• Title/Summary/Keyword: Ultrasonic frequency

Search Result 907, Processing Time 0.028 seconds

Mathematical modeling of concrete beams containing GO nanoparticles for vibration analysis and measuring their compressive strength using an experimental method

  • Kasiri, Reza;Massah, Saeed Reza
    • Advances in nano research
    • /
    • v.12 no.1
    • /
    • pp.73-79
    • /
    • 2022
  • Due to the extensive use of concrete structures in various applications, the improvement of their strength and quality has become of great importance. A new way of achieving this purpose is to add different types of nanoparticles to concrete admixtures. In this work, a mathematical model has been employed to analyze the vibration of concrete beams reinforced by graphene oxide (GO) nanoparticles. To verify the accuracy of the presented model, an experimental study has been conducted to compare the compressive strengths of these beams. Since GO nanoparticles are not readily dissolved in water, before producing the concrete samples, the GO nanoparticles are dispersed in the mixture by using a shaker, magnetic striker, ultrasonic devices, and finally, by means of a mechanical mixer. The sinusoidal shear deformation beam theory (SSDBT) is employed to model the concrete beams. The Mori-Tanaka model is used to determine the effective properties of the structure, including the agglomeration influences. The motion equations are calculated by applying the energy method and Hamilton's principle. The vibration frequencies of the concrete beam samples are obtained by an analytical method. Three samples containing 0.02% GO nanoparticles are made and their compressive strengths are measured and compared. There is a good agreement between our results and those of the mathematical model and other papers, with a maximum difference of 1.29% between them. The aim of this work is to investigate the effects of nanoparticle volume fraction and agglomeration and the influences of beam length and thickness on the vibration frequency of concrete structures. The results show that by adding the GO nanoparticles, the vibration frequency of the beams is increased.

Effect of Ultrasound Therapy at the ST11 on Sympathetic Nervous System Change: A Prospective Randomized Controlled Study (기사혈(氣舍穴, ST11)에 적용한 혈위 초음파요법이 교감신경계에 미치는 영향: 전향적 무작위 대조군 연구)

  • Shinwoo Kang;Dongho Keum
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.4
    • /
    • pp.167-184
    • /
    • 2023
  • Objectives This study was designed to assess the effectiveness of ultrasound therapy at the ST11 for regulation of sympathetic hyperactivity. Methods Forty healthy adult subjects were assigned to experimental group and control group. After taking mental stress, ultrasound therapy was applied at the ST11 in experimental group and sham-ultrasound therapy was applied in control group. The evaluation of sympathetic activity was measured by blood pressure, pulse rate, and heart rate variability at 3 times (Time 1: before the stress stimulation, Time 2: after the stress stimulation, Time 3: after the intervention). The primary end point was consisted of normalized (norm) low frequency (LF)/high frequency (HF) ratio, LF (norm), HF (norm). The secondary end point was consisted of systolic blood pressure, diastolic blood pressure, pulse rate, mean heart rate, standard deviation of NN intervals, root mean square of the successive differences, total power (log). Results After the stress stimulation, all subjects showed sympathetic hyperactivity. After the intervention, the experimental group showed lower sympathetic activity than the control group. Comparing the Time 3 and Time 1, the experimental group showed no significantly differences in sympathetic activity while the control group showed higher sympathetic activity in Time 3 than Time 1. Comparing the Time 3 and Time 2, the experimental group showed lower sympathetic activity in Time 3 than Time 2 while the control group showed higher sympathetic activity in Time 3 than Time 2. Conclusions We suggest that the ultrasound therapy at ST11 can decrease sympathetic activity in sympathetic hyperactivity condition.

Estimation of Concrete Strength Based on Artificial Intelligence Techniques (인공지능 기법에 의한 콘크리트 강도 추정)

  • 김세동;신동환;이영석;노승용;김성환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.7
    • /
    • pp.101-111
    • /
    • 1999
  • This paper presents concrete pattern recognition method to identify the strength of concrete by evidence accumulation with multiple parameters based on artificial intelligence techniques. At first, variance(VAR), zero-crossing(ZCR), mean frequency(MEANF), and autoregressive model coefficient(ARC) and linear cepstrum coefficient(LCC) are extracted as feature parameters from ultrasonic signal of concrete. Pattern recognition is carried out through the evidence accumulation procedure using distance measured with reference parameters. A fuzzy mapping function is designed to transform the distances for the application of the evidence accumulation method. Results(92% successful pattern recognition rate) are presented to support the feasibility of the suggested approach for concrete pattern recognition.

