• Title/Summary/Keyword: Ultrasonic image

Search Result 414, Processing Time 0.032 seconds

A Study on Ultrasonic Image Diagnosis Methods of Tooth Defect with Phased-Array Techniques (위상배열기법을 이용한 치아결함 초음파이미지 진단기술개발)

  • Oh, Yun-Jung;Hwang, In-Nam;Park, Su-Jung;Im, Kwang-Hee;Cho, Hyun-Joon;Cho, Young-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.604-613
    • /
    • 2009
  • Recently, researches to develop phased array ultrasonic examination techniques are proceeded to diagnose dental caries and the status of surgical operation of dental implant. Sound field analysis of phased array ultrasonic transducers were carried out in order to characterizing the ultrasonic phased array beams. The sound field of ultrasonic radiation was calculated for the sample called "gypsum-improved stone" with the similar characteristics of dental materials. Industrial phased array ultrasonic devices were utilized for the insptriion of the artificial flaws machined in the gypsum-improved stone. Dental implants were made at the pig jaw bone and defect images were confirmed for the dental implants.

  • PDF

2D Image Reconstruction of Bone Using Ultrasound Velocity in Diagnosing Osteoporosis (골다공증 진단에서의 초음파 속도 파라미터를 이용한 2차원 골 영상의 재구성)

  • 김주영;윤세진;최흥호
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.277-280
    • /
    • 2002
  • In this paper, it is fundamental purpose that finding the relationship between quality and structure of bone, by reconstructing the bone structure image, using ultrasound. In this study, longitudinal transmission method was used for experiment as basic measuring method, which is known as ultrasonic diagnosis method for human tibia. And using ultrasonic velocity parameter that can be detected and calculated with the transmitted signal, new estimated parameter, called Bone Area Fraction, is applied to reconstruct image. Through the in-vitro experiment in cattle's tibia bone, basic sectional image of bone which is similar in real bone structure image can be reconstructed.

  • PDF

Image Enhancement Techniques for UT - NDE for Sizing and Detection of Cracks in Narrow Target (초음파 비파괴 평가를 위한 협소 타깃의 크랙 사이징 및 검출을 위한 영상 증진기술)

  • Lee, Young-Seock
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.209-213
    • /
    • 2006
  • In this paper describes image enhancement technique using deconvolution processing for ultrasonic nondestructive testing. . When flaws are detected for B-scan or C-scan, blurring effect which is caused by the moving intervals of transducer degrades the quality of images. In addition, acquisited images suffer form speckle noise which is caused by the ultrasonic components reflected from the grain boundary of material [1,2]. The deconvolution technique can restore sharp peak value or clean image from blurring signal or image. This processing is applied to C-scan image obtained from known specimen. Experimental results show that the deconvolution processing contributes to get improved the quality of C-scan images.

  • PDF

Correlation Analysis between Crack Depth of Concrete and Characteristics of Images (콘크리트 균열 깊이와 이미지 특성정보간의 상관성 분석)

  • Jung, Seo-Young;Yu, Jung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.162-163
    • /
    • 2021
  • Currently, the depth of cracks is measured using ultrasonic detectors in maintenance practice. This method consists of measuring the depth of cracks by attaching ultrasonic depth measuring equipment to the concrete surface, and there are restrictions on the timing and location of the inspection. These limitations can be addressed through the development of image-based crack depth measurement AI technology. If crack depth measurements are made based on images, restrictions on the timing and location of inspections can be lifted because images acquired with simple filming equipment can be used as input information. To efficiently develop these artificial intelligence technologies, it is essential to identify the interrelationship between crack depth measurements and image characteristic information. Thus, this study is a basic study of the development of image-based crack depth measurement AI technology and aims to identify image characteristic information related to crack depth.

  • PDF

Implement for Mobile Robot using the Ultrasonic sensors and the DSP Image Processing (DSP 영상처리와 초음파 센서를 이용한 이동 로봇 구현)

  • 김용준;문철홍
    • Proceedings of the IEEK Conference
    • /
    • 2000.06d
    • /
    • pp.151-154
    • /
    • 2000
  • Standard of implementing a robot is Man, so in many field, Many studies are processing to archive a robot, very similar to human being. This paper, based on the theory of man, implemented on the model of parallelism sense and visual information, which is needed when it's moving. Introduced robot uses CCD and designed Image Processing Board for the purpose of archiving vision data. To keep parallel condition, This use ultrasonic sensors for auto-mobile.

