• 제목/요약/키워드: Ultrasonic nondestructive test

검색결과 236건 처리시간 0.021초

Studies on the Influence of Various factors in Ultrasonic Flaw Detection in Ferrite Steel Butt Weld Joints

  • Baby, Sony;Balasubramanian, T.;Pardikar, R.J.
    • 비파괴검사학회지
    • /
    • 제23권3호
    • /
    • pp.270-279
    • /
    • 2003
  • Parametric studies have been conducted into the variability of the factors affecting the ultrasonic testing applied to weldments. The influence of ultrasonic equipment, transducer parameters, test technique, job parameters, defect type and characteristics on reliability far defect detection and sizing was investigated by experimentation. The investigation was able to build up substantial bank of information on the reliability of manual ultrasonic method for testing weldments. The major findings of the study separate into two parts, one dealing with correlation between ultrasonic techniques, equipment and defect parameters and inspection performance effectiveness and other with human factors. Defect detection abilities are dependent on the training, experience and proficiency of the UT operators, the equipment used, the effectiveness of procedures and techniques.

초음파 비파괴검사의 신뢰도 평가 모델 (Models of Reliability Assessment of Ultrasonic Nondestructive Inspection)

  • 박익근;박은수;김현묵;박윤원;강석철;최영환;이진호
    • 비파괴검사학회지
    • /
    • 제21권6호
    • /
    • pp.607-611
    • /
    • 2001
  • 초음파검사 시스템은 검사자, 검사장비, 검사절차서로 구성되어진다. 따라서 각각의 구성의 성능에 따라 초음파검사의 신뢰도가 좌우되며, 또한 검사환경이나 검사체의 재질, 결함의 유형에 따라서도 검사의 신뢰도는 영향을 받게된다. 이러한 다양한 인자들로 인해 비파괴검사의 신뢰도를 평가하는 것이 쉽지 않다. 본 연구에서는 로지스틱 모델과 몬테 카를로 시뮬레이션을 이용하여 초음파검사의 신뢰도를 척도할 수 있는 검출확률을 평가하고자 한다. 신뢰도 평가의 유용성을 검증하기 위해 원진배관에 대한 순회시험의 데이터에 신뢰도 평가 모델을 적용하였다.

  • PDF

On Fiber Orientation Characterization of CERP Laminate Layups Using Ultrasonic Azimuthal Scanners

  • Im Kwang-Hee;Hsu, David K.;Sim Jae-Gi;Yang, In-Young;Song, Sung-Jin
    • 비파괴검사학회지
    • /
    • 제23권6호
    • /
    • pp.566-576
    • /
    • 2003
  • Carbon-fiber reinforced plastics (CFRP) composite laminates often possess strong in-plane elastic anisotropy attributable to the fiber orientation and layup sequence. The layup orientation thus greatly influences its properties in a composite laminate. It could result in the part being rejected or discarded if the layup orientation of a ply is misaligned. A nondestructive technique would be very beneficial, which could be used to test the part after curing and to require less time than the optical test. In this paper, ultrasonic scanners were set out for different measurement modalities for acquiring ultrasonic signals as a function of in-plane azimuthal angle. The motorized scanner was built first for making transmission measurements using a pair of normal-incidence shear wave transducers. Another scanner was then built fer the acousto-ultrasonic configuration using contact transducers. A ply-by-ply vector decomposition model has been developed, simplified, and implemented for composite laminates fabricated from unidirectional plies. We have compared the test results with model data. It is found that strong agreement are shown between tests and the model developed in characterizing cured layups of the laminates.

불연속부의 위치를 고려한 초음파 비파괴 검사 규격의 개선안 (Propose of New Ultrasonic Nondestructive Code Considering Discontinuity Position)

  • 정화영;신병철;정범석;이창무
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권4호
    • /
    • pp.173-178
    • /
    • 1999
  • KS-code(KS B 0896) for nondestructive ultrasonic testing classifies the quality level by ratio of flaw size to plate thickness only. But stress distributions using verification(3 point bending test) show that location of the flaws is more important than the flaw size. So. KS-code should take the effect of flaw location for classifying the quality level of welded steel structures.

  • PDF

Correlation Analysis between Ultrasonic Parameters and Elastic Modulus of Apple

  • Kim, Ghi-Seok;Kim, Ki-Bok;Park, Jeong-Gil;Lee, Sang-Dae;Jung, Hyun-Mo;Kim, Man-Soo
    • 비파괴검사학회지
    • /
    • 제28권3호
    • /
    • pp.279-284
    • /
    • 2008
  • The firmness of fruit is one of the most important quality factors and is highly correlated to the elastic modulus. In this study, the ultrasonic transmission method was applied to evaluate the elastic modulus of the apple. In order to transmit and receive the ultrasonic wave through the whole apple, the ultrasonic measurement setup consisted of ultrasonic pulser, two specially fabricated ultrasonic transducers for fruit and digital storage oscilloscope. Ultrasonic parameters such as ultrasonic wave velocity, apparent attenuation, and peak frequencies were analyzed. The elastic modulus of apple was measured by using compression test apparatus. The correlations between ultrasonic parameters and elastic modulus were analyzed. A multiple linear regression model describing the relationship between elastic modulus and ultrasonic parameters was proposed.

