• 제목/요약/키워드: Ultrasonic Vibrator

검색결과 124건 처리시간 0.027초

초음파 절삭기 핸드피스부 제작 및 변위 특성 시뮬레이션 (Fabrication and Simulation of Displacement Properties of Ultrasonic Generator Handpiece)

  • 김승원;류주현;이지영
    • 한국전기전자재료학회논문지
    • /
    • 제31권3호
    • /
    • pp.152-155
    • /
    • 2018
  • Ultrasonic wave technologies have been widely used in ultrasonic washing machines, ultrasonic surgery, ultrasonic welding machines, ultrasonic sensors, and medical instruments. Ultrasonic surgery can be realized through the cavitation effect of ultrasonic waves. In this study, piezoelectric ceramics were manufactured to achieve the optimum design of a piezoelectric vibrator in a handheld generator for ultrasonic surgery. The best specimen showed the excellent piezoelectric properties of kp=0.624, Qm=1,531, and $d_{33}=356pC/N$. Numerical modeling based on the finite element method was performed to find the resonance frequency, the anti-resonance frequency, and the displacement properties of the handheld ultrasonic generator. Maximum displacement was observed in the six-step piezoelectric vibrator at $6.36{\mu}m$.

치과용 골 수술기의 초음파 진동자 설계 및 평가 (Evaluation and Design of Ultrasonic Vibrator for Dental Surgery)

  • 박기문;김정현;고태조
    • 한국기계가공학회지
    • /
    • 제15권3호
    • /
    • pp.102-108
    • /
    • 2016
  • A dental ultrasonic surgical instrument, commercially known as a scaler, is a high-value-added advanced technology that is used for tartar removal, implant operations, and gum and jaw bone surgery. In this study, the piezoelectric phenomenon for making linear motion associated with input electrical signals was studied, and the behavior of the ultrasonic vibrator was investigated by using the commercially available finite element program ANSYS(R) for the purpose of designing dental surgery tools. Modal analysis was carried out, and the optimal frequency range was calculated from the analyzed results. The ultrasonic vibrator was then redesigned based on the calculated optimal frequency range. The performance of the system was tested, and consequently, the proposed methodology was proven useful in vibrator design.

입자 영상 유속계를 이용한 초음파 수직진동에 의해 유도된 공진상태에서의 음향유동에 관한 연구 (Study of Acoustic Streaming at Resonance by Longitudinal Ultrasonic Vibration Using Particle Imaging Velocimetry)

  • 노병국;이동렬
    • 한국음향학회지
    • /
    • 제23권5호
    • /
    • pp.340-352
    • /
    • 2004
  • 28.5 ㎑의 초음파의 미세 수직진동에 의해서 유도된 음향유동 (acoustic streaming)을 레이저를 이용한 입자 영상. 유속계에 의하여 고정 유리 평판과 초음파 진동자의 사이에서의 공기 유동을 가시화 하였다. 음향유동에 의한 공기의 유동 속도의 증가를 측정하기 위해 고정 유리 평판과 초음파 진동자의 사이에서의 속도변화를 실시간으로 측정하였다. 진동자와 고정 평판의 사이의 gap에 따른 음향유동의 세기의 변화를 정량적인 공기의 유동 속도의 변화에 의해 관찰되었고 고정판과 초음파 진동자 사이의 gap에서 공진 상태를 야기시키는 공진 Gap (H=18, 24, 30, 36㎜)중에서 공진 Gap (H)이 18m일 때 최대의 음향속도가 존재함을 알 수 있었고 진동자 표면부근에서부터 고정평판사이까지의 국소 최대 난류강도의 축 방향 위치에 따른 변화는 gap의 크기에 따라 8%∼70% 이었다. 전단응력값은 반경방향 위치의 중심영역에서 최대전단응력을 가지며 와도 분포도 반경방향 위치에서 진동자 중심영역에 최대 및 최소와도 값을 가짐을 알 수 있었다.

