• Title/Summary/Keyword: Ultrasonic Experiment

Search Result 430, Processing Time 0.023 seconds

THE MEASUREMENT OF FAT THICKNESS IN LIVE CATTLE WITH AN ULTRASONIC DEVICE AS A PREDICTOR OF CARCASS COMPOSITION

  • Mitsuhashi, T.;Mitsumoto, M.;Yamashita, Y.;Ozawa, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.3 no.4
    • /
    • pp.263-267
    • /
    • 1990
  • The fat thicknesses of twenty-eight Japanese Black beef steers were measured with an ultrasonic device at eleven points on the cattle prior to slaughter and side dissection. The relation between live fat thickness and both weight and percentage of fat and lean in the carcass was examined. Fat thickness obtained from nine points of the chest, flank and rump regions was found to relate significantly (P<0.01) to both weight and percentage of fat. However, shoulder fat thickness measurements were not significantly related to the weight or percentage of fat or lean in the carcass. Addition of live fat thickness to animal age or live weight as an independent variable markedly improved the precision of multiple regression equations for predicting weight of fat and lean, and percentage of fat. In predicting the percentage of lean, both animal age and body weight were not employed in the multiple regression equation. The residual standard deviation for predicting percentage of fat and lean were 1.93 and 1.87, respectively. The ultrasonic measurement of fat thickness if supposed to be useful to the prediction of carcass composition of beef cattle.

The Effect of Ultrasonic Impact Treatment(UIT) for Fatigue Life of Weldment (Ultrasonic Impact Treatment(UIT)효과가 용접재의 피로수명에 미치는 영향)

  • Song, Jun-Hyouk;Lee, Hyun-Woo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.6
    • /
    • pp.38-45
    • /
    • 2010
  • Welding structures are designed to endure its expected life. The most important factors are life. Especially on welded structure, fatigue strength is critical. So this study performed a research on Box and T shape weldment specimen to examine the influence of welding type. In this experiment, the results indicate Box shape was available in more than T shape. Fatigue tests were performed to evaluate the fatigue strength of the both as-welded and statically pre-loaded specimens by 3 point bending load. Fatigue life can be improved by using Ultrasonic Impact Treatment(UIT) effect. Ultrasonic Impact Treatment(UIT) is excellent for eliminating the tensile residual stresses and generating compressive residual stresses which elevate fatigue strength of welded structures. Also, this shows that welding part has better fatigue life and welding was performed well. In this study, to evaluate the Ultrasonic Impact Treatment(UIT) effect, for welding structure, the experiment was conducted at various levels of stress range between 100MPa and 500MPa. From the test results, it was indicated that fatigue performance was improving by Ultrasonic Impact Treatment(UIT)

Vibration Analysis of ultrasonic Horn for Flip-Chip Bonding (플립칩 접합용 초음파 혼의 진동해석)

  • Kim, Il-Kwang;Hong, Sang-Hyuk;Lee, Soo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.364-367
    • /
    • 2008
  • Finite element model and the basic experimental method have been developed to help the design of the transverse ultrasonic horn for flip-chip bonding. With two types of design the horn performance and ultrasonic characteristics are verified by using laser vibrometer. These analysis and experiment results can be the fundamental data for ultrasonic horn design considering the vibration modes and performance.

  • PDF

An Experiment Study on the Combustion Characteristics with BD20 according to Ultrasonic Energy Irradiation Duration and Injection Delay in a Diesel Engine (초음파 에너지 조사 시간과 분사지연에 따른 BD20의 디젤기관 연소특성에 관한 실험 연구)

  • Im, Seok-Yeon;Lee, Ho-Gil;Ryu, Jeong-In
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.38-46
    • /
    • 2008
  • An object of this study is to understand the correlation between the characteristics of an engine performance and combustion characteristics, applying BD20 fuel reformed by ultrasonic energy irradiation to diesel engines. Before conducting the main experiment, an experiment was performed to determine the optimum injection timimg of reformed BD20 by ultrasonic energy irradiation. To control the duration of the ultrasonic energy irradiation, the capacity of an ultrasonic energy fuel supply system was tested with 550cc and 1100cc chambers. As the result of the analysis of the regular BD20 and reformed BD20 by ultrasonic energy irradiation, the BSFC and the Power of the reformed BD20 was improved 3% and 6%, respectively compared to those of non-irradiated BD20. When the fuel injection timing was delayed by $5^{\circ}$, the engine power was improved by 3%, and the BSFC was improved by 2%. The maximum cylinder pressure of reformed BD20 was improved by a maximum of 6% in comparison to that of regular BD20, and demonstrated a synergistic effect of 3% by delaying the injection timing $5^{\circ}$.

Modeling of Ultrasonic Testing in Butt Joint by Ray Tracing

  • Nam, Young-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.441-447
    • /
    • 2001
  • Ultrasonic wave generation and propagation were modeled to simulate an ultrasonic test. A ray model was used for the modeling. Actual sound pressure distribution of the incident wave from an angle probe was analyzed using an ultrasonic visualization method to incorporate the actual sound pressure distribution in the model. In this method, the sound pressure was expressed by the density of rays and the reflection coefficient of ultrasonic beams. Reflection and mode conversion of rays were computed by the Snells law. Simulation programs for the problem of ultrasonic testing of a butt joint are built using this ray modeling. Simulation results for ultrasonic wave scattering from a defect and A-scan display in ultrasonic testing agreed with the actual experiment results.

  • PDF

Atomization Characteristics Experiment of Hole Type Nozzle for the Reduction of Harmful Exhausted Gas (유해배기가스 저감을 위한 Hole형 노즐의 미립화 특성실험)

  • Chung, Jin-Do;Yu, Byoung-Gu
    • Journal of ILASS-Korea
    • /
    • v.2 no.3
    • /
    • pp.17-24
    • /
    • 1997
  • A simplified experiment was performed to figure out the atomization characteristics of rice-bran oil which it is highly viscous liquid by applying ultrasonic energy. A spray system, an ultrasonic system, and three kinds of hole-type nozzles(hole diameter: 0.31, 0.34, 0.37mm) were manufactured. To investigate the effects of ultrasonic energy on the atomization of a highly viscous liquid, a phase doppler particle analyzer was used for measurement and calculation of spray droplets data. Nozzle opening pressures were chosen of 3 levels, i.e, 16, 20, and 24MPa. As a result, it could be concluded that the ultrasonic energy was effective to improve the spray atomization when it applied to the fuel by means of 3 different nozzles because of the effects of the liquid fuel cavitation and relaxation between molecules caused by ultrasonic energy. The improvement rate of the spray atomization by the ultrasonic method compared with the conventional spray increased about 15% in the case of hole type nozzles. By increasing of the nozzle opening pressure and decreasing of the hole diameter, the atomization of spray droplets was improved.

  • PDF

Root surface roughness following mechanical instrumentation in vivo and in vitro SEM study (기구조작후 치근표면의 조도에 관한 연구; 주사전자현미경적 in vivo 및 in vitro 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.809-822
    • /
    • 1998
  • Adequate root preparation in the treatment of periodontal disease often involves mechanical instrumentation to remove plaque, calculus perhaps contaminated cementum. Although meticulous scaling and root planing may remove some cementum, the use of aggressive root planing to remove cementum does not appear warranted. So ultrasonic device and rotary instrument appear to be replacing hand instrument. But it is not clear those instruments make smooth root surface as hand instrument. The roghness of the root surface were evaluate with SEM following instrumentation with Gracey curette, Perio Clean and piezo ultrasonic device(Setlec) with various tip. 20 extracted teeth were used in vitro experiment, and 9 teeth of a patient destined for extraction for periodontal reasons were utilized in vivo experiment. It was demonstrated that hand curette created the smoothest surface, while diamond tip tended to roughen the root surface. But the hand curette, Perio Clean, and piezo ultasonic device with scaler tip tend to remove cementum completely. Piezo ultrasonic device with curette-like tip made the desirable smooth surface with partial removal of cementum.

  • PDF

A Study on the Performance of EFI Engine Used Ultrasonic Energy Adding Fuel system(II) -Attaching Importance to the Fuel Spray- (초음파연료공급창치를 이용한 EFI기관의 성능에 관한 연구(II) -연료 분사를 중심으로-)

  • 윤면근;류정인
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.80-86
    • /
    • 1997
  • This experiment was undertaken to investigate spray characteristics of the conventional injection system and the ultrasonic energy added injection system. Sauter mean diameter was measured under the variation of injection pressure and the spray distance. To measure the droplet size, we used the Malvern system 2600C. The spray angle and mass distribution were analyzed to the CCD camera and the patternater. After experiment, it was found that the ultrasonic energy added injection system had smaller Sauter mean diameter of droplet, wider mass distribution and wider spray angle than the conventional injection system had.

  • PDF

Tightly-Coupled GPS/INS/Ultrasonic-Speedometer/Barometer Integrated Positioning for GPS-Denied Environments

  • Choi, Bu-Sung;Yoo, Won-Jae;Kim, Lawoo;Lee, Yu-Dam;Lee, Hyung-Keun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.4
    • /
    • pp.387-395
    • /
    • 2020
  • Accuracy of an integrated Global Positioning System (GPS) / Inertial Navigation System (INS) relies heavily on the visibility of GPS satellites. Especially, its accuracy is dramatically degraded in urban canyon due to signal obstructions due to large structures. In this paper, we propose a new integrated positioning system that effectively combines INS, GPS, ultrasonic sensor, and barometer in GPS-denied environments. In the proposed system, the ultrasonic sensor provides velocity information along the forward direction of moving vehicle. The barometer output provides height information compensated for the pressure variation due to fast vehicle movements. To evaluate the performance of the proposed system, an experiment was carried out by mounting the proposed system on a test car. By the experiment result, it was confirmed that the proposed system bears good potential to maintain positioning accuracy in harsh urban environments.

Partial Discharge Ultrasonic Analysis for Generator Stator Windings

  • Yang, Yong-Ming;Chen, Xue-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.670-676
    • /
    • 2014
  • The objective of this research is to utilize the ultrasonic method to analyze the property of partial discharge (PD) which is generated by the winding of the insulation stator in the generator. Therefore, a PD measurement system is built based on ultrasonic and virtual instruments. Three types of PD models (internal PD model, surface PD model and slot PD model) have been constructed. With the analysis of these experimental results, this research has identified the ultrasonic signals of the discharges which were produced by three types of PD models. This analysis shows the different features among these PD types. Both the time domain and frequency domain of the ultrasonic signals are obviously different. In addition, an experiment based on a large rotating machine has been done to analyze ultrasonic noises. The result indicates that the ultrasonic noises can be wiped off by the filters and algorithms. The application of this system is convenient for the detection of early signs of insulation failure, which is an effective method for diagnosis of insulation faults.