전립선암의 온열치료를 위한 초음파변환기 개발에 관한 연구 (A study for implementation of ultrasonic transducer in the prostate cancer hyperthermia)

  • 박문규;노시철;박재현;최흥호
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.377-384
    • /
    • 2009
  • The ultrasonic hyperthermia for oncology has been developed and studied. The HIFU(high intensity focused ultrasound) is the most recent method to treat the tumor by using ultrasound. In this study, an insertion-type transducer for treating a prostate cancer, which can focus the ultrasonic beam mechanically and electrically, was designed and developed. The developed transducer was composed of three arrays, and each array has 32 elements. For the purpose of the mechanical focusing, both side arrays are slanted to the center array by $15^{\circ}$. With this structure, NFL(near field length) was set up as 30 mm. The PZT-4 and two matching layers were used, and the backing layer was excepted to prevent energy losses. The acoustic field analysis and the heating test were performed to evaluate the performance of developed transducer. The shape of an acoustic field, peak pressure, and acoustic pressure distribution were compared with numerical simulation. The NFL was 32 mm, the beam width was 5 mm, focal area was $40\;mm^2$, and peak pressure was 5.5 MPa. With heating by using developed transducer, the temperature increased up to $33^{\circ}C$ at focal zone. As a result of this study, the usefulness of suggested transducer for prostate cancer hyperthermia was confirmed by the acoustic field analysis and the heating test with TMM(tissue mimicking) phantom.

인공지능을 활용한 초음파영상진단장치에서 초음파 팬텀 영상을 이용한 정도관리의 정량적 평가방법 연구 (A Study on the Quantitative Evaluation Method of Quality Control using Ultrasound Phantom in Ultrasound Imaging System based on Artificial Intelligence)

  • 임연진;황호성;김동현;김호철
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권6호
    • /
    • pp.390-398
    • /
    • 2022
  • Ultrasound examination using ultrasound equipment is an ultrasound device that images human organs using sound waves and is used in various areas such as diagnosis, follow-up, and treatment of diseases. However, if the quality of ultrasound equipment is not guaranteed, the possibility of misdiagnosis increases, and the diagnosis rate decreases. Accordingly, The Korean Society of Radiology and Korea society of Ultrasound in Medicine presented guidelines for quality management of ultrasound equipment using ATS-539 phantom. The DenseNet201 classification algorithm shows 99.25% accuracy and 5.17% loss in the Dead Zone, 97.52% loss in Axial/Lateral Resolution, 96.98% accuracy and 20.64% loss in Sensitivity, 93.44% accuracy and 22.07% loss in the Gray scale and Dynamic Range. As a result, it is the best and is judged to be an algorithm that can be used for quantitative evaluation. Through this study, it can be seen that if quantitative evaluation using artificial intelligence is conducted in the qualitative evaluation item of ultrasonic equipment, the reliability of ultrasonic equipment can be increased with high accuracy.

초음파 진단기의 설정 파라미터가 영상의 질에 미치는 효과 (Effects of Ultrasonic Scanner Setting Parameters on the Quality of Ultrasonic Images)

  • 양정화;이경성;강관석;팽동국;최민주
    • 한국음향학회지
    • /
    • 제27권2호
    • /
    • pp.57-65
    • /
    • 2008
  • 초음파 진단기의 설정은 영상의 질에 영향을 준다. sonographer는 최적의 영상을 얻기 위해 초음파 영상의 질에 영향을 주는 설정 변수에 대한 효과를 이해해야 한다. 본 연구에서는 4가지 대표적인 영상 조절 변수 즉 TGC (Time Gain Control), 이득 (Gain), 주파수 (Frequency), DR (Dynamic Range)를 고려하였다. 초음파 영상의 질은 LCS (Law Contrast Sensitivity) 관점에서 정량적으로 비친 평가하였다. 실험은 임상용 초음파 진단기 (SA-9000 PRIME, Medison, Korea)를 사용하여 초음파 평가 팬텀 (539, ATS, USA)의 LCS 타겟을 영상화하였다. 영상 조절 변수의 설정을 변화하면서, 각 설정에 대한, 6개의 LCS 영상 (+15 dB, +C dB, +3 dB, -3 dB, -6 dB, -15 dB)을 취득하고, 영상에 대한 LCS픽셀 값을 계산하였다. 실험결과 TGC가 최대, Gain은 중간에서 최대사이, 주파수가 Pen모드, DR이 40-66 dB일 때 타겟 영상 (LCS)의 평균 픽셀 값이 높았다. 모든 타겟 영상에서 DR이 40 dB일 때에 LCS가 좋은 영상을 얻었다. 본 결과는 임상에서 잘 발견되는 solid lesion (+15, +6, +3 dB 타겟과 유사) 또는 cystic lesion (-15, -6, -3 dB 타겟과 비슷)이 있는 mass 평가 시 적절한 영상조절 변수 설정에 유용한 정보를 제공할 것으로 기대된다.