초음파 리니어 모터의 구동특성 (Driving characteristic of ultrasonic linear motor)

  • 김태열;김범진;박태곤;김명호;권오영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.204-207
    • /
    • 2000
  • An ultrasonic linear motor was composed of a slider and a stator vibrator including piezoelectric material and elastic material. The ultrasonic linear motors mainly consist of an ultrasonic vibrator which generates elliptical oscillations. L$_1$-B$_4$ ultrasonic linear motor use longitudinal and bending multi-vibration. In order to low driving voltage and improve the life time of the ultrasonic oscillator, we used stacked piezoceramics. Stacked piezoceramics are adhered to aluminum elastic material. The finite element method was used to optimize dimension of ultrasonic vibrator and direction of vibratory displacement. As a result of estimating the characteristics of the ultrasonic linear motor, no-load velocity was 2.04[m/s] when applied voltage was 70[V$\sub$rms/] in resonance frequency.

  • PDF

초음파 진동자를 이용한 족욕기용 구동회로 제작 및 특성 (Fabrication and charateristics of the foot-spa driving circuit using ultrasonic vibrator)

  • 장은성;김흥규;이상호;류주현;황락훈;정회승;정광현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.705-709
    • /
    • 2004
  • In this study, the foot-spa driving circuit using ultrasonic vibrator was manufactured The used ultrasonic vibrator was PSN-PMN-PZT ceramic with the radius of $25{\Phi}$ and the thickness of 2, 2.5, 3, 3.5 and 4mm, respectively. Resonent frequency for driving ultrasonic vibrator at the fabricated circuit was generated using the self exciting and the external exciting methods. Fabricated foot-spa showed the best condition at the resonent frequency of 1.130MHz and the ceramic thickness of 2.0mm. That is, when the foot-spa was operated for 360 min. at $0.5\ell$ water, temperature increase of water was $14^{\circ}C$ at the self exciting method and $16^{\circ}C$ at the external exciting methods, respectively.

  • PDF

X-Y 스테이지를 위한 초음파 리니터 모터의 설계 (Design of Ultrasonic Linear Motor for X-Y Stage)

  • 김태열
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.316-320
    • /
    • 2000
  • An ultrasonic linear motor was composed of a slider and a stator vibrator including piezoelectric material and elastic material. The ultrasonic linear motors mainly consist of an ultrasonic oscillator which generates elliptical oscillations. Elliptical oscillations are generated by synthesizing two degenerated modes. The design of a stator for an Ultrasonic linear motor was optimized with respect to vibration mode and direction of vibratory displacement by employing the finite element method. The motors were designed by varying the width of stator vibrator and the thickness, the length and the position of piezoceramics.

  • PDF

PIV를 이용한 초음파 진동에 의해 유도된 음향유동의 가시화 (Flow Visualization of Acoustic Streaming Induced by Ultrasonic Vibration Using Particle Imaging Velocimetry)

