• Title/Summary/Keyword: Ultrasonic focusing

Search Result 88, Processing Time 0.025 seconds

Design of Linear Ultrasonic Motor for Small tong Actuation (렌즈 구동을 위한 선형 초음파 전동기 설계)

  • Kwon Taeseong;Lee Seung-Yop;Kim Sookyung
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.190-194
    • /
    • 2005
  • There is a great demand of micro-actuators for mobile information devices such as SFF optical drives and mobile camera phones. However, conventional magnetic coils of electromagnetic motors are a major obstacle for miniaturization because of their complicated structures and large power consumption. In this paper, a linear ultrasonic motor to actuate focusing lens of mobile devices is proposed. The new actuator uses a ring type bimorph piezoelectric material, and $d_{31}$ mode is adopted for applying linear motion. The interaction between inertia force and friction force makes linear motion by high-frequency saw signal input. The saw signal gives steady forces on the one direction by asymmetric inclination property of the signal itself on time domain. A commercial FEM (ANSYS) was used in this investigation for simulating structural analysis, identification of dynamic property, such as resultant displacement and coupled analysis with piezoelectric material. To evaluate the performance of the new design, a prototype was manufactured and experiments were carried out. Experimental results show the actuator motion of 1.52 mm/s at 10 kHz input signal in 5 V.

  • PDF

Design of a Linear Ultrasonic Actuator for Small Lens Actuation (초소형 렌즈 구동을 위한 선형 초음파 구동기 설계)

  • Kwon, Tae-Seong;Choi, Yo-Han;Lee, Seung-Yop
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.4
    • /
    • pp.251-256
    • /
    • 2006
  • There is a great demand of micro-actuators for mobile information devices such as SFF optical drives and mobile phone cameras. However, the magnetic coils used in conventional electromagnetic motors are a major obstacle for the miniaturization because of their complicated structures and large power consumption. In this paper, a linear ultrasonic motor to actuate focusing lens of mobile devices is proposed. The new actuator uses a ring type bimorph piezoelectric material, and $d_{31}$ mode is adopted for applying linear motion. The interaction between inertia force and friction force makes linear motion by high-frequency saw signal input. The saw signal gives steady forces on the one direction by asymmetric inclination property of the signal itself on time domain. A commercial FEM(ANSYS) was used in this investigation for simulating structural analysis, identification of dynamic property, such as resultant displacement and coupled analysis with piezoelectric material. To evaluate the performance of the new design, a prototype was manufactured and experiments were carried out. Experimental results show the actuator motion of 5.4 mm/s at 10V saw signal of 41 kHz.

  • PDF

Analysis of Broadband Ultrasonic Field Response and its Application to the Design of Focused Annular Array System (광대역 초음파 장 응답의 해석과 집속된 Annular Array 영상 시스템 설계에의 응용)

  • Rho, Gyoung-Tae;Song, Tae-Kyung;Park, Song-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1252-1255
    • /
    • 1987
  • In this paper an approach for the analysis of the transient field response of radially symmetric transducer due to a wideband ultrasonic pulse is presented, which is based on a development of Green's function and applies the linear system theory to obtain an analytic expression for the impulse response of an annulus with a planar or spherical geometry. For the focused annular array, the impulse responses of the indivisual annuli are convolved with the delayed excitation pulse, and then summed to obtain the resultant response of the array. This process is very effective in the study of the various focusing abilities of the annular array. For illustration, the field distribution of a five element annular array is treated in detail for several focusing system.

  • PDF

Ultrasonic Targeting of NK Cell in Vessel Bifurcation for Immunotherapy: Simulation and Experimental Validation

  • Saqib Sharif;Hyeong-Woo Song;Daewon Jung;Hiep Xuan Cao;Jong-Oh Park;Byungjeon Kang;Eunpyo Choi
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.418-424
    • /
    • 2023
  • Natural killer (NK) cells play a crucial role in combating infections and tumors. However, their therapeutic application in solid tumors is hindered by challenges, such as limited lifespan, tumor penetration, and delivery precision. Our research introduces a novel ultrasonic actuation technique to navigate NK cells more effectively in the vascular system, particularly at vessel bifurcations where targeted delivery is most problematic. We use a hemispherical ultrasonic transducer array that generates phase-modulated traveling waves, focusing on an ultrasound beam to steer NK cells using blood-flow dynamics and a focused acoustic field. This method enables the precise obstruction of non-target vessels and efficiently directs NK cells toward the tumor site. The simulation results offer insights into the behavior of NK cells under various conditions of cell size, radiation pressure, and fluid velocity, which inform the optimization of their trajectories and increase targeting efficiency. The experimental results demonstrate the feasibility of this ultrasonic approach for enhancing NK cell targeting, suggesting a potential leap forward in solid tumor immunotherapy. This study represents a significant step in NK cell therapeutic strategies, offering a viable solution to the existing limitations and promising enhancement of the efficacy of cancer treatments.

A Study on Techniques for Focusing Circumferential Array Guided Waves for Long Range Inspection of Pipes (배관 원거리 진단을 위한 원주방향 배열 유도초음파 집속기술 개발)

  • Kang, To;Kim, Hak-Joon;Song, Sung-Jin;Cho, Young-Do;Lee, Dong-Hoon;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.114-121
    • /
    • 2009
  • Ultrasonic guided waves have been widely utilized for long range inspection of structures. Especially, development of array guided waves techniques and its application for long range gas pipe lines(length of from hundreds meters to few km) were getting increased. In this study, focusing algorithm for array guided waves was developed in order to improve long range inspectability and accuracy of the array guided waves techniques for long range inspection of gas pipes, and performance of the developed techniques was verified by experiments using the developed array guided wave system. As a result, S/N ratio of array guided wave signals obtained with the focusing algorithm was increased higher than that of signals without focusing algorithm.

A Reduction of Grating Lobe By Using the Multi-element Receive Synthetic Focusing In Ultrasonic Image (초음파 영상에서 Multi-element Receive Synthetic Focusing을 이용한 그레이팅 로브 감축)

  • Lee, J.S.;Ahn, Y.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.559-562
    • /
    • 1997
  • In this paper, we propose the method that reduce the grating lobe in the ultrasound synthetic focusing images. synthetic focusing images have more larger and closer grating lobe than conventional phased array images and more lower signal to noise ratio. so, we represent the method that reduce the grating lobe by using multi element receive focusing. experimental results are showed that the proposed multi element receiving method reduce the grating lobe and increase the signal to noise ratio.

  • PDF

How to make spatially focused sound shape: wavenumber spectrum matching (공간 상에 원하는 음장형상을 만드는 방법)

  • Park, Jin-Young;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1014-1017
    • /
    • 2007
  • Sound focusing technologies has been studied for various purposes from early 1990s. As a result, these technologies make us possible to apply in many uses. For example, we can treat tumors using focused ultrasonic waves without surgical knife and communicate in the ocean using time reversal array. Also applications for personal audio system become issues. Recently, as technologies are developing, in some applications, needs for regional focusing become increasing because previously suggested focusing methods, such as phase conjugation, time reversal and inverse filtering, were all about a point focusing. Therefore, studies on regional focusing method are essentially needed. Regional focusing method was firstly mentioned by Choi and Kim in 2002: acoustic contrast control. However, in regional focusing, physical interpretations between control variables and results are still not easy because of its complexity. In this regard, we tried to understand the relations between control variables and results in wavenumber domain and suggested a solution method for regional focusing: wavenumber spectrum matching. We also showed how to make spatially focused sound shape using the suggested method from the simplest case: line focusing.

  • PDF

A $PbTiO_{3}$ Transmitting/P(VDF-TrFE) Receiving Wideband Ultrasonic Transducer in VHF Band (VHF 대역에 있어서 $PbTiO_{3}$송신/P(VDF-TrFE) 수신 광대역 초음파변환자)

  • Ha, Kang-Lyeol;Kim, Moo-Joon;Kim, Jung-Ho;Kim, Jung-Soon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.4E
    • /
    • pp.120-124
    • /
    • 2004
  • A new type of high frequency wideband ultrasonic transducer with a separation between a transmitter and a receiver was proposed and its characteristics were simulated using a PSpice model. The piezoelectric ceramic $PbTiO_{3}$ as a transmitter and the piezoelectric copolymer P(VDF- TrFE) as a receiver were used for high sensitivity and wide bandwidth, respectively. The characteristics of the focusing transducer with center frequency of approximately 35MHz fabricated in this study showed very wide bandwidth, which could give an axial spatial resolution better than $30{\mu}m$ in B-mode image for biological tissues.

Impact Localization for a Composite Plate Using the Spatial Focusing Properties of Advanced Signal Processing Techniques

  • Jeong, Hyunjo;Cho, Sungjong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.6
    • /
    • pp.703-710
    • /
    • 2012
  • A structural health monitoring technique for locating impact position in a composite plate is presented in this paper. The method employs a single sensor and spatial focusing properties of time reversal(TR) and inverse filtering(IF). We first examine the spatial focusing efficiency of both approaches at the impact position and its surroundings through impact experiments. The imaging results of impact localization show that the impact location can be accurately estimated in any position of the plate. Compared to existing techniques for locating impact or acoustic emission source, the proposed method has the benefits of using a single sensor and not requiring knowledge of anisotropic material properties and geometry of structures. Furthermore, it does not depend on a particular mode of dispersive Lamb waves that is frequently used in other ultrasonic testing of plate-like structures.

Ultrasonic Osteotome Assisted Posterior Endoscopic Cervical Foraminotomy in the Treatment of Cervical Spondylotic Radiculopathy Due to Osseous Foraminal Stenosis

  • Ye Jiang;Chen Li;Lutao Yuan;Cong Luo;Yuhang Mao;Yong Yu
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.4
    • /
    • pp.426-437
    • /
    • 2023
  • Objective : To investigate the efficacy and safety of the posterior endoscopic cervical foraminotomy (PECF) using ultrasonic osteotome for the treatment of cervical osseous foraminal stenosis, focusing on introduction of the advantages of ultrasonic osteotome in partial pediculectomy and ventral osteophyte resection in PECF. Methods : Nineteen patients with cervical osseous foraminal stenosis who underwent PECF using ultrasonic osteotome in our institution between April 2018 and April 2021 were enrolled in this study. All the patients were followed up more than 12 months. The patients' medical data, as well as pre- and postoperative radiologic findings were thoroughly investigated. The visual analogue score (VAS), Japanese Orthopaedic Association (JOA) score, cervical dysfunction index (Neck disability index, NDI), and modified MacNab criteria were used to assess the surgical efficacy. Results : All the patients were successfully treated with PECF using ultrasonic osteotome. The pre- and postoperative VAS, NDI, and JOA scores were significantly improved (p<0.05). According to the modified MacNab criteria, 17 patients were assessed as "excellent", two patients were assessed as "good" at the last follow-up. There was no dura tear, nerve root damage, incision infection, neck deformity, or other complications. Conclusion : Adequate nerve root decompression can be accomplished successfully with the help of ultrasonic osteotome in PECF, which has the advantage of reducing the probability of damage to the nerve root and dura mater, in addition to the original merits of endoscopic surgery.