• Title/Summary/Keyword: Ultrasonic probe

Search Result 160, Processing Time 0.024 seconds

PAUT-based defect detection method for submarine pressure hulls

  • Jung, Min-jae;Park, Byeong-cheol;Bae, Jeong-hoon;Shin, Sung-chul
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.2
    • /
    • pp.153-169
    • /
    • 2018
  • A submarine has a pressure hull that can withstand high hydraulic pressure and therefore, requires the use of highly advanced shipbuilding technology. When producing a pressure hull, periodic inspection, repair, and maintenance are conducted to maintain its soundness. Of the maintenance methods, Non-Destructive Testing (NDT) is the most effective, because it does not damage the target but sustains its original form and function while inspecting internal and external defects. The NDT process to detect defects in the welded parts of the submarine is applied through Magnetic particle Testing (MT) to detect surface defects and Ultrasonic Testing (UT) and Radiography Testing (RT) to detect internal defects. In comparison with RT, UT encounters difficulties in distinguishing the types of defects, can yield different results depending on the skills of the inspector, and stores no inspection record. At the same time, the use of RT gives rise to issues related to worker safety due to radiation exposure. RT is also difficult to apply from the perspectives of the manufacturing of the submarine and economic feasibility. Therefore, in this study, the Phased Array Ultrasonic Testing (PAUT) method was applied to propose an inspection method that can address the above disadvantages by designing a probe to enhance the precision of detection of hull defects and the reliability of calculations of defect size.

A Study on Pulse Pattern Using Ultrasonic Device (초음파기기를 이용한 맥상(脈象) 연구)

  • Kim, Hee Young;Park, Jeongbin;Keum, Yujeong;Yeo, Inkeum;Eom, Dongmyung;Song, Jichung
    • Journal of Korean Medical classics
    • /
    • v.34 no.2
    • /
    • pp.85-94
    • /
    • 2021
  • Objectives : Pulse diagnosis is one of the main diagnostic methods of Korean Medicine that understands the patient's condition and illness by reading changes in the patient's pulse, which is described in terms of pulse condition While they are described in detail in medical texts, it is difficult to grasp their true nature, as the written descriptions fail to do justice to the experience of pulse taking it tries to convey. As a way to approach pulse condition the effect of the body's tension on the radial vein was measured using an ultrasonic device, after which the measured changes and how they could be reflected in pulse condition were studied. In other words, changes in the radial vein following induced tension were analyzed. Methods : 1) The thickness of the subject's radial vein was measured using a linear probe of an ultrasonic device[LOGIQ 5 Basic, GE, USA]. 2) Fatigue level was increased through artificial stimulation using the Gripmeter[ks-301, Lavisen, Korea]. 3) Thickness of the radial vein post tension induction was measured. 4) The results were analyzed with the Tukey test or paired t-test as post hoc tests. Results : Thickness of the radial vein of the subject pre- and post- Gripmeter stimulation decreased with significance. Conclusions : Constriction of the radial vein that happened after tension induction could be linked to the Tight Pulse[緊脈] that is related to patterns of contraction and pulling.

A Convergence Study on the Measurement of Bacterial Pollution in Medical Ultrasonic Practice (의료용 초음파 실습 시 장치의 세균오염도 측정에 관한 융합적 연구)

  • Kim, Dong-Heun;Park, Sang-Hee;Park, Gyu-Tae;Jung, Won-Hee;Kim, So-Yeon;Hong, Hee-Jin;Son, Na-Ra;Nam, Seoul-Hee;Han, Man-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.10
    • /
    • pp.75-80
    • /
    • 2019
  • During the medical ultrasound exercise at school, we randomly select parts of the ultrasound device and areas with the most contact in the abdominal phantom to detect bacteria that are above the probe and determine the number of pathogens. I want to find out. The experimental method was rubbed 20 times with the sterilized cotton swab for sterilization and then smeared on Lysogeny broth (LB) agar, put into the incubator and incubated for 48 hours, and the colony forming unit (CFU) count was measured. The bacterial distribution of probe handle and abdominal phantom was evaluated by evaluation. As a result, the CFU value is the lens was $3.0{\pm}0.87$, print button was $5.5{\pm}1.06$, freeze button was $8.0{\pm}4.95$, phantom was $20.0{\pm}2.78$, line was $23.5{\pm}2.50$, and probe handle was measured as $35.3{\pm}10.75$. In this study, it is expected that attention to infection control of equipment during practice during medical ultrasound practice can be highlighted and further contributed to the reduction of bacterial infection rate of ultrasound devices.

Development of Calibration System for Contact Transducer (초음파 탐촉자의 교정 시스템 개발)

  • Nam, Y.H.;Seong, U.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.4
    • /
    • pp.294-299
    • /
    • 1999
  • In this paper, the calibration system for contact transducer has been developed to improve the reliability of the inspection result of ultrasonic testing on rotors. This system consists of signal processing parts: (oscilloscope, spectrum analyzer, pulser/receiver), standard block, and user interface program. Signal processing for the calibration system was performed quickly with high accuracy. The developed system has been applied to a practical calibration of probe using the non-destructive testing on rotors, and demonstrated high sensitivity and precision.

