• Title/Summary/Keyword: Ultrasonic Pulse-Echo Method

Search Result 91, Processing Time 0.021 seconds

Application of Thin-Walled Tubes Using Guided Wave (유도초음파를 이용한 대구경 배관 적용에 관한 연구)

  • Park, S.K.;Lee, Y.H.
    • Journal of Power System Engineering
    • /
    • v.12 no.1
    • /
    • pp.58-65
    • /
    • 2008
  • A method to test thin-walled tubes by guided ultrasonic wave is reported. The principle is that applicate two types of axially symmetric ultrasonic tube modes and "longitudinal" modes with particle displacement, which is coupled in axial and radial directions for transverse failures and torsional modes, oscillating in the circumferential direction only, for longitudinal failures. Both types of modes propagate along the tube in the axial direction. Therefore, a pulse-echo technique is possible. The pulses are excited and received at one end of the tube without contact electro-dynamic transducers. As soon as the tubes is put into a transducer coil at one end, the test of the whole tube can be accomplished in a few milliseconds. It is not necessary to rotate and transport the tubes during the test.

  • PDF

The Effects of the Internal Losses of a Piezoelectric Ultrasonic Transducer on Its Performances (압전형 초음파 Transducer의 내부 손실이 그 성능에 미치는 영향)

  • Ih, Jong Hyun;Lee, Byung Ho;Park, Song Bai
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.4
    • /
    • pp.515-521
    • /
    • 1986
  • Performances of a piezoelectric ultrasonic transducer are analyzed considering the internal losses of a piezoleelctric material and fabricated layers. The KLM-model is adopted for the equivalent circuit of a piezoelectric resonator, and the attenuation coefficient is introduced to represent the internal losses of the transducer. The attenuation coefficient of a piezoelectric resonator is inversely proportional to the maximum value of the input electrical resistance, and is confirmed to be an efficient parameter for the analysis of the considerable lossy piezo-electric resonator operating in a thickness mode. Also, the experimentla RTII is obtained by pulse-echo method. The experimental result is deviated from the predicted one within 3 dB over the 20dB frequency bandwidth.

  • PDF

Material Evaluation of Lead Die-Casted Positive Grid for Battery Using Nondestructive Evaluation Technique (연축전지 양극기판의 기계적 특성비교 분석 및 비 파괴 평가기법의 적용)

  • Kim, Hui-Jung;Lee, Min-Rae;Lee, Jun-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.8
    • /
    • pp.1709-1718
    • /
    • 2002
  • It is well recognized that improving capacity of positive grid in battery is one of key factors for controlling the expected long lift-time of Battery Energy Storage System(B.E.S.S). Thus it is really important to characterized material properties of positive grid which are mainly affected by fabrication process. In this study, two kinds of positive grids, which were fabricated by gravity casting and die-casting technique were used. Micro-structural observation and tensile test were conducted to investigate the effect of fabrication process of positive grid. Ultrasonic measurement based on pulse-echo method and ultrasonic C-scan technique also performed to correlate ultrasonic velocity with porosity ratio in positive grid. It was found that the porosity ratio of grid fabricated by gravity casting technique increased significantly compared to the grid fabricated by die-casting technique. It was also shown that ulrasonic technique is effective to evaluate the porosity ratio in positive grid.

Detection of Laser Generated Ultrasonic Wave Using Michelson Interferometer (마이켈슨 간섭계를 이용한 레이저 여기 초음파의 검출)

  • Kim, Kyung-Cho;Yamawaki, Hisashi;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.27-32
    • /
    • 2000
  • In this paper, ultrasonic wave in the thermoelastic regime was generated in a steel disk by illuminating a pulse laser (Q-switched Nd:YAG) on the surface of the sample and was detected on the other side by Michelson interferometer which was stabilized by feed back control. The experimentally detected displacement waveform of the ultrasonic wave showed good agreement with the theoretically expected one. Also it was shown that sound speeds of longitudinal and shear wave were similar to ones measured by pulse-echo method using a contact transducer. As an application of the noncontact ultrasonic measurement by using laser based ultrasonics, the sound speed in the sample was monitored while the sample was heated in a furnace, and the result showed that it decreased according to the increase of sample temperature.

  • PDF

Ultrasonic Velocity and Absorption Measurements for poly (sodium 4-styrenesulfonate) and Water Solutions (Poly (sodium 4-styrenesulfonate)/ 물 이성분용액의 초음파 음속 및 흡수계수측정)

  • 배종림
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.7
    • /
    • pp.497-502
    • /
    • 2004
  • Both ultrasonic velocity at 3 MHz and absorption coefficient in the frequency range of 0.2-2 MHz were measured for poly (sodium 4-styrenesulfonate) aqueous solution over the concentration range of 5 to 25 % by weight. Pulse echo overlap method was employed to measure the ultrasonic velocity over the temperature range of 10-90 ℃ and the high-a ultrasonic resonator method was used for the absorption coefficient measurement at 20 ℃. The velocity exhibited a maximum value at approximately 55. 59, 63. 67, and 71 ℃ in 25, 20. 15, 10. and 5 wt% solutions, respectively. The velocity increased with poly (sodium 4-styrenesulfonate) concentration at a given temperature. The concentrations dependences of the relaxation frequency and amplitude showed that the relaxation around 200 kHz is related to the structural fluctuations of polymer molecules, such as the segmental motions of the polymer chains and that around 1 MHz resulted from the proton transfer reaction of the oxygen sites of SO₃. Both the absorption and the shear viscosity increase with the Polymer concentration. but decrease with temperature.

