• Title/Summary/Keyword: Ultrasonic focusing

Search Result 88, Processing Time 0.031 seconds

Characteristics of a 2-2 Composite Transmitting/P(VDF-TrFE) Receiving Wideband Focusing Ultrasonic Transducer (2-2 Composite 송신/P(VDF-TrFE) 수신 광대역 집속 초음파 트랜스듀서의 특성)

  • Ha Kang-Lyeol;Kim Dong-Hyun;Kim Moo-Joon;Kim Jung-Ho
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.357-358
    • /
    • 2004
  • 생체 피부하 약 5mm이내 영역에 대한 고분해능의 B-모드 영상을 얻는 데 사용할 수 있는 축 방향 분해능 $30{\mu}m$ 이하인 VHF 대역 초음파 트랜스듀서로서 용융석영을 음향버퍼의 하여 그 양단에 송신용 2-2 composite와 수신용 P(VDF-TrFE)를 설치한 송수신 분리형의 집속 트랜스듀서의 구조를 새로이 제안하고, 그 전기적 음향적 특성을 시뮬레이션 하였다. 그 결과, 2-2 composite 투께 $18{\mu}m$와 P(VDF-TrFE) 두께 $12{\mu}m$의 트랜스듀서는 중심주파수 43.0MHz, 비대역 $74\%$이며, 삽입손실이 25dB인 비교적 우수한 트랜스듀서가 될 수 있음을 알았다.

  • PDF

Defect Detection Using Focused Lamb Waves Generated by Laser (집속형 레이저 유도초음파에 의한 결함검출)

  • Kim, Hong-Joon;Jung, Ji-Hong;Ha, Job;Jhang, Kyung-Young
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.774-779
    • /
    • 2003
  • Arc-shaped line array slits have been used for the laser generation of focused Lamb waves. The spatially expanded Nd:YAG pulse laser was illuminated through the arc-shaped line array slit on the surface of a sample plate to generate the Lamb waves of the same pattern as the slit. Then the generated Lamb waves were focused at the point of which distance from the slit position is dependent on the curvature of slit arc. The proposed method showed better spatial resolution than the conventional linear array slit in the detection of laser machined linear defect and drill machined circular defect on aluminum plates of 1mm thickness.

  • PDF

A Study on Sidelobe Reduction Using Kaiser Window in Ultrasonic Imaging System (초음파 영상시스템에서 카이저 윈도우를 이용한 사이드 로브 감축에 관한 연구)

  • Na, Byeong-Yoon;Ahn, Young-Bok;Jeong, Mok-Kun
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.189-200
    • /
    • 1996
  • In this paper, we compared the performance of the Kaiser window with those of others as a weight function of well known anodization technique for regression of side lobe in a field pattern resulted from focusing of transducer array. The Kaiser window is an window providing many types of curve with several variables. In order to compare performance of the Kaiser window as the weight function, anodization results of the previously used Hamming window function and the Matched Gaussian function are compared Result of computer simulation, the pertormance of Kaiser window with $\delta$=0.0025 in side lobe regression was better than that of Hamming window or Matched Gausian function.

  • PDF

High Frequency Ultrasound and Its Applications to Animal and Human Imaging Focusing on Vessel and Blood (고주파 초음파의 그 응용: 혈관과 혈액을 중심으로한 동물과 인체 영상)

  • Bok, Tae-Hoon;Paeng, Dong-Guk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.2E
    • /
    • pp.73-85
    • /
    • 2010
  • In the diagnostic ultrasound (US) transducer technology, the high frequency US(HFUS) transducer over 20 MHz is one of the current issues to be pursued for better resolution with the expense of penetration. HFUS single element transducers and the mechanical scanning systems for imaging are reviewed, and HFUS array transducers are also briefly summarized. HFUS applications such as the human applications in ophthalmology and dermatology and small animal applications for research purposes are reviewed with vascular and blood imaging in this paper.

Characteristics of Point-Focus Type Ultrasonic Transducer using PVDF Element (고분자(高分子) PVDF 진동자(振動子)를 이용(利用)한 점집동초음파탐촉자(点集東超音波探觸子)의 특성)

  • Han, E.K.;Hwang, S.T.;Lee, B.S.;Park, J.S.;Ogura, Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.12 no.2
    • /
    • pp.7-13
    • /
    • 1992
  • In this study, we examine the characteristics of beam and the effect of these characteristics on the flaw detection by using different type of two transducers, which are PZT and PVDF film transducer. Consequently, the detection of infinitesimal flaw is more possible than PZT, since it has beam width at focus of $60%{\sim}65%$ in contrast with PZT's. Moreover we can know PVDF transducer has superiority in detecting ability for sub-surface flaw detection in view of its acoustic impedance is near to water's and its focusing range is narrower than PZT's as $65{\sim}85%$ because it has spherical surface.

  • PDF

A Study on the Change of Clinical Self-Confidence according to the Number of Clinical Dental Hygiene Practices of Students in the Department of Dental Hygiene - Focusing on scaling practices -

  • Choi, Yong-Keum;Kim, Mi-Sun;Jeong, Su-Ra;Kim, Eun-Jeong
    • Journal of Korean Dental Hygiene Science
    • /
    • v.3 no.2
    • /
    • pp.39-49
    • /
    • 2020
  • The purpose of this study was to provide the basic data needed to plan the effective teaching design of scaling education and to measure the changes in students' confidence in performing scaling according to the number of scaling practices. Scaling education is presented as a core basic hygiene competency of dental hygienists and evaluated as the practical competency of dental hygienists. This study selected 48 third-year students from the department of dental hygiene at S University in Asan, and analyzed data from completed participant surveys. The degree of "confidence in facing the subject in clinical practice," "confidence in applying hand instrument to the subject," and "confidence in applying ultrasonic instruments to the subject" was assessed on a five-point Likert scale. The difference in confidence was analyzed during five practice sessions. Each response was compared using frequency analysis, chi-square test, and repeated measurement ANOVA. Students who complained of a lack of confidence in the 14.6%, 25.0%, and 12.5%, respectively, in face-to-face practice, hand instruments, and ultrasonic instrument application responses. The more the practice was repeated, the more confident students were in all three categories, and the more statistically significant (p<0.001). As the number of scaling practice sessions increased, students' confidence in performing scaling also improved. In particular, the level of self-confidence was higher after the third practice session when compared to the first session. Therefore, it is necessary to design effective courses for teaching scaling practices so that at least three repetitive practice periods can be provided in clinical dental hygiene practices.

Pipeline defect detection with depth identification using PZT array and time-reversal method

  • Yang Xu;Mingzhang Luo;Guofeng Du
    • Smart Structures and Systems
    • /
    • v.32 no.4
    • /
    • pp.253-266
    • /
    • 2023
  • The time-reversal method is employed to improve the ability of pipeline defect detection, and a new approach of identifying the pipeline defect depth is proposed in this research. When the L(0,2) mode ultrasonic guided wave excited through a lead zirconate titinate (PZT) transduce array propagates along the pipeline with a defect, it will interact with the defect and be partially converted to flexural F(n, m) modes and longitudinal L(0,1) mode. Using a receiving PZT array attached axisymmetrically around the pipeline, the L(0,2) reflection signal as well as the mode conversion signals at the defect are obtained. An appropriate rectangle window is used to intercept the L(0,2) reflection signal and the mode conversion signals from the obtained direct detection signals. The intercepted signals are time reversed and re-excited in the pipeline again, result in the guided wave energy focusing on the pipeline defect, the L(0,2) reflection and the L(0,1) mode conversion signals being enhanced to a higher level, especially for the small defect in the early crack stage. Besides the L(0,2) reflection signal, the L(0,1) mode conversion signal also contains useful pipeline defect information. It is possible to identify the pipeline defect depth by monitoring the variation trend of L(0,2) and L(0,1) reflection coefficients. The finite element method (FEM) simulation and experiment results are given in the paper, the enhancement of pipeline defect reflection signals by time-reversal method is obvious, and the way to identify pipeline defect depth is demonstrated to be effective.

Image Enhancement for Sub-Harmonic Phased Array by Removing Surface Wave Interference with Spatial Frequency Filter

  • Park, Choon-Su;Kim, Jun-Woo;Cho, Seung Hyun;Seo, Dae-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.211-219
    • /
    • 2014
  • Closed cracks are difficult to detect using conventional ultrasonic testing because most incident ultrasound passes completely through these cracks. Nonlinear ultrasound inspection using sub-harmonic frequencies a promising method for detecting closed cracks. To implement this method, a sub-harmonic phased array (PA) is proposed to visualize the length of closed cracks in solids. A sub-harmonic PA generally consists of a single transmitter and an array receiver, which detects sub-harmonic waves generated from closed cracks. The PA images are obtained using the total focusing method (TFM), which (with a transmitter and receiving array) employs a full matrix in the observation region to achieve fine image resolution. In particular, the receiving signals are measured using a laser Doppler vibrometer (LDV) to collect PA images for both fundamental and sub-harmonic frequencies. Oblique incidence, which is used to boost sub-harmonic generation, inevitably produces various surface waves that contaminate the signals measured in the receiving transducer. Surface wave interference often degrades PA images severely, and it becomes difficult to read the closed crack's position from the images. Various methods to prevent or eliminate this interference are possible. In particular, enhancing images with signal processing could be a highly cost-effective method. Because periodic patterns distributed in a PA image are the most frequent interference induced by surface waves, spatial frequency filtering is applicable for removing these waves. Experiments clearly demonstrate that the spatial frequency filter improves PA images.

Enhanced Auto-focus algorithm detecting target object with multi-window and fuzzy reasoning for the mobile phone (목적물 인식 및 자동 선택이 가능한 모바일 폰 용 자동초점 알고리즘)

  • Lee, Sang-Yong;Oh, Seung-Hoon;Kim, Soo-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.3 s.357
    • /
    • pp.12-19
    • /
    • 2007
  • This paper proposes the enhanced auto-focus algorithm detecting several objects and selecting the target object. Proposed algorithm first detects some objects distributed in the image using focus measure operator and multi-window and then selects the target object through fuzzy reasoning with three fuzzy membership functions. Implementation can be simple because it only needs image sensor instead of infrared or ultrasonic equipment. Experimental result shows that the proposed algorithm can improve the quality of image by focusing to the target object.

Analysis of Low-Profile Piezoelectric Butterfly Linear Motor using 3D Laser Vibrometer

  • Lee, Won-Hee;Kang, Chong-Yun;Paik, Dong-Soo;Ju, Byeong-Kwon;Yoon, Seok-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.325-325
    • /
    • 2010
  • Piezoelectric linear motors have been widely studied for auto focusing devices of digital cameras and cellular phones due to their simple structure. In this paper, we confirmed that novel piezoelectric butterfly linear motor was fabricated and its dynamic properties were analyzed. The piezoelectric transducer (having size $9{\times}8{\times}1\;mm^3$) is composed of an elastic plate, which includes a tip for energy transfer and two fixing protrusions for fixture, and two piezoelectric ceramics. The butterfly linear motor has been designed and optimized using A TILA simulation program. The superposed motion is an elliptical vibration on the tip. The actual movement of the manufactured actuator was confirmed by a 3D laser dopier vibrometer and compared with the simulation results. The results of numerical study and experimental investigation will be used for the future optimization of the actuator and the realization of the advanced ultrasonic motor.

  • PDF