  • PDF

The Effects of Wound Healing of Pulsed Ultrasound in Diabetic Induced Rats (맥동성초음파가 당뇨유발백서의 창상치유에 미치는 효과)

  • Min, Soon-Gyu;Kim, Kye-Yoep;Oh, Myung-Hwa
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.1 no.1
    • /
    • pp.87-100
    • /
    • 2003
  • The present studies have been designed to evaluate the effect of acute wound healing that frequency and intensity of pulsed ultrasound application in diabetic rat. Mild diabetes mellitus was induced in rat with 45 mg/kg streptozotocin. The results were analyzed and summarized as follows: 1. The rate of wound length on ultrasonic capacity in $1.0\;W/cm^2$ $SATA_i$ group was more significantly decreased than $0.5\;W/cm^2$ $SATA_i$ group. 2. In the histological change, the $1.0\;W/cm^2$ $SATA_i$ application group was more effective than $0.5\;W/cm^2$ $SATA_i$ group, decrease of inflammatory cell was significantly in several groups. From the conclusions above, in this study application of 3 MHz pulsed ultrasound in acute wound healing, $1.0\;W/cm^2$ $SATA_i$ capacity can be an effective way of promotion wound healing than $0.5\;W/cm^2$ $SATA_i$ capacity in diabetic rat.

  • PDF

Evaluation of Corrosion Degradation Characteristics of Turbine Blade Material Using Backward Radiated Ultrasound (후방복사된 초음파를 이용한 터빈 블레이드 재료의 부식 열화특성 평가)

  • Song, Sung-Jin;Kim, Young-H.;Bae, Dong-Ho;Jung, Min-Ho;Kwon, Sung-Duk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2322-2327
    • /
    • 2002
  • The corrosion degradation characteristics of the 12Cr alloy steel, which is widely used in fossil power plants as a turbine blade material, are evaluated nondestructively by use of the backward radiated Rayleigh surface wave. In order to evaluate corrosion degradation characteristics, we constructed automated system for the backward radiation, and the frequency dependency of the Rayleigh surface wave is investigated indirectly by measuring the angular dependency of the backward radiation of the incident ultrasonic wave in the specimens. The velocity of the surface wave decrease as the increase of the aging time in the backward radiation profile, which seems to result from the increase of the effective degrading layer thickness. And, amplitude of the surface wave increase as the aging time, which seems to result from the increase of the intergranular corrosion. The result observed in this study demonstrates high potential of the backward radiated ultrasound as a tool for the nondestructive evaluation of the corrosion degradation characteristics of the aged materials.

Development of Walking Guide Robot for the Blind (시각장애인을 위한 보행안내로봇 개발)

  • Yu K.H.;Yoon M.J.;Kwon T.K.;Kim N.G.;Kang J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.888-891
    • /
    • 2005
  • In this paper, the prototype of a walking guide robot with tactile display is introduced, and the psychophysical experiment of the tactile recognition for a tactile display is carried out and analyzed. The objective of this research is the development of a walking guide robot for the blind to walk safely. A walking guide robot consists of a guide vehicle and a tactile display device. A guide vehicle, located in the front of the walking blind, detects the obstacle using ultrasonic sensors and offers the information of position and walking direction acquired from GPS module to the walking blind by voice. The tactile display device, located in the handle which is connected with the guide vehicle by cane, offers the processed obstacle information such as position, size, moving, shape of obstacle and safe path, etc. The psychophysical experiments for the threshold of perception and recognition ability of tactile stimulation are carried out by the estimation of the subject group. As a result the appropriate tactile stimulus intensity and frequency to recognize tactile stimulation effectively are discussed and derived.

