상화;신병수;차경래;송석;이경형
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.371-375
    • /
    • 2003
  • In recent years, as the semiconductor and the optical industry grows, the necessity of the transporting system for semiconductor and precision optical lens without damage increases. The transport system using ultrasonic wave is very suitable for this area. In this paper the object transport system using the excitation of ultrasonic wave is proposed. The experiments for finding the optimal excitation frequency, finding phase-difference between two ultrasonic wave generators are performed. The effect of transporting speed according to the change of weight and amplification voltage are verified. In addition, the system performance for actual use is evaluated.

  • PDF

DEVELOPMENT OF AN INTELLIGENT ULTRASONIC EVALUATION SYSTEM WITH A MULTI-AXIS PORTABLE SCANNER

  • Sung-Jin Song;Hak-Joon Kim;Won-Suk Sung
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 1996년도 제7회 학술강연회논문집
    • /
    • pp.167-176
    • /
    • 1996
  • Flaw classification and sizing are very essential issues in quantitative ultrasonic nondestructive evaluation of various materials and structures including weldments. For performing of these tasks in an automated fashion, we are developing an intelligent ultrasonic evaluation system with a multi-axis portable scanner which can do consistent and efficient acquisition and processing of ultrasonic flaw signals. Here we present our efforts to develop of this intelligent system including design of the portable scanner, acquisition and processing of ultrasonic flaw signals, display of pseudo 3-D image of flaws, and classification and sizing of flaws in weldments.

  • PDF

초음파센서를 이용한 하천 수위/유속 측정 시스템 (River level/velocimetry measuring system using the ultrasonic sensor)

  • 박희석;박찬원
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.249-255
    • /
    • 2006
  • In this paper, we study the river level/velocimetry measuring system using the ultrasonic sensor to acquire the more precise data from the river circumstance in rainy season. We design the two ultrasonic sensor system to calculate the water level and surface current speed of the river using the dedicated hardware and software. We investigate the validity and effectiveness of the proposed system which applied to the real river environment monitoring system that will be extended to the GIS.

  • PDF

자동 초음파 검사를 위한 결함 영상 처리 시스템의 설계 및 구현 (Design and Implementation of Flaw Image processing System for Automated Ultrasonic Testing System)

  • 김한종;박종훈;김철원
    • 한국정보통신학회논문지
    • /
    • 제14권1호
    • /
    • pp.225-232
    • /
    • 2010
  • 용접부 내에 존재하는 결함의 형태, 위치, 크기 등의 정보를 정량적으로 파악하기 위하여 초음파 탐상 검사가 많이 활용되는데, 최근 들어 용접부의 결함 탐상을 위해, 검사과정을 기계적 스캐너로 자동화한 자동 초음파 탐상 시스템이 많은 산업 분야에서 활용되고 있고, 특히 배관 용접부의 건전성 평가를 위한 비파괴안전진단에서 그 활용 폭이 커지고 있다. 본 논문에서는 배관 용접부의 자동 초음파 검사를 위한 알고리즘 구현과 결함 영상을 보정하여 주는 결함영상 처리 시스템을 설계 및 구현하였다. 적용된 기법으로는 초음파 A-Scan 압축 알고리즘, Synthetic Aperture Focusing 알고리즘, 결함영상증폭 알고리즘과 이와 관련된 소프트웨어 설계 및 구현에 대하여 논한다.

5MHz 초과 초음파자극기에 대한 IEC 61689 규격 적용의 유효성에 관한 연구 (A Study on Effectiveness of Application of the IEC 61689 Standard to Ultrasonic Physiotherapy Systems with Frequency Range over 5MHz)

  • 윤주신;최기상
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권3호
    • /
    • pp.69-78
    • /
    • 2015
  • Ultrasonic physiotherapy systems should comply with IEC 60601-2-5(particular requirements for safety of ultrasonic physiotherapy equipment) standard for safety of patients and clinical performances. One of the most important parameters in the standard is the effective radiating area ($A_{ER}$). It has to be measured in accordance with IEC 61689 (field specifications and methods of measurement in the frequency range 0.5MHz to 5MHz). Typical ultrasonic physiotherapy system works in the frequency range 1MHz ~ 3MHz to comply with the IEC 61689. However, ultrasonic physiotherapy system using frequencies over 5MHz is out of the IEC 61689's scope. That is, even if such ultrasonic physiotherapy systems are developed by demands of the market, there is no standard to apply. It is the motivation for this study. Whereas there are other parameters to be considered, this study focuses on the effective radiating area and shows effectiveness of applying IEC 61689 in measuring effective radiating area of ultrasonic physiotherapy systems using frequency range over 5MHz by comparing the results of computer simulation and experiment. Results of this study shows that applying the IEC 61689 standard to ultrasonic physiotherapy system using frequency range over 5MHz is possible.

