• Title/Summary/Keyword: Ultrasonic Signal

Search Result 638, Processing Time 0.022 seconds

A study for detection of melt flow zone about polyethylene butt fusion joints (폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구)

  • Kil, Seonghee;Kim, Younggu;Jo, NYoungdo;Lee, Yeonjae
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2016
  • Polyethylene pipes has useful benefits which are anti-corrosive and flexible material, so it is used to gas pipes but also class 3 water pipes of nuclear power plant, process pipes of petrochemical plant and chemical plant. So the usage of polyethylene pipes is widely increased. But it has been limited for the usage of polyethylene, because it can not be directly detected to fusion joints by using non destructive evaluation. Polyethylene pipes are connected by two methods, one is butt fusion and the other is electrofusion. Butt fusion is widely used to connecting the pipes. It is proposed to method for determining the reliability of joints in this study that is detection of the melt flow zone at fusion joints. In this study, middle density polyethylene is used, outside diameter of the test specimen is 225mm and thickness is 20.5mm. Speed of ultrasonic of this test specimen is 2,200m/s. Test specimens were fabricated by varying the heating time which means from 0% to 130% applying time through heating plate to polyethylene for detecting melt flow zone. Also 4 additional test specimens were made, one was made that not scrapping attached surface of pipes but applying 100% of the proper heating time and the others were made to include of soil, gravel and vinly tape paper at fusion joints, that were also applied 100% of proper heating time. Ultrasonic testing to measure the melt flow zone of 20 test specimens was conducted by using 3.5MHz and 5.0MHz ultrasonic probes and melt flow zone measuring was conducted to three times at different point to one specimen. To differentiate the melt flow zone signal, post image processing was equally conducted to all test results and image levels, contrast, sharpen, threshold were adopted to all teat results and the test results were displayed gray scale. From the results, for the shorter heating times the reflection area of multiple echo have been increased, so the data was obtained from the position where it can be eliminated as much as possible. At 80% of proper heating time(168 sec.), the signal of melt flow zone was obtained clearly, so measuring could be conducted. From 7% of proper heating time(15 sec.) to shorter heating times. we could not obtain the signal because test specimen was not fused. From the result, we can verify that measuring of melt flow zone by using phased array ultrasonic imaging method is possible. And we can verify to complete and incomplete butt fusion by measuring the melt flow zone.

Development of a Virtual Instrument System Using 3-demensional Acceleration Sensors and Digital Signal Processor (3차원 가속도 센서와 DSP를 응용한 가상 악기 시스템 개발)

  • Lee, Hui-Sung;Son, Dong-Kwan;Noh, Young-Hae
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.982-987
    • /
    • 2006
  • 고전의 관현악기에서부터 현대의 각종 전자악기까지, 인류는 그 문화와 시대의 변화에 따라 다양한 형태의 악기를 개발하고 활용하였다. 최근에는 전기전자 기술의 발달로 다양한 센서와 프로그램을 활용해서 여러 가지 음색과 효과를 내는 악기가 개발되고 있다. 그 중에서 사람의 움직임을 직접 감지해서 음악적 도구로 활용하는 기술이 주목 받고 있다. 이를 위해 터치 센서(touch sensor), 비젼 센서(vision sensor), 자기장 센서(magnetic sensor), 초음파 센서(ultrasonic sensor) 등이 응용되고 있다. 그러나 지금까지의 센서 기술로는 사람의 움직임과 관련된 위치, 속도, 가속도 등에 대한 정보를 직접 추출하기가 어렵고, 구현된 시스템도 공간의 제약을 받거나 혹은 구현된 부피가 크거나 복잡한 구성형태를 지니고 있는 문제점이 있었다. 그래서 본 논문에서는 사람의 움직임과 관련된 가속도 정보를 직접 감지해서 새로운 형태의 악기로 활용될 수 있는 시스템을 연구하고 개발하였다. 이를 위해 6개의 가속도 정보를 처리하는 기술과 DSP(Digital Signal Processor) 활용 기술, Max/MSP 활용 기술이 응용 되었으며, 소형의 시스템을 개발하기 위해 시그널 컨디셔닝(signal conditioning) 회로와 DSP 보드를 자체 개발하였다. 실험을 통해 사람의 움직임과 관련된 각종 정보가 적절한 소프트웨어의 활용으로 다양한 음색의 변화는 물론 음높이, 음량의 변화까지도 제어할 수 있음을 확인하였고, 새로운 형태의 악기로써 무대 공연이나 노래방 등에 폭넓게 활용될 수 있는 가능성을 확인하였다.