Austempered Ductile Cast Irons의 비파괴적 평가 (Nondestructive Evaluation of the Austempered Ductile Cast Irons)

  • 이승석;이세경
    • 비파괴검사학회지
    • /
    • 제9권1호
    • /
    • pp.90-97
    • /
    • 1989
  • Austempered ductile cast iron (ADI) which has been recently developed shows good mechanical properties. These properties are related to the microstructure which is greatly affected by processing variables such as austempering time and temperature. In this study, the relationships between mechanical properties from impact test, and hardness test and the results from ultrasonic velocity measurement and electrical resistivity measurement are studied on the ADI samples which are heattreated at different austempering temperature and time. From the results, we conclude the followings. The ultrasonic velocity measurement could be used for the study of austempering reaction mechanism. The electrical resistivity measurement could be used as quality assurance technique for the ADI.

  • PDF

초음파 비파괴검사의 신뢰도 평가 모델 (Model of Reliability Assessment in Ultrasonic Nondestructive Inspection)

  • 박익근;박은수;김현묵;박윤원;강석철;최영환;이진호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.240-245
    • /
    • 2001
  • Ultrasonic inspection system is consisted of the operator, equipment and procedure. The reliability of results in ultrasonic inspection is affected by its ability. Furthermore, the reliability of nondestructive testing is influenced by the inspection environment, other materials and types of defect. Therefore, it is very difficult to estimate the reliability of NDT due to various factors. In this study, the probability of detection, used logistic probability model and Monte Carlo simulation, estimated the reliability of ultrasonic inspection. The utility of the NDT reliability assesment is verified by the analysis of the data from round robin test applied these models.

  • PDF

공극을 포함한 실리카샌드 시편의 초음파 속도변화 측정 (Measurement of Ultrasonic Wave Velocity Changes in Silica-Sand Specimens with Voids)

  • 김대유;임홍철;조윤진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.48-49
    • /
    • 2017
  • In order to examine the effect of voids on the ultrasonic wave velocity, specimens made of Silica-Sand with voids were prepared for the measurements. The volume fraction of 0, 15, and 30% of voids were used to compare the differences. Because of its more homogeneous distribution of materials properties, the Silica-Sand specimens were used, as compared to mortar specimens. The results showed clear change in ultrasonic wave velocity with different volume fraction of voids. This result is to be used for the estimation of the integrity of concrete structures using ultrasonic wave velocity method as nondestructive testing.

  • PDF

용접부 비파괴 검사의 신뢰성 비교: 화력 발전소의 보일러 수냉벽 배관 사례연구 (Comparative Reliability of Nondestructive Testing for Weld: Water Wall Tube in Thermal Power Plant Boiler Case Study)

  • 최창덕;임익성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제18권3호
    • /
    • pp.240-249
    • /
    • 2018
  • Purpose: The purpose of this research is to find which technique, between the PAUT (Phased array ultrasonic test) that has been used widely in practice and RT (Radiographic test) that was used widely in the past, has the higher reliability as a non-destructive testing of welding points in water wall tubes. Methods: To evaluated the reliability of non-destructive testing, eleven test pieces that were fabricated intentionally, which have the most frequently occurred defect types in water wall tubes and then both the PAUT and RT were performed on those eleven test pieces to compare their reliability. Results: The differences of type of defect, length are occurred due to the characteristics of nondestructive testing. The RT could not detect the lack of fusion defect type in specimen #4 and #8 while PAUT could not detect the lateral crack and 1 mm size small porosity in specimen #11. Conclusion: It is concluded that applying both the RT and PAUT result the best reliability rather than applying only one test method, if it is possible, in nondestructive testing of weld water wall tube in thermal power plant boiler case.

확률론적 방법을 적용한 도로교량의 비파괴 압축강도식 평가 (Comparison Study on Nondestructive Strength Equation Based on Probability for Bridges)

  • 김훈겸
    • 한국도로학회논문집
    • /
    • 제20권3호
    • /
    • pp.39-46
    • /
    • 2018
  • PURPOSES: This study is to estimate nondestructive strength equation based on probability for bridges using field test data. METHODS : In this study, a series of the field inspection and the test have been performed on 297 existing bridges, in order to evaluate the bridges, based on the test results of the in-depth inspection, and the estimated strengths by means of the nondestructive strength equations are analyzed and compared with results of the core specimen strengths. RESULTS : According to results of analyses, In case of standard design compressive strength of concrete is 18MPa, 21MPa, similar reliability of RILEM equation were 0.89~0.90, but in case of standard design compressive strength of concrete is 35MPa, 40MPa were 0.4~0.56. According to standard design compressive strength of concrete is 40MPa, similar reliability of ultrasonic pulse velocity method equation were 0.56. CONCLUSIONS :RILEM equation had high similar reliability than other equation in case of standard design compressive strength of concrete is 18MPa, 21MPa, but had low similar reliability than other equation in case of standard design compressive strength of concrete is 35MPa, 40MPa. and ultrasonic pulse velocity method equation had low similar reliability than other equation in case of standard design compressive strength of concrete is 40MPa.