  • PDF

The Design & Manufacture of Multi-coil Eddy Current Sensor and Characteristic Analysis (다중코일 와전류 센서 설계제작 및 특성분석)

  • Ahn, Y.S.;Gil, D.S.;Park, S.G.
    • Journal of Power System Engineering
    • /
    • v.15 no.3
    • /
    • pp.65-69
    • /
    • 2011
  • This paper introduces the multi-coil eddy current sensor and its characteristic in magnetic material gas turbine rotor. In the past, magnetic particle inspection method was used for qualitative defect evaluation in magnetic material gas turbine rotor. And the ultrasonic inspection method was used for quantitative defect evaluation. Nowadays, eddy current method is used in magnetic gas turbine rotor inspection due to advanced sensor design technology. We developed multi-coil eddy current sensor for the rotor dovetail inspection. At first, rotor stress is analyzed for the determination of sensor position and number. The sensor coils are designed to cover the stress concentration area of rotor dovetail. We select optimum frequency according to material standard penetration data and experiment results. The rotor mock-up and artificial defects were made for the signal detection and resolution analysis of multi-coil eddy current sensor. The results show that signal detection and resolution capabilities are enhanced in comparison to the commercialized sensor enough for the gas turbine rotor inspection. So, this developed multi-coil eddy current sensor substituted for commercialized one and it applied in real gas turbine rotor inspection.

The Electric Field Dependence of the Resonance Characteristics and Piezoelectric Constant of the PZT-PMNS Ceramics (PZT-PMNS 세라믹의 공진특성 및 압전 정수의 전계의존성)

  • Oh, Jin-Heon;Lim, Kee-Joe;Kang, Seong-Hwa;Kim, Hyeon-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.179-180
    • /
    • 2008
  • In this paper, the variable tendency piezoelectric constant and resonance characteristics piezoelectric ceramics due to the electric field is studied. The practical application of piezoelectric ceramics is not only applied in field of small signal. For example, in case of an ultrasonic motor, $120{\sim}130Vrms$ of driving voltage is needed and that of an piezoelectric pump, $200{\sim}220Vrms$ of voltage is required. Therefore, to examine the characteristics of piezoelectric ceramics in large signal contributes to reducing the susceptibility to the multifarious application and securing the ease of the production of control circuit. These contributions may be connected to the expansion of industrial application. We fabricated disk-type piezoelectric ceramic samples by using conventional method and measured the resonance characteristics of these samples under from low to high voltage driving conditions. According to increasing the value of the input voltage, we measured the resonance frequency of the piezoelectric ceramic, and inquired into the cause of these phenomena.

  • PDF

Characteristics of Pulse Width Modulation(PWM) Excitation of Ultrasonic Elliptical Vibration Cutting Device (초음파 진동절삭기의 펄스폭변조 가진 특성)

  • Loh, Byoung Gook;Kim, Gi Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.59-65
    • /
    • 2014
  • To obtain an elliptical trajectory at the cutting edge during elliptical vibration cutting, sinusoidal voltage excitations of two piezoelectric actuators have commonly been used. In this study, PWM excitation, which is relatively simple to generate, was employed and its characteristics were investigated. In experimental and analytical analyses, we found that for PWM excitation, the integer-multiple frequencies of the excitation voltage distorted the shape of the elliptical trajectory, whereas at a duty ratio(DR) of 50%, the distortion of the elliptical trajectory was minimized due to disappearance of the first overtone. When the magnitude of the maximum excitation voltage was maintained at the same level for both PWM and sinusoidal excitation, PWM (DR=50%) excitation produced a greater vibration amplitude than sinusoidal excitation but resulted in more rapid saturation of a high-frequency power amplifier.

The Evaluation Technique of Surface Region using Backward-Radiated Ultrasound (후방 복사된 초음파를 이용한 표면 지역의 평가 기술)

  • Kwon, S.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.4
    • /
    • pp.241-250
    • /
    • 1997
  • The velocity dispersion of surface acoustical wave(SAW) of Si layer/mesh Au/Si substrate was measured by the frequency analysis technique of backward radiation at liquid/solid interface. The difference of backward radiation patterns depending on used transducers (2, 5, 10MHz) confirmed that the backward radiation phenomenon was caused by the energy radiation from SAW generated in surface region. An ultrasonic goniometer was constructed to measure continuously the angular dependence of backscattered intensity. The angular dependences of backward radiation(5MHz) were measured for Ni layer/Al substrate specimens that were bonded by epoxy involving different content of Cu powder. It was known that the width and pattern of backward radiation had informations such as the velocity dispersion, bonding quality and structure of surface region.

  • PDF