  • PDF

The Classification of U.T Defects in the Pressure Vessel Weld using the Pattern Recognition Analysis (형상인식을 이용한 압력용기 용접부 결함 특성 분류)

  • Shim, C.M.;Joo, Y.S.;Hong, S.S.;Jang, K.O.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.2
    • /
    • pp.11-19
    • /
    • 1993
  • It is very essential to get the accurate classification of defects in primary pressure vessel weld for the safety of nuclear power plant. The signal analysis using the digital signal processing and pattern recognition is performed to classify UT defects extracting feature vector from ultrasonic signals. The minimum distance classifier and the maximum likelihood classifier based on statistics were applied in this experiment to discriminate ultrasonics data obtained form both the training specimens (slit, hole) and the testing specimens(crack, slag). The classification rate was measured using pattern classifier. Results of this study show the promise in solving the many flaw classification problems that exist today.

  • PDF

A Study on the ultrasonic signals analysis for scan fish schools and seabed targets (어군 및 해저 목표물 탐지를 위한 초음파 신호분석에 관한 연구)

  • Kim Jae-Gab;Kim Won-Jung;Yang Hwa-Sup;Jeong Chan-Ju
    • Management & Information Systems Review
    • /
    • v.2
    • /
    • pp.95-106
    • /
    • 1998
  • Color Echo-sounder display signals reflected from underwater objects in eight colors according to the strength of the signal. When the sea bottom is hard due to the presence of rocks, etc, the trailing on the reflection become strong signal and soft to presence of mud, etc the trailing on the reflection become weak signal. Strong signals are displayed in the color range, reddish brown, orange and yellow, in descending order of intensity. Weak signals are displayed in the range blue, light blue, cyan and green, in ascending order of intensity. Image of fish schools at or near the sea bottom vary according to the characteristics of the beam angle setting. When the angle is wide, even fish not near the bottom may be recorded as being on the seabed. A narrow angle should, therefore, be selected when you want to get an accurate recording of fish at or near the sea bottom. The condition of the sea bottom can be determinded more easily when the beam angle is wide and pulse with is long. Though the objects could be verified by the type of reflected signals which have been transformed into digital signals strong middle and weak ones, the experiments have in continue under various condition. Futhermore, the methode of measuring temperature inside the sea ought to be examined.

  • PDF

Construction of Ultrasound Pulsed Doppler Velocimeter (펄스 초음파 도플러 속도계의 제작에 관한 연구)

  • 현석봉;김수용;이재수
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.25-39
    • /
    • 1994
  • To measure the velocity of heart wall and local flow transctaneously in blood vessels, we have developed a single channel 3.1 MHz pulsed ultrasonic Doppler velocity meter. Ultrasound pluse width and repetition frequency (PRF) used in the velocity meter is 1 ${\mu}$sec 6kHz reapectively, and the Doppler shift of the backscattered echo signal is sensed in a phase detector by coherent demodulation method. From the output of the phase detector, the Doppler signal corresponding to the mean velocity of acoustic wave scatterers over a small region is obtained by using a range gate, sample holder and band-pass filter. Mean frequency of Doppler signal is estimated by zero-crossing counter and the instantaneous velocity of scatters is displayed as a function of time. It is possible to estimate velocity profile, volume flow and flow acceleration of vessels in man if the number of channels and range resolution in increased.

  • PDF

The Design & Manufacture of Multi-coil Eddy Current Sensor and Characteristic Analysis (다중코일 와전류 센서 설계제작 및 특성분석)

  • Ahn, Y.S.;Gil, D.S.;Park, S.G.
    • Journal of Power System Engineering
    • /
    • v.15 no.3
    • /
    • pp.65-69
    • /
    • 2011
  • This paper introduces the multi-coil eddy current sensor and its characteristic in magnetic material gas turbine rotor. In the past, magnetic particle inspection method was used for qualitative defect evaluation in magnetic material gas turbine rotor. And the ultrasonic inspection method was used for quantitative defect evaluation. Nowadays, eddy current method is used in magnetic gas turbine rotor inspection due to advanced sensor design technology. We developed multi-coil eddy current sensor for the rotor dovetail inspection. At first, rotor stress is analyzed for the determination of sensor position and number. The sensor coils are designed to cover the stress concentration area of rotor dovetail. We select optimum frequency according to material standard penetration data and experiment results. The rotor mock-up and artificial defects were made for the signal detection and resolution analysis of multi-coil eddy current sensor. The results show that signal detection and resolution capabilities are enhanced in comparison to the commercialized sensor enough for the gas turbine rotor inspection. So, this developed multi-coil eddy current sensor substituted for commercialized one and it applied in real gas turbine rotor inspection.