초음파검사 시 기존 초음파젤과 비교한 손소독제의 유용성 연구 (A Study on the Effectiveness of Hand Sanitizer compared to Conventional Ultrasound Gel during Ultrasound Examination)

  • 서선열;이진옥;김영란
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.957-964
    • /
    • 2023
  • 본 연구는 시중에 판매되고 있는 다양한 성분과 제형의 손 소독제들을 전파 매질로 활용하여 초음파 검사를 진행한 후 획득한 영상을 평가·비교하여 기존의 초음파 젤의 대체 가능성을 확인하고자 하였다. 연구 방법으로는 점도가 낮은 liquid type을 제외한 gel type, cream type, foam type의 제형의 제품들을 선정해 에탄올 62% gel type 1개와 cream type 1개, 벤잘코늄 염화물 0.066% cream type 1개와 foam type 1개를 각각 초음파 매질로 사용하여, 축방향 & 측방향 분해능, 투과심도, probe와 phantom 사이의 공기층 형성유무에 관한 영상 평가를 진행하였다. 그 결과, 축방향 & 측방향 분해능 평가와 투과심도 평가에서 4개 실험군 모두 평가 기준에 적합한 결과가 나왔다. 그러나 foam type의 경우 분해능과 투과심도의 평가 기준에는 적합하지만 영상 평가 시 관찰 중심부를 제외한 양 측면부에서 어두운 음영으로 나타났다. 해당 실험을 통해 foam type을 제외한 나머지 3종의 손 소독제는 초음파 젤을 대체할 수 있을 것으로 사료된다.

원호형 선배열 트랜스듀서를 이용한 빈사-투과형 역산란 초음파 토모그래피 (Reflection - Transmission Type Inverse Scattering Ultrasonic Computed Tomography Using Cirucular Arc Linear Array Transducers)

  • 김정순;하강열;산전황;김무준
    • 한국음향학회지
    • /
    • 제23권4호
    • /
    • pp.268-273
    • /
    • 2004
  • 본 연구에서는 원호의 내부벽면에 1열로 배열된 어레이 트랜스듀서를 이용한 반사-투과형 생체진단용 역산란 초음파 단층화상법을 제안하였다. 제안된 방법에서는 대상 물체의 배면에 반사판을 배치하여 경면효과를 이용하였고, 유한 대역을 갖는 펄스파를 송신파로 사용하여 다중 주파수 성분을 이용함으로써 데이터 관측 범위를 줄일 수 있었다. 제안된 방법의 성능 평가를 위하여 컴퓨터 시뮬레이션을 이용한 모의 생체 조직에 대한 유효성을 검토한 격과, 트랜스듀서군의 송수신 각도 범위가 30도로 극히 좁은 범위로 제한되었음에도 불구하고 정량적인 화상재현이 가능함을 확인할 수 있다.

Implementation of an Ultrasound Elasticity Imaging System

  • Cho Gae-Young;Yoon Ra-Young;Park Jeong-Man;Kwon Sung-Jae;Ahn Young-Bok;Bae Moo-Ho;Jeong Mok-Kun
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권3호
    • /
    • pp.117-124
    • /
    • 2006
  • Recently, active research has been going on to measure the elastic modulus of human soft tissue with medical ultrasound imaging systems for the purpose of diagnosing cancers or tumors which have been difficult to detect with conventional B-mode imaging techniques. In this paper, a real-time ultrasonic elasticity imaging system is implemented in software on a Pentium processor-based ultrasonic diagnostic imaging system. Soft tissue is subjected to external vibration, and the resulting tissue displacements change the phase of received echoes, which is in turn used to estimate tissue elasticity. It was confirmed from experiment with a phantom that the implemented elasticity imaging system could differentiate between soft and hard regions, where the latter is twice harder than the former, while operating at an adequate frame rate of 20 frames/s.

의료용 초음파 영상시스템을 위한 Wavelet 과 Subband Filter Bank 에 기반한 새로운 탐침 파형의 설계: A Simulation Study (A New Design of the Interrogating Waves for Medical Ultrasonic Imaging Based on Wavelets and Subband Filter Banks: A Simulation Study)

  • 양윤석
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.431-438
    • /
    • 2004
  • 의료용 초음파 영상 장비는 안전하면서도 사용이 편리할 뿐 아니라, 인체 내부의 구조적 영상을 포함하여 혈류나 내부 장기의 움직임에 이르기까지 진단을 위한 다양한 정보를 제공한다. 뿐만 아니라 조직 특성화 영상에서는 반사된 초음파 신호로부터 생체 조직의 물리적인 특성을 파악하여 진단에 활용하기도 한다. 하지만 영상의 획득을 위해 사용하는 탐침용 초음파 펄스 신호는 인체내부를 거쳐 그 흔적이 반사신호에 남게 되고, 이는 영상의 화질 저하로 이어져 미세한 조직이나 인접한 부분의 세밀한 관찰이 어려운 단점이 있다. 이를 해결하기 위한 다양한 연구가 시도 되었으나, 한정된 반사 신호로부터 탐침 펄스의 영향을 제거하고 매질의 특성을 복원하는 데에는 어려움이 있었다. 본 연구에서는 wavelet 과 subband filter bank 에 기반한 새로운 탐침용 초음파 펄스 및 그에 따른 영상획득 방법을 제안하였다. Perfect reconstruction (PR) 조건을 만족하는 일련의 wavelet filter 세트를 초음파 펄스로 구현하여 탐침에 사용하고, 반사되어온 신호를 적절히 재조합 하면 탐침 펄스의 영향이 배제되어, 매질의 세밀한 특성을 복원한 영상을 얻게 된다. 이는 조직 특성화 영상등을 위해 중요한 정보가 된다. 검증을 위해 2종류 (A-mode 와 B-mode) 의 초음파 영상 시뮬레이션에서, 제안된 방법으로 영상을 획득하였다. 그 결과, 탐침 대상의 주파수 특성을 복원할 수 있었으며, 기존의 방법에 비해 향상된 화질의 초음파 영상을 얻을 수 있었다.

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.122-125
    • /
    • 2004
  • 폐, 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range 3 cm${\sim}$3 m), Computer(RS232C), Servo Motor (Torque 2.3 Kg)등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램 하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터 간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터 간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}$1% 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 2.34 ${\times}$ 10-4 초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정 간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정 간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}$1%이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34 ${\times}$ 10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.

  • PDF

조직등가팬텀을 이용한 임상초음파 영상의 질에 관한 연구 - 제주도 내 병원을 중심으로 - (A Study on the Quality of Image of Ultrasound Using the Tissue-mimicking Phantom - in some hospitals jeju province)

  • 양정화;이경성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권2호
    • /
    • pp.63-69
    • /
    • 2006
  • 초음파 영상의 질은 진단에 많은 영향을 끼친다. 양질의 영상이 항상 일정하게 유지되기 위해서는 QA(Quality Assurance) 프로그램을 가지고 주기적인 관리가 이루어져야 할 것이다. 본 논문은 임상에서의 QA 상황을 파악하는 첫 번째 단계로 실제 병원의 초음파 영상의 질을 살펴보고자 하였다. 이를 위해 인간의 생체등가물질로 된 팬텀을 이용하여 정상 환자를 스캔할 때와 같은 기준 값에서 가상의 낭포 및 고반사 신호의 구조물들이 몇 개가 보이는지 convex probe와 linear probe를 측정하여 비교하였다. convex probe에서는 정상 간과 비슷한 0.5 dB에서 vertical group, cystic masses, high contrast masses에서는 대부분 잘 보였으며 지방간과 비슷한 조건인 0.7 dB에서는 vertical group이 중간레벨에서, cystic masses와 high contrast masses에서는 대체로 모두 잘 보였다. linear probe에서의 vertical group은 0.5 dB에서 중간레벨만 잘 보였고 cystic masses와 high contrast masses는 두 개에서 네 개 보이는 것들이 고루 분포되었으나 하나도 보이는 않는 경우가 11건수나 되었다. 0.7 dB에서는 vertical group이 6개 이하가 보이는 것이 대부분 이었고 cystic masses와 high contrast masses에서도 두개에서 네 개 보이는 것들이 고루 분포되었고 하나도 보이는 않는 경우도 40건 있었다. 이로서 지방간과 같은 조건하에서는 linear probe의 영상의 질이 대체로 좋지 않으므로 기준 설정 및 물리적인 조건들을 검사 시에 잘 조정하거나 probe의 교체가 필요하다고 판단된다. 많은 병원에서 초음파 장비를 잘 관리하고 있다고 하지만, 영상의 질은 아직도 미흡한 것을 알 수 있다. 초음파 장비의 설치에서부터 영상의 질을 평가하고 지속적이고 정기적인 관리와 평가가 이루어질 수 있는 프로그램이 필요하겠다.

  • PDF

촉각 정보를 이용한 이동로봇의 원격제어 (Remote Control of a Mobile Robot using Haptic Device)

  • 권용태;강희준;노영식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.737-741
    • /
    • 2004
  • A mobile robot system is developed which is remotely controlled by a haptic master called ‘PHANTOM’. The mobile robot has 4 ultrasonic sensors and single CCD camera which detects the distance from a mobile robot to obstacles in the environment and sends this information to a haptic master. For more convenient remote control, haptic rendering process is performed like viscosity forces and obstacle avoidance forces. In order to show the effectiveness of the developed system, we experiment that the mobile robot runs through the maze and the time is checked to complete the path of the maze with/without the haptic information. Through this repeated experiments, haptic information proves to be useful for remote control of a mobile robot.

  • PDF