  • 노병국;권기정;이장연;이동렬
    • 한국소음진동공학회논문집
    • /
    • 제14권6호
    • /
    • pp.528-535
    • /
    • 2004
  • Ultrasonic Vibrator is designed to achieve the maximum vibration amplitude at 30 kHz by in-cluding a horn (diameter, 40 mm), mechanical vibration amplifier at the top of the ultrasonic vibrator in the system and making the complete system resonate. In addition, it is experimentally visualized by particle imaging velocimetry (PIV) that the acoustic streaming velocity in the gap is at maximum when the gap between the ultrasonic vibrator and stationary plate agrees with the multiples of half-wavelength of the ultrasonic wave. This fact results from the resonance of the sound wave and the theoretical analysis of that is also accomplished and verified by experiment. It is observed that the magnitude of the acoustic streaming dependent upon the gap between the ultrasonic vibrator and stationary plate possibly changes due to the measurement of the average velocity fields of the acoustic streaming induced by the ultrasonic vibration at resonance and non-resonance. There exists extremely small average velocity at non-resonant gaps while the relatively large average velocity exists at resonant gaps compared with non-resonant gaps. It also reveals that there should be larger axial turbulent intensity at the hub region of the vibrator and at the edge of it in the resonant gap where the air streaming velocity is maximized and the flow phenomena is conspicuous than that at the other region. Because the variation of the acoustic streaming velocity at resonant gap is more distinctive than that at non-resonant gap, shear stress increases more in the resonant gap and is also maximized at the center region of the vibrator except the local position of center (r〓0). At the non-resonant gap there should be low values of vorticity distribution, but in contrast to the non-resonant gap, high and negative values of it exist at the center region of the vibrator with respect to the radial direction and in the vicinity of the middle region with respect to the axial direction. Acoustic streaming is noise-free due to the ultrasonic vibration and maintenance-free because of the absence of moving parts. Moreover, the proposed method by acoustic streaming can be utilized to the nano and micro-electro mechanical systems as a driving mechanism in addition to the augmentation of the streaming velocity.

란쥬반형 진동자를 이용한 초음파 회전 모터에 관한 연구 (A Study of Ultrasonic Rotary Motor Using the Langevin Type Vibrator)

  • 이재형;박태곤;권오영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.223-227
    • /
    • 2003
  • In this study, ultrasonic rotary motors using a bolted langevin type ultrasonic vibrator were designed and fabricated. The stator vibrator has a longitudinal transducer section composed of two metal blocks and two piezoelectric ceramic elements (thickness-polarized) and a mode conversion metal block section called a torsion coupler. And, three kinds of motors were studied by finite element analysis and experiments. So, as material of torsion coupler which generate mode conversion of vibration copper, brass, and phosphor bronze were used. As a result, speed and torque were changed in proportion to the electrical input Voltage, but it was saturated in high voltage. And bad efficiency which was different from a expectation was measured in this motors. So, various problems should be improved for practical use. Finally, The motor which has 1 [cm] diameter was fabricated to present a possibility of miniaturization of this type motors.

  • PDF

유한요소해석 시뮬레이션을 이용한 평판형 $L_{1}-B){8}$ 모드 초음파 전동기의 최적 설계 (An Optimum Design of Flat-type $L_{1}-B){8}$ Mode Ultrasonic Motors Using FEM Simulation)

  • 우상호;김우태;신순인;김진수;사정우;김기수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.664-667
    • /
    • 2001
  • A flat-type L$_1$-B$_{8}$ Mode Ultrasonic motor(USM) uses longitudinal-bending multi-mode vibrator which is constructed with the metal-piezoceramic composite thin plate vibrator. Especially, the characteristics of vibrating displacement of the vibrator are important for the fabrication of USM. So, in this study, we tried to analyze them by the FEM(finite element method) simulation program. ANSYS 5.6 we used is a finite element software enabling the analysis of 2 or 3 dimensional structure of piezoelectric materials. Using this made us analyzing the resonance frequency and calculating displacement of vibrator and then the position of the projection.n.

  • PDF

란쥬반형 진동자의 유한요소해석 및 세라믹 적층특성 비교 (FEA of Langevin Type Ultrasonic Vibrator and Comparison of Stacking Characteristic of Ceramics)

  • 박민호;김태열;박태곤;김명호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.415-418
    • /
    • 2000
  • In this paper, we calculated equivalent circuit of Langevin type ultrasonic vibrator and designed a vibrator whose resonant frequency is 50(KHz). FEA (Finite Element Analysis) was employed to calculate the resonant frequencies and maximum displacements of designed vibrators. The computer calculated resonant frequencies were approached to the designed one. As AC voltage input the maximum displacements were shown sinusoidal changes. Terminal input admittance over a frequency range spanning the resonant frequency were calculated. ANSYS was employed to calculate resonant frequencies, displacements and terminal input admittance of vibrators

  • PDF