Proposal of a non-coherent Communication Protocol with Ultra Sonic which can Improve the Communication Speed (넌코히어런트 전송 방식에서 초음파를 이용한 디지털 통신속도 개선 프로토콜 제안)

  • Yoon, Byung-Woo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Propagation of electromagnetic wave in the water or underground is very difficult because of the conductivity of the propagation materials. In this case, we usually use acoustic signal as ultrasonic but, it is not easy to transfer long distance with coherent method because of time varying multipath, doppler effect, and attenuations. So, we use noncoherent method as FSK to communicate between long distances. But, as the propagation speed of acoustic sound is very slow, the BW of the channel is narrow. It is very hard to guaranty the enough speed of communication like digital image data. In this paper, we proposed a new data communication protocol which can transmit multi-bit digital data with every single ping, and improve the data communication speed in the water.

  • PDF

spatial coordinate analysis using IR-UWB Radar (IR-UWB Radar 를 이용한 공간좌표 분석)

  • Lim, Jae-jun;kim, Min;Byun, Gi-sig;Kim, Gwan-hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.733-734
    • /
    • 2017
  • Ultrasonic, infrared, and CCD cameras are typically used to obtain location information, but the error range is large depending on the surrounding environment. However, IR-UWB can be used for distance and location measurement both indoors and outdoors, Technology. It is possible to determine the existence and distance of an object by emitting a short signal width in units of 1 ns and using a reflected signal and a time delay. It is also possible to measure the exact position within the cm error irrespective of the environmental conditions. Since it processes a large number of reflection signals, we try to measure three-dimensional spatial coordinates by improving the noise by using the mean value of the signal, the band pass filter and the FFT.

  • PDF

Laser based impedance measurement for pipe corrosion and bolt-loosening detection

  • Yang, Jinyeol;Liu, Peipei;Yang, Suyoung;Lee, Hyeonseok;Sohn, Hoon
    • Smart Structures and Systems
    • /
    • v.15 no.1
    • /
    • pp.41-55
    • /
    • 2015
  • This study proposes a laser based impedance measurement system and impedance based pipe corrosion and bolt-loosening monitoring techniques under temperature variations. For impedance measurement, the laser based impedance measurement system is optimized and adopted in this paper. First, a modulated laser beam is radiated to a photodiode, converting the laser beam into an electric signal. Then, the electric signal is applied to a MFC transducer attached on a target structure for ultrasonic excitation. The corresponding impedance signals are measured, re-converted into a laser beam, and radiated back to the other photodiode located in a data interrogator. The transmitted impedance signals are treated with an outlier analysis using generalized extreme value (GEV) statistics to reliably signal off structural damage. Validation of the proposed technique is carried out to detect corrosion and bolt-loosening in lab-scale carbon steel elbow pipes under varying temperatures. It has been demonstrated that the proposed technique has a potential to be used for structural health monitoring (SHM) of pipe structures.

Analysis of Defect in CANDU Feeder Pipe using Phased Array Ultrasonic Inspection System (냉각재 공급자관 위상배열 검사 적용에 따른 결함 분석)

  • Lee, Sang-Hoon;Jin, Seuk-Hong;Kim, In-chul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.78-82
    • /
    • 2010
  • The feeder pipe of Main Primary Heat Transfer System in Wolsong Nuclear Power Plant was inspected by the Ultrasonic Phase Array technique in 2010. It is the first time to apply this method to the construction at Nuclear Power Plant in Korea. The time required for UT technique is less than RT method. The UT method doesn't need to evacuate personnel who works nearby inspecting area and doesn't need to wait developing of film. For these reasons, the UT method is the fastest method among the volumetric inspections. As a result of the examination, it became clear that main defect of the feeder pipe is the Lack of fusion in the welded area. Moreover, the rate of defect was reduced gradually as improvement of welder's skill. If welding machine has problem, the defect has tended to same pattern(occurred same position in the welding area) but these defects were founded without specific rules. For these reasons, the creation of defect is dependent on the skill of worker not on the automatic welding machine. This evaluation of defect signal and collecting data would be useful to further examination in ISI.

  • PDF