압전 초음파 전동기의 토크측정 시스템 (Torque Measurement System of Piezoelectric Ultrasonic Motor)

  • 김영균;김진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1780-1782
    • /
    • 1999
  • The ultrasonic motor used here is the windmill type ultrasonic motor operated by single-phase AC source. A metal-ceramic composite component was used as the stator element to generate ultrasonic vibrations. The windmill type ultrasonic motors has only three components; a stator element of two wind-mill shape slotted metal endcaps, a rotor and a bearing. In this paper we proposed a system for torque measurement of piezoelectric ultrasonic motor.

  • PDF

초음파를 이용한 발전용 회전기기 베어링 손상상태 평가 연구 (A Study on Damage Evaluation of Bearings for Rotating Machinery in Power Plant Using Ultrasonic Wave)

  • 이상국;이선기;이도환;박성근
    • 대한기계학회논문집A
    • /
    • 제32권7호
    • /
    • pp.583-589
    • /
    • 2008
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established. Bearing diagnosis system is composed of four parts as follows : sensing part for ultrasonic sensor and preamplifier, signal processing part for measuring frequency spectrum, energy and amplitude, interface part for connecting ultrasonic signal to PC using A/D converter, graphic display and software part for display of bearing condition and for managing of diagnosis program.

Zynq-SoC를 이용한 초음파 위치추적 시스템 (An Ultrasonic Positioning System Using Zynq SoC)

  • 강문호
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1250-1256
    • /
    • 2017
  • In this research, a high-performance ultrasonic positioning system is proposed to track the positions of an indoor mobile object. Composed of an ultrasonic sender (mobile object) and a receiver (anchor), the system employs three ultrasonic time-off-flights (TOFs) and trilateration to estimate the positions of the object with an accuracy of sub-centimeter. On the other hand, because ultrasonic waves are interfered by temperature, wind and various obstacles obstructing the propagation while propagating in air, ultrasonic pulse debounce technique and Kalman filter were applied to TOF and position calculation, respectively, to compensate for the interference and to obtain more accurate moving object position. To perform tasks in real time, ultrasonic signals are processed full-digitally with a Zynq SoC, and as a software design tool, Vivado IDE(integrated design environment) is used to design the whole signal processing system in hierarchical block diagrams. And, a hardware/software co-design is implemented, where the digital circuit portion is designed in the Zynq's fpga and the software portion is c-coded in the Zynq's processors by using the baremetal multiprocessing scheme in which the c-codes are distributed to dual-core processors, cpu0 and cpu1. To verify the usefulness of the proposed system, experiments were performed and the results were analyzed, and it was confirmed that the moving object could be tracked with accuracy of sub-cm.

유비쿼터스 컴퓨팅의 실내 측위 기술을 위한 U-SAT 시스템의 적용에 관한 연구 (A Study on the Application of U-SAT System for the Indoor Positioning Technology of Ubiquitous Computing)

  • 이동활;박종진;김수용;문영성;이만형
    • 제어로봇시스템학회논문지
    • /
    • 제12권9호
    • /
    • pp.876-882
    • /
    • 2006
  • This study presents an ultrasonic location awareness system for the ubiquitous computing with absolute position. The flight time of ultrasonic waves is determined by a period detecting technique which is able to extend the sensing range compared with traditional methods. For location awareness, ultrasonic waves are sent successively from each ultrasonic transmitter and synchronized by radio frequency (RF) signal, where the transmitting part is fixed and the receiving part is movable. To expand the recognizing range, cell matching technique and coded ultrasonic technique are introduced. The experimentation for various distances is accomplished to verify the used period detecting technique of U-SAT system. The positioning accuracy by using cell matching is also verified by finding the locations of settled points and the usability of coded ultrasonic technique is verified. As a result, the possibility of ultrasonic location awareness system for the ubiquitous computing can be discussed as a pseudo-satellite system with low cost, a high update rate, and relatively high precision, in the places where CPS is not available.

초음파 연료분사장치용 디젤자동차의 성능향상에 관한 연구(II)-분무특성과 기관성능에 대하여- (A Study on the Performance Improvement of Diesel Automobile Engine with Ultrasonic Fuel Feeding System(II)-On the Spray Characteristics and Engine Performance-)

  • 양정규;정진도;류정인
    • 한국자동차공학회논문집
    • /
    • 제2권6호
    • /
    • pp.50-56
    • /
    • 1994
  • This is an experimental study on the performance characteristics of Diesel Automobile with ultrasonic fuel feeding system. For this purpose, ultrasonic fuel feeding system was made and atomization characteristics was measured. Base on this result, carried out engine dynamometer test to investigate the performance characteristics of diesel automobile with ultrasonic fuel feeding system in comparison with conventional diesel fuel injector. The results are as follows. 1) In the spray characteristics test, fuel particle sizes were decreased about 11%~21%. 2) In engine dynamometer test, -The power was increased about 5%~11%. -The thermal efficiency was improved about 6%~11%. -The specific fuel consumption was improved about 6%~19%. -The smoke concentration was decreased about 11%~50%.

  • PDF