  • PDF

A Study on Development of Automatically Recognizable System in Types of Welding Flaws by Neural Network (신경회로망에 의한 용접 결함 종류의 정량적인 자동인식 시스템 개발에 관한 연구)

  • 김재열
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.1
    • /
    • pp.27-33
    • /
    • 1997
  • A neural network approach has been developed to determine the depth of a surface breaking crack in a steel plate from ultrasonic backscattering data. The network is trained by the use of feedforward three-layered network together with a back-scattering algorithm for error correction. The signal used for crack insonification is a mode converted 70$^{\circ}$transverse wave. A numerical analysis of back scattered field is carried out based on elastic wave theory, by the use of the boundary element method. The numerical data are calibrated by comparison with experimental data. The numerical analysis provides synthetic data for the training of the network. The training data have been calculated for cracks with specified increments of the crack depth. The performance of the network has been tested on other synthetic data and experimental data which are different from the training data.

  • PDF

A Study on Highly Accurate Evaluation Technique using Ultrasonic Spectrum Analysis Method (초음파스펙트럼해석법을 이용한 고정도 결함평가)

  • 노승남
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.2
    • /
    • pp.76-82
    • /
    • 1997
  • The discrimination of flaw shape and sizing is very important subject in the material evaluation for semiconductor and new materials. The aim of this paper is to investigate the spectrum analysis of artificial defect signal captured from steel ball embedded in the resin. The results show that it can be evaluated quantitatively the size of artificial defect, from the amplitude variation of same frequency if the probe with same diameter and focal length is used. Comparing with the amplitude variation of the high frequency component and low frequency component obtained from the distance of defect center position, it can be estimated steel ball and flat bottm defect.

  • PDF

Study of Self Texturing on ZnO:Al TCO surface for Thin-Film Solar Cell (박막태양전지용 ZnO:Al 투명전도막 표면 Self-Texturing 연구)

  • Oh, Kyoung Suk;Yoon, Soon Gil;Lee, Jeong Chul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.127.2-127.2
    • /
    • 2011
  • 본 연구에서는 RF Magnetron Sputtering System을 이용하여 ZnO계 투명전도막 증착시 Vaporization된 MeOH를 유입함으로써 박막증착과 동시에 표면의 Roughness를 제어하여 이에따른 전기적 특성 및 광학적 특성의 개선에 대하여 연구하였다. 실험방법으로 기존의 RF Magnetron Sputtering System에 Vaporization이 가능한 Ultrasonic을 이용하여 MeOH를 Vaporized시켜 MFC Controll을 통해 챔버에 유입하여 ZnO계 투명전도막의 박막증착과 동시에 표면 Texturing을 하였다. ZnO계 투명전도막의 박막증착시 Vaporized MeOH의 유입에 따른 광학적 특성변화를 UV-visible-nIR spectrometry로 조사하였으며, 전기적 특성 변화를 4-Point-Probe로 조사하였으며, 표면적 특성 변화를 Atomic Force Microscope(AFM), Scanning Electron Microscopy(SEM)를 조사하였으며, 박막의 결정성장특성 변화를 X-ray Diffraction(XRD)으로 조사하였으며, Vaporized MeOH 유입에 따른 박막의 성분분석을 Secondary Ion Mass Spectrometry (SIMS)로 조사함으로써 최적의 조건 및 공정을 확립하였다.

  • PDF

Systems Engineering Method to Develop Multiple BMI Nozzle Inspection System for APR1400

  • Abdallah, Khaled Atya Ahmed;Nam, GungIhn
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.12 no.1
    • /
    • pp.25-40
    • /
    • 2016
  • The Systems Engineering (SE) approach is characterized by the application of a structured engineering methodology for the design of a complex system or component. In this study, the SE methodology is used to design a nondestructive inspection system for Bottom Mounted Instrumentation (BMI) nozzles. We developed a system that enables nondestructive inspection of BMI nozzles during regular refueling outage without removing the reactor internals. A special ultrasonic (UT) probe is introduced to scan and detect cracks within the weld region of the nozzle. A 3D model of the inspection structure system was developed along with the reactor pressure vessel (RPV) and internals which permits a virtual 3D simulation of the operation to check the design concept and effectiveness of the system and to provide a good visualization of the system. This approach allows for a virtual walk through to verify the proposed BMI nozzle inspection system.

A characteristic study on the transmisson-reception and fabrication of the ultrasonic transducer using composite with 1-3 connectivity (1-3형 복합재료를 이용한 초음파 Transducer의 제작과 송수신 특성연구)

  • Kim, Chan-Young;Lee, Duck-Chool;Kim, Ho-Gi;Kim, Yong-Huck
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.72-74
    • /
    • 1989
  • A composite with 1-3 connectivity was fabricated by filling spurrs epoxy in arried PZT bars. The composite bad lower density(2220 Kg/$m^3$), lower dielectric constant, lower piezoelectric coefficient d33(260*$10^{12}$ C/N), and higher voltage coefficient(110.1*$10^{-3}$ Vm/N) than that of solid PZT. The probe was fabricated by using composite transducer that was made above. The underwater testing of the composite transducer was performed with water backing.

  • PDF

An Implementation of an Infrared System for the 3D Navigator (3차원 Navigator에 적용할 적외선 시스템의 구성)

  • Shin, D.I.;Huh, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.315-316
    • /
    • 1998
  • The purpose of this study is a potentiality examination of an infrared camera system for the 3D navigator which can be used in the field of neurosurgery. Nowadays, CAS(computer aided surgery) technique using 3D navigator is rapidly spread into the neurosurgeric operation such as brain and spine surgery. Several techniques which can detect 3D position of a probe have been proposed. These include mechnical arm, magnetic field, optical and ultrasonic sensing methods. In this study, we decided that using optical sensing method and tested a conventional CCD camera with a infrared filter and LEDs. Pulnix TM-300 camra has sufficient spectral response in the range of near infrared. Acquired image of infrared LEDs also sufficient quality.

  • PDF