Analysis of Ultrasonic Scattering Fields by 2-D Boundary Element Method and Its Application (2차원 경계요소법에 의한 초음파 산란음장의 해석과 응용)

  • Jeong, Hyunjo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.11 s.242
    • /
    • pp.1439-1444
    • /
    • 2005
  • A two-dimensional boundary element method was used for the scattering analysis of side-drilled hole(SDH). The far-field scattering amplitude was calculated for shear vertical(SV) wave, and their frequency and time-domain results were presented. The time-domain scattering amplitude showed the directly reflected wave from the SDH leading edge as well as the creeping wave. In an immersion, pulse-echo testing, two measurement models were introduced to predict the response from SDHs. The 2-D boundary element scattering amplitude was converted to the 3-D amplitude to be used in the measurement model. The receiver voltage was calculated fer SV wave incidence at 45$^{\circ}C$ on the 1 m diameter SDH, and the result was compared with experiment.

Evaluation of the Surface Crack by a Large Aperture Ultrasonic Probe (대구경 초음파 탐촉자를 이용한 표면균열 평가)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.180-185
    • /
    • 2004
  • Conventional ultrasonic examination to detect micro and small surface cracks is based on the pulse-echo technique using a normal immersion focused transducer with high frequency, or an angle-beam transducer generating surface waves. It is difficult to make an automatic ultrasonic system that can detect micro and small surface cracks and position in a large structure like steel and ceramic rolls, because of the huge data of inspection and the ambiguous position data of the transducer. In this study, a high-precision scanning acoustic microscope with a 10MHz large-aperture transducer has been used to assess the existence, position and depth of a surface crack from the real-time A, B, C scans obtained by exploiting the ultrasonic diffraction. The ultrasonic method with large aperture transducer has improved the accuracy of the crack depth assessment and also the scanning speed by ten times, compared with the conventional ultrasonic methods.

A Pulse-Echo Testing Model for Partially Damaged Ultrasonic Transducers (부분 손상을 입은 초음파 탐촉자의 펄스-에코 시험 모델)

  • Song, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.2
    • /
    • pp.95-108
    • /
    • 1996
  • In ultrasonic testing, flaw signal from which quantitative information on flaws is determined is influenced by 3 factors : (1) the incident wavefield.produced by the transducer, (2) the scattered waves produced by flaws, and (3) the reception of the scattered waves back at the transducer. So even small changes in transducer performance due to aging or unexpected damages can produce the changes in the characteristics of flaw signal and finally the changes in the quantitative information on flaws. Thus a reliable calibration method of transducer performance is desired. Recently, theoretical models for ultrasonic testing have been employed as reference standards for the calibration of transducers which are considered as circular planar piston sources in the most of cases. But this simplification cannot be applied to partially damaged transducer which has lost their symmetry in performance, even not in appearance. Unfortunately there has been no reliable practical model which can be used for the calibration of partially damaged transducers. Here a pulse-echo testing model for partially damaged ultrasonic transducers was developed with experimental verification. The experimental responses agree very well with the theoretical prediction. So we expect that this model can be served as a theoretical reference standards for transducer calibration.

  • PDF

The Features Extraction of Ultrasonic Signal to Various Type of Defects in Solid (고체내부의 결함형태에 따른 초음파 신호의 특징추출)

  • Shin, Jin-Seob;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.62-67
    • /
    • 1995
  • In this paper, the features extraction of reflected ultrasonic signals from various type of defects existing in Al metal has been studied by digital signal processing. Since the reflected signals from various type of the defects are ambiguous in features distinction from effects of noise, Wiener filtering using AR (auto-regressive) technique and least-absolute-values norm method has been used in features extraction and comparison of signals. In this experiment, three types of the defect in aluminum specimen have been considered: a flat cut, an angular cut, a circular hole. And the reflected signal have been measured by pulse-echo methods. In the result of digital signal processing of the reflected signal, it has been found that the features extraction method have been effective for classification of the reflected signals from various defects.

  • PDF

Development of Ultrasonic Testing Method for Evaluation of Adhesive Layer of Blaster Tube (토출관 접합계면 평가를 위한 초음파 시험법 개발)

  • Kim, Y.H.;Song, S.J.;Park, J.S.;Cho, H.;Lim, S.Y.;Yun, N.G.;Park, Y.J.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.2
    • /
    • pp.46-53
    • /
    • 2004
  • Ultrasonic testing method has been developed to evaluate flaw of adhesive layers in blast tube for the reliability of the rocket nozzle. The ultrasonic reflection from the interface between the steel sheet and the epoxy adhesive is measured with a high-frequency Pulse-echo setup in order to identify contact debonding and missing adhesive in epoxy layer between steel and FRP layers. The steel sheet is resonated by low-frequency ultrasound, and the gap size underneath the measuring location is estimated from the resonance responses. For practical application in industry an automated testing system has been developed where the proposed approach is implemented. The performance of the proposed approach has been verified by actual measurement of gap sizes from the cross-sections of cut specimens using an optical microscope.