• Title/Summary/Keyword: Ultrasonic Signal

Search Result 638, Processing Time 0.028 seconds

Speech synthesis using acoustic Doppler signal (초음파 도플러 신호를 이용한 음성 합성)

  • Lee, Ki-Seung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.2
    • /
    • pp.134-142
    • /
    • 2016
  • In this paper, a method synthesizing speech signal using the 40 kHz ultrasonic signals reflected from the articulatory muscles was introduced and performance was evaluated. When the ultrasound signals are radiated to articulating face, the Doppler effects caused by movements of lips, jaw, and chin observed. The signals that have different frequencies from that of the transmitted signals are found in the received signals. These ADS (Acoustic-Doppler Signals) were used for estimating of the speech parameters in this study. Prior to synthesizing speech signal, a quantitative correlation analysis between ADS and speech signals was carried out on each frequency bin. According to the results, the feasibility of the ADS-based speech synthesis was validated. ADS-to-speech transformation was achieved by the joint Gaussian mixture model-based conversion rules. The experimental results from the 5 subjects showed that filter bank energy and LPC (Linear Predictive Coefficient) cepstrum coefficients are the optimal features for ADS, and speech, respectively. In the subjective evaluation where synthesized speech signals were obtained using the excitation sources extracted from original speech signals, it was confirmed that the ADS-to-speech conversion method yielded 72.2 % average recognition rates.

A Development of Acoustic Release System in the Seafloor (심해저용 원격 착탈 제어 시스템의 개발)

  • Kim, Young-Jin;Huh, Kyung-Moo;Jeong, Han-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.9
    • /
    • pp.774-780
    • /
    • 2005
  • For the accurate inspection of the resources and space in the ocean, the method of locating the measurement equipments in the seafloor and retrieving these equipments later after a certain period of time. is generally used. In this method, the reliability of retrieving measurement equipments is very important. In our proposed remotely-controlled acoustic release system, an underwater ultrasonic wave recognition algorithm by which we can recognize the sound signal without the influence of disturbances due to underwater environment changes is developed, and a battery is used for the reduction of electric power consumption. we show the effectiveness of our proposed system through experimental results.

A Spatial Average Method Using 2nd Order Sampling in Ultrasonic Doppler System (초음파 도플러 시스템에서 2차 샘플링을 이용한 공간축상의 평균 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.279-288
    • /
    • 1995
  • Ultrasonic Doppler systems for the purpose of estimating blood flow velocity, blood flow volume, and flow imaging are commonly used due to advantages of non-invasive and real time observation. Specially, the technical developments of color flow mapping (2-D Doppler) systems have made a relatively rapid progress. However, the 2-D Doppler systems have several problems, such as the range ambiguity, low signal to noise ratio, and slow frame rate. The slow frame rate problem is resolved by using the spatial average which is a method to acquire more data samples for mean frequency estimation. In this paper, spatial average method using the 2nd order sampling instead of quadrature sampling is proposed. The experimental results show that the proposed methods have good performance and easy application to the color flow mapping system.

  • PDF

Edge Detection of Sonogram Using Sobel Operator (Sobel 연산자를 이용한 초음파 영상의 경계선 검출)

  • Choi, Gui-Rack;Lee, Jun-Hang
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.17-21
    • /
    • 2008
  • Image quality is improved if the high frequency domains of boundary surface are made distinct. We suggested a method of correcting indistinct defects in ultrasonic images resulting from dynamic imaging. According to the results of the experiment, boundaries in input ultrasonic images became distinct. However, we need to solve the problem that information on pixels of low signal intensity adjacent to boundaries is lost because high-frequency components in the boundaries are strong.

  • PDF

Biomaterials toward Future Medicine

  • Sakurai, Yasuhisa
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.117-118
    • /
    • 1986
  • It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization.

  • PDF

Development of Portable Arrhythmia Moniter Using Microcomputer(I) (마이크로 컴퓨터를 이용한 휴대용 부정맥 모니터의 개발(I)-하드웨어 설계를 중심으로-)

  • 이명호;안재봉
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.169-182
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

Harvesting energy from acoustic vibrations of conventional and ultrasonic whistles

  • Hattery, Rebecca;Bilgen, Onur
    • Smart Structures and Systems
    • /
    • v.19 no.6
    • /
    • pp.615-624
    • /
    • 2017
  • This paper experimentally investigates the feasibility of harvesting vibration energy from whistles using piezoelectric materials. The end goal of this research is to generate sufficient power from the whistle to power a small radio transmitter to relay a basic signal - for example, a distress call. First, the paper discusses the current literature in energy harvesting from acoustic resonance. Next, the concept of an active whistle is presented. Next, results from energy harvesting experiments conducted on conventional and ultrasonic whistles undergoing human-actuation and actuation by a pressure-regulated air supply are presented. The maximum power density of the conventional whistle actuated by a human at 100 dB sound pressure level is $98.1{\mu}W/cm^3$.

Suppression of Speckle in ultrasonic image by Phase Filtering (위상필터를 사용한 초음파 영사에서의 반점 제거)

  • Kim, D.;Greenleaf, J.F.;Oh, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.11
    • /
    • pp.5-10
    • /
    • 1990
  • The object detection capabilities of ultrasonic imaging systems are limited by the ability of the detection process to distinguish the resolved object signals from backscattered speckle noise. It has been shown that the phase component of the Fourier transform of the speckle noise is random. Based on this property. we propose a new algorithm for distinguishing between speckle and specular targets. The proposed algorithm is implemented by taking the Fourier transform of the received signal, low-pass filtering the phase, and taking the inverse Fourier transform of the filtered phase to enhance specular reflectors and reduce speckle in the image. Simulations and experiments using phantoms confirm the algorithm yielding significant reduction of speckle noise.

  • PDF

Resonution Enhancement of Ultrasonic B-Scan Images by Deconvolution (횡축 디콘벌루션에 의한 초음파 B 스캔 연상의 해상력 향상)

  • Jeong, Joon-Young;Chin, Young-Min;Woo, Kwang-Bang
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.445-449
    • /
    • 1988
  • Digital processing of measured data offers a powerful means to improve the resolution and quality of ultrasonic imaging. The present research demonstrates that filtering typical B-scan images using Wiener filter enhances lateral resolutions by more than 50 percent. The filter is operated using the measured signal amplitude across the transmitter beam and the beam with. It is optimized for low noise and high resolution By an empirical approach. This bethod for lateral filtering produces a very useful result for the line images with high interference by neighboring lines.

  • PDF

A Separator system for underwater observing instrument (수중 관측 및 탐사장비 원격분리 시스템의 개발)

  • Kim, Young-Jin;Jeong, Han-Cheol;Huh, Kyung-Moo;Cho, Young-June
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.158-160
    • /
    • 2005
  • In order to successfully exploit underwater resources, the first step would be a marine environmental research and exploration on the seafloor. Traditionally one sets up a long-term underwater experimental unit on the seafloor and retrieves the unit later after a certain period time. Essential to these applications is the reliable teleoperation and telemetering of the unit. In our proposed ultrasonic-wave remote control system and an underwater sound recognition algorithm that can identify the sound signal without the influence of disturbances due to underwater environmental changes. The proposed method provides a means suitable for units which require low power dissipation and long-time underwater operation. We demonstrate its ability of securing stability and fast sound recognition through experimental methods.

  • PDF