  • PDF

Influence to the Doppler Images by the Defects of SAE in the Probe of Medical Ultrasonic Scanners (초음파 프로브에서 인접 단위 소자군(SAE) 결함이 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.7-15
    • /
    • 2015
  • A ultrasonic probe is very important in medical ultrasonic image, but the frequency of probe defects are often. Therefore practical tools for probe based ultrasonic QA should be developed. Advanced research on the effects of the probe defects on the quality of ultrasonic images is required. This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. Especially the defects in a set of adjacent elements(SAE) electrically disconnected influence Doppler images were tested. The results show Doppler brightness and velocity became rapidly reduced as the defected elements is located centrally, as the defected elements is activated. The more the defected elements increased, the more Doppler brightness and velocity increased. As a set of the element disconnected moved, it appeared Doppler velocity starting to decrease and then was followed by brightness. The strength is not consistent with the velocity in the number and location of the defected elements. The defects in the probe elements influence Doppler velocity when the defected elements got out of the elements activated at Doppler mode.

A Study on the Generation of Ultrasonic Binary Image for Image Segmentation (Image segmentation을 위한 초음파 이진 영상 생성에 관한 연구)

  • Choe, Heung-Ho;Yuk, In-Su
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.6
    • /
    • pp.571-575
    • /
    • 1998
  • One of the most significant features of diagnostic ultrasonic instruments is to provide real time information of the soft tissues movements. Echocardiogram has been widely used for diagnosis of heart diseases since it is able to show real time images of heart valves and walls. However, the currently used ultrasonic images are deteriorated due to presence of speckle noises and image dropout. Therefore, it is very important to develop a new technique which can enhance ultrasonic images. In this study, a technique which extracts enhanced binary images in echocardiograms was proposed. For this purpose, a digital moving image file was made from analog echocardiogram, then it was stored as 8-bit gray-level for each frame. For an efficient image processing, the region containing the heat septum and tricuspid valve was selected as the region of interest(ROI). Image enhancement filters and morphology filters were used to reduce speckle noises in the images. The proposed procedure in this paper resulted in binary images with enhanced contour compared to those form the conventional threshold technique and original image processing technique which can be further implemented for the quantitative analysis of the left ventricular wall motion in echocardiogram by easy detection of the heart wall contours.

  • PDF

A study on growth and development of children by ultrasonic image of calcaneus bone (종골의 초음파영상을 통한 소아성장에 관한 연구)

  • Chang, Gyu-Tae;Kim, Jang-Hyun;Seo, Young-Min
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.1-13
    • /
    • 2003
  • Objectives: The purpose of this study was to suggest a scientific method for measurement of children's growth development. Ultrasonic image of calcaneus bone has some advantages that it is harmless to human body and apply a new imaging analysis algorithm. it can be used for the diagnosis of growth analyzed the opening degree of growth plate and bone density. Methods: This clinical study have been carried out with the 57 case(male 24, female 33) of the children aged 5 to 14 years old who visited in Department of Pediatrics, Dongguk university Bundang Oriental Hospital. Bone maturity is measured by the opening degree of growth plate and bone density in ultrasonic image of calcaneus bone This study were designed to investigate the relationship of the development of children and the calcaneus bone maturity. Result: The opening degree of growth plate was no change in aged 5-10 years for male and 5-9 years for female but decreased significantly from aged 11 years for male and 10 years for female. the bone density was no change in aged 5-12 years for male and 5-11 years for female but increased significantly from aged 13 years for male and 12 years for female. it was confirmed that bone maturity in female is more rapid than in male. The opening degree of growth plate of claclneus bone was correlated with age, height, weight. The bone density was correlated with age, height, weight, BMI in this suudy(P<0.001) Conclusion: The opening degree of growth plate and bone density of calcaneus bone are sufficient diagnostic worth as an index to predict adolescent growth.

  • PDF

Underwater Image Preprocessing and Compression for Efficient Underwater Searches and Ultrasonic Communications

  • Kim, Dong-Hoon;Song, Jun-Yeob
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.1
    • /
    • pp.38-45
    • /
    • 2007
  • We propose a preprocessing method for removing floating particles from underwater images based on an analysis of the image features. We compared baseline JPEG and wavelet codec methods to determine the method best suited for underwater images. The proposed preprocessing method enhanced the compression ratio and resolution, and provided an efficient means of compressing the images. The wavelet codec method yielded better compression ratios and image resolutions. The results suggest that the wavelet codec method linked with the proposed preprocess method provides an efficient codec processor and transmission system for underwater images that are used for searches and transmitted via ultrasonic communications.

Edge Detection of Sonogram Using Sobel Operator (Sobel 연산자를 이용한 초음파 영상의 경계선 검출)

  • Choi, Gui-Rack;Lee, Jun-Hang
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.17-21
    • /
    • 2008
  • Image quality is improved if the high frequency domains of boundary surface are made distinct. We suggested a method of correcting indistinct defects in ultrasonic images resulting from dynamic imaging. According to the results of the experiment, boundaries in input ultrasonic images became distinct. However, we need to solve the problem that information on pixels of low signal intensity adjacent to boundaries is lost because high-frequency components in the boundaries are strong.

  • PDF