• Title/Summary/Keyword: Ultrasonic Resonance

검색결과 191건 처리시간 0.023초

초음파 절삭기 핸드피스부 제작 및 변위 특성 시뮬레이션 (Fabrication and Simulation of Displacement Properties of Ultrasonic Generator Handpiece)

  • 김승원;류주현;이지영
    • 한국전기전자재료학회논문지
    • /
    • 제31권3호
    • /
    • pp.152-155
    • /
    • 2018
  • Ultrasonic wave technologies have been widely used in ultrasonic washing machines, ultrasonic surgery, ultrasonic welding machines, ultrasonic sensors, and medical instruments. Ultrasonic surgery can be realized through the cavitation effect of ultrasonic waves. In this study, piezoelectric ceramics were manufactured to achieve the optimum design of a piezoelectric vibrator in a handheld generator for ultrasonic surgery. The best specimen showed the excellent piezoelectric properties of kp=0.624, Qm=1,531, and $d_{33}=356pC/N$. Numerical modeling based on the finite element method was performed to find the resonance frequency, the anti-resonance frequency, and the displacement properties of the handheld ultrasonic generator. Maximum displacement was observed in the six-step piezoelectric vibrator at $6.36{\mu}m$.

플립칩 접합용 초음파 혼의 목표 주파수와 모드를 고려한 2차원 및 3차원 위상최적화 설계 (2D and 3D Topology Optimization with Target Frequency and Modes of Ultrasonic Horn for Flip-chip Bonding)

  • 하창용;이수일
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.84-91
    • /
    • 2013
  • Ultrasonic flip-chip bonding needs a precise bonding tool which delivers ultrasonic energy into chip bumps effectively to use the selected resonance mode and frequency of the horn structure. The bonding tool is excited at the resonance frequency and the input and output ports should locate at the anti-nodal points of the resonance mode. In this study, we propose new design method with topology optimization for ultrasonic bonding tools. The SIMP(solid isotropic material with penalization) method is used to formulate topology optimization and OC(optimal criteria) algorithm is adopted for the update scheme. MAC(modal assurance criterion) tracking is used for the target frequency and mode. We fabricate two prototypes of ultrasonic tools which are based on 3D optimization models after reviewing 2D and 3D topology optimization results. The prototypes are satisfied with the ultrasonic frequency and vibration amplitude as the ultrasonic bonding tools.

2-유체 분무에서 액체미립화에 대한 초음파의 영향에 관한 연구 (A Study on Ultrasonic Effects for the Atomization in a Twin-Fluid Spray)

  • 주은선;정진도;송민근
    • 한국분무공학회지
    • /
    • 제3권4호
    • /
    • pp.50-57
    • /
    • 1998
  • The utilization of resonance should be considered to get the maximum effect of ultrasonic to atomize liquid. The ultrasonic generator, transducer, horn, and all attached parts are used to produce the resonance, and specially the characteristics of liquids such as liquid load, property, and etc., for the liquid atomization affinity are considered. In this study, the variable device of liquid load was made and distilled water and city water selected as experimental liquids were sprayed by a twin-fluid spray method and their diameters, distributions, and spray quantum of spray droplets were measured by the light scattering system. And all data were observed, compared and considered relatively. In results, a lot of phenomena of liquid atomization affinity by ultrasonic appeared in accordance with liquid loads, namely head h.

  • PDF

공진형 인버터를 사용한 적층액츄에이터형 초음파 노즐 구동시스템의 전기적 특성 (Electrical Properties of Multilayer Actuator Structured-ultrasonic Nozzle Driving System using a Resonant Inverter)

  • 황락훈;김화수;김국진;류주현
    • 한국전기전자재료학회논문지
    • /
    • 제20권11호
    • /
    • pp.953-958
    • /
    • 2007
  • In this paper, multilayer actuator structured-ultrasonic nozzle and resonant inverter driving circuit were manufactured, respectively. Its electrical properties were investigated. Multilayer actuator structured ultrasonic nozzle was fabricated using PMN-PNN-PZT ceramics showing excellent piezoelectric characteristics. In order to drive ultrasonic nozzle, resonant PWM inverter was used. The purpose of this study is to find the optimal driving condition of ultrasonic nozzle. Accordingly, electrical and temperature characteristic of multilayer ultrasonic driving system were investigated by experiments as a function of the series resonance inductance. The driving current of ultrasonic nozzle showed the maximum current of 27 mA. Also, the surface temperature of ceramic vibrator showed $44^{\circ}C$ at driving time for 20 min. The ultrasonic nozzle was stably operated in the case of driving for more than 20 min.

초음파의 가시화에 의한 진동자의 공진주파수 측정에 관한 연구 (The Measurement of the Resonance Frequency of Transducer by Ultrasonic Visualization)

  • 이범성;한응교;송창섭
    • 비파괴검사학회지
    • /
    • 제13권3호
    • /
    • pp.14-23
    • /
    • 1993
  • 가시화 시험을 통하여 시험편에 부착된 초음파 진동자의 공진주파수의 측정을 시도하였다. 그 결과 시험편에 부착되어 있는 진동자의 공진주파수는 진동자 자체만의 공칭 공진주파수 보다 훨씬 낮게 나타났고, 그 정도는 주파수가 높은 진동자일수록 심하게 나타나는 것을 볼 수 있었는데, 이론적인 해석에 의한 검증 결과 그 원인이 진동자 보호용 알루미늄 판재의 공진에 의한 것으로 판명되었다.

  • PDF

진행파 회전형 초음파 모터의 가압력과 구동전압에 따른 공진특성의 변화 분석 (The analysis of the resonance characteristics of a traveling wave type ultrasonic motor by applying the normal force and driving voltage)

  • 오진헌;박철현;임기조;김현후
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.324-324
    • /
    • 2008
  • Piezoelectric ceramics is an active element that makes stator to vibrate to generate rotational force in ultrasonic motors. In drive of ultrasonic motors, many factors that affect to the resonance characteristics of piezoelectric ceramics exist. For example, those factors are bonding condition with elastic body, the magnitude of electric field, the normal force for frictional drive and the emission of heat due to vibration and friction and so on. Therefore, it is important to research the inclination of property variation of piezoelectric ceramics in circumstance that has complex elements. In this paper, we focused and analyzed the resonance characteristics of ultrasonic motor due to the magnitude of the driving voltage and normal force.

  • PDF

초음파원자현미경을 이용한 나노스케일 박막 코팅층에 대한 탄성특성 평가 (Evaluation of Elastic Properties for Nanoscale Coating Layers Using Ultrasonic Atomic Force Microscopy)

  • 곽동열;조승범;박익근
    • 한국생산제조학회지
    • /
    • 제24권5호
    • /
    • pp.475-480
    • /
    • 2015
  • Ultrasonic atomic force microscopy (Ultrasonic-AFM) has been used to investigate the elastic property of the ultra-thin coating layer in a thin-film system. The modified Hertzian theory was applied to predict the contact resonance frequency through accurate theoretical analysis of the dynamic characteristics of the cantilever. We coat 200 nm thick Aluminum and Titanium thin films on the substrate using the DC Magnetron sputtering method. The amplitude and phase of the contact resonance frequency of a vibrating cantilever varies in response to the local stiffness constant. Ultrasonic-AFM images were obtained using the variations in the elastic property of the materials. The morphology of the surface was clearly observed in the Ultrasonic-AFM images, but was barely visible in the topography. This research demonstrates that Ultrasonic-AFM is a promising technique for visualizing the distribution of local stiffness in the nano-scale thin coatings.

유한요소 해석을 이용한 초음파원자현미경 캔틸레버의 접촉 공진주파수 특성 분석 (Analysis of Contact Resonance Frequency Characteristics for Cantilever of Ultrasonic-AFM Using Finite Element Method)

  • 이주민;한유하;곽동열;박익근
    • 한국생산제조학회지
    • /
    • 제23권5호
    • /
    • pp.478-484
    • /
    • 2014
  • Ultrasonic atomic force microscopy(Ultrasonic-AFM) can be used to obtain images of the elastic properties of a subsurface and to evaluate the elastic properties by measuring the contact resonance frequency. When a tip is in contact with the sample, it is necessary to understand the cantilever behavior and the tip-sample interaction for the quantitative and reliable analysis. Therefore, precise analysis models that can accurately simulate the tip-sample contact are required; these can serve as good references for predicting the contact resonance frequency. In this study, modal analyses of the first four modes were performed to calculate the contact resonance frequency by using a spring model, and the deformed shapes of the cantilever were visualized at each mode. We presented the contact characteristics of the cantilever with a variety of contact conditions by applying the contact area, contact material thickness, and material properties as the parameters for the FEM analysis.

A Study on the Detection Algorithm of an Advanced Ultrasonic Signal for Hydro-acoustic Releaser

  • Kim, Young-Jin;Huh, Kyung-Moo;Cho, Young-June
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권5호
    • /
    • pp.767-775
    • /
    • 2008
  • Methods used for exploring marine resources and spaces include positioning a probe under water and then recalling it after a specified time. Hydro-acoustic Releasers are commonly used for positioning and retrieving of such exploration equipment. The most important factor in this kind of system is the reliability for recalling the instruments. The frequently used ultrasonic signal detection method can detect ultrasonic signals using a fixed comparator, but because of increased rates of errors due to outside interferences, information is repetitively acquired. This study presents an effective ultrasonic signal detection algorithm using the characteristics of a resonance and adaptive comparator Combined with the FSK+ASK modulator. As a result, approximately 8.8% of ultrasonic wave communication errors caused by background noise and transmission losses were reduced for effectively detecting ultrasonic waves. Furthermore, the resonance circuit's quality factor was enhanced (Q = 120 to 160). As such, the bias voltage of the transistor (Vb= 3.3 to 6.8V) was increased thereby enhancing the frequency's selectivity.

와이어 본딩용 초음파 공구혼 설계에 관한 연구 (Design of Ultrasonic Tool Horn for Wire Wedge Bonding)

  • 이봉구;오명석;마정범
    • 한국생산제조학회지
    • /
    • 제22권4호
    • /
    • pp.717-722
    • /
    • 2013
  • In this study, we investigated the design of a wire wedge bonding ultrasonic tool horn using finite element method (FEM) simulations. The proposed method is based on an initial design estimate obtained by FEM analysis. An ultrasonic excitation causes various vibrations of a transducer horn and capillary. A simulated ultrasonic transducer horn and resonator are then built and characterized experimentally using a laser interferometer and electrical impedance analyzer. The vibration characteristics and resonance frequencies close to the exciting frequency are identified using ANSYS. FEM analysis is developed to predict the resonance frequency of the ultrasonic horn and use it in the optimal design of an ultrasonic horn mode shape.