• Title/Summary/Keyword: Ultrasonic images

Search Result 252, Processing Time 0.019 seconds

Studies on Variation of Characteristics in Hanwoo Steers by Pen and Group Size (한우 거세우의 군집크기에 따른 산육특성 연구)

  • Ha, J.J.;Rhee, Y.J.;Jang, W.J.;Kim, Y.W.;Shaogang, Li;Song, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.1
    • /
    • pp.9-16
    • /
    • 2009
  • This study, tasting 14 months, was conducted to investigate the effects of different pen size and group size on growing-fattening characteristics of Hanwoo steers. Forty-eight, 12-month-old Hanwoo steers($305.8{\pm}32.2\;kg$) were randomly assigned to three groups($35.28\;m^2$; n=4 heads, $70.56\;m^2$; n=8 heads, $105.84\;m^2$; n=12 heads) and reared in separate pens with a constant space allowance of $8.82m^2$ per head from 12 to 21 month of age and then regrouped to 4 heads per pen. A common diet including concentrate(limited) and forage(ad lib) was provided to all the animals. Images of live animal ultrasonic back fat thickness, longissimus muscle area and Marbling score were evaluated in three months interval from 12 months of age using an ultrasound equipment(HS-2000) at the 13th rib and lumber vertebra interface of left side. Significant differences of ADG was found mainly at $15{\sim}18$ month and $18{\sim}21$ month fattening stages(p<0.05). Marbling score(MS) was higher(p<0.05) in 12 heads group when compared with that of 4 and 8 heads groups after 18 months. Animals in 12 heads group had the lowest Average daily gain(ADG) but showed the highest longissimus muscle area(LMA) and marbling score(MS). In addition, Hanwoo steers in 12 heads group obtained a higher quality appearance(HQA) of 82.7% than that of other treatments. The results indicated that Hanwoo steers housed on large group size and pen size decreased their ADG but improved meat quality.

  • PDF

A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom (ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구)

  • Park, Ji Hye;Heo, Yeong Cheol;Kim, Yon min;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.463-472
    • /
    • 2021
  • Demand for examinations using transvaginal transducer with high frequencies is increasing to observe pelvic organs in gynecological ultrasound tests. However, the quality control of the replacement probe in clinical trials is not properly implemented and the evaluation criteria have not been established. Therefore, 58 transvaginal transducers and 20 convex transducers were applied to the ATS-539 ultrasound phantom for 20 ultrasound devices currently in clinical use to obtain their respective images and measure them quantitatively and qualitatively. For quantitative measurements, vertical measurement, horizontal measurement, and focal zone and qualitative measurements, dead zone, axial·lateral resolution, sensitivity, functional resolution, gray scale·dynamic range were performed. Quantitative statistical analysis showed significant differences between the two transducers in the lateral measurement and local area (p<0.05). qualitative comparative analysis showed differences in sensitivity and functional resolution. This occurs due to the difference in frequency between transducers and the transducer's injection geometry. Based on the above experiments, the tolerance for horizontal measurement is raised to 10% (±8 mm), the tolerance for sensitivity is observed up to 6 cm deep, which is 12 cm deep,which is the level of the third quartile (75%). The permissible range of functional resolution is up to 6 (12 cm), 6 (12 cm), 11 (11 cm), 9 (9 cm), 6 (6 cm) target, which is the level of the third quartile (75%). It is considered reasonable to adjust the depth of targets in gray scale·dynamic range to measure at a depth of 2 cm, which is 50% of the depth of 4 cm. As above, the criteria for evaluating the quality of transvaginal transducer for use in the past have been proposed and it is expected that this study will be used as a basic data for the production of phantom exclusively for transvaginal transducer in the future.