Abstract
This experiment was undertaken to investigate spray characteristics of the conventional injection system and the ultrasonic energy added injection system. Sauter mean diameter was measured under the variation of injection pressure and the spray distance. To measure the droplet size, we used the Malvern system 2600C. The spray angle and mass distribution were analyzed to the CCD camera and the patternater. After experiment, it was found that the ultrasonic energy added injection system had smaller Sauter mean diameter of droplet, wider mass distribution and wider spray angle than